Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Abstract
One hemiplegic patient with a dropfoot was chronically implanted with a cuff on the sural nerve, and recordings were made regularly during a period of two years. The results showed that the human sural nerve responded in a similar way to mechanical inputs applied on the skin, as the tibial nerve did in cats (M.K. Haugland, et al., ibid., vol. 2, p. 18-28, 1994), indicating that previous experimental systems using natural sensory feedback for closed-loop FNS are possible to adapt to humans. During walking, the recorded nerve signal modulated strongly and gave a clearly detectable response at foot contact and a silent period when the foot was in the air through the swing phase of the walking cycle. A portable system was built that used the recorded signal to control a peroneal stimulator to correct for footdrop. There were two reasons for this: first, to show in a relatively simple system the possibility of solving the practical problems involved in recording nerve activity during stimulation and second, to remove the external heel switch used in existing systems for footdrop correction, thereby making it possible to use such systems without footwear and preparing it to be a totally implantable system. The method for removing artifacts, as developed in animal experiments, was adapted to provide usable nerve signals while stimulating the ankle dorsiflexor muscles.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
FES has clinical applications for activation of lower extremity motion.
“for activation of lower extremity motion”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Haugland and Sinkjaer, 1995
Surface electrodes are used in FES systems for correction of foot drop in hemiplegic patients.
“They are also used in more sophisticated FES systems for correction of foot drop in hemiplegic patients”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Haugland and Sinkjaer, 1995
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343 · see citing works
A review of portable FES-based neural orthoses for the correction of drop foot
Lyons, G. M., Sinkjaer, T., Burridge, J. H., & Wilcox, D. J. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806832 · Cited by 277 · see citing works
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263 · see citing works
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144 · see citing works
Cuff electrodes for long-term recording of natural sensory information
Struijk, J. J., Thomsen, M., Larsen, J. O., & Sinkjaer, T. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765194 · Cited by 97 · see citing works
Raspopovic, S., Carpaneto, J., Udina, E., Navarro, X., & Micera, S. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-17 · Cited by 81 · see citing works
Design of a low-noise preamplifier for nerve cuff electrode recording
Rieger, R., Taylor, J., Demosthenous, A., Donaldson, N., & Langlois, P. J. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.814437 · Cited by 78 · see citing works
Upshaw, B., & Sinkjaer, T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.681183 · Cited by 74 · see citing works
Self-citationMicera, S., Jensen, W., Sepulveda, F., Riso, R. R., & Sinkjaer, T. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930903 · Cited by 58 · see citing works
Very Low-Noise ENG Amplifier System Using CMOS Technology
Rieger, R., Schuettler, M., Pal, D., Clarke, C., Langlois, P., Taylor, J., & Donaldson, N. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.886731 · Cited by 57 · see citing works
Long‐term biocompatibility of implanted polymer‐based intrafascicular electrodes
Lawrence, S. M., Larsen, J. O., Horch, K. W., Riso, R., & Sinkjær, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10303 · Cited by 55 · see citing works
Self-citationSpiral nerve cuff electrode for recordings of respiratory output
Sahin, M., Haxhiu, M. A., Durand, D. M., & Dreshaj, I. A. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.1.317 · Cited by 47 · see citing works
Stable Detection of Movement Intent From Peripheral Nerves: Chronic Study in Dogs
Dweiri, Y. M., Eggers, T. E., Gonzalez-Reyes, L. E., Drain, J., McCallum, G. A., & Durand, D. M. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2607520 · Cited by 44 · see citing works
Nielsen, T. N., Sevcencu, C., & Struijk, J. J. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278479 · Cited by 15 · see citing works
- Authors
- Haugland, M. K., & Sinkjaer, T.
- Affiliations
- Aalborg University (DK)
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1995
- Volume
- 3
- Issue
- 4
- Pages
- 307-317
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2110760239
- Cited by
- 168
- References
- 0
- Citations by year
- 2024: 1 · 2022: 4 · 2021: 5 · 2020: 2 · 2019: 5 · 2018: 2 · 2017: 4 · 2016: 4 · 2015: 4 · 2014: 2 · 2013: 11 · 2012: 5
- FWCI
- 1.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Rehabilitation Engineering (publishedVersion)
- VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- foot drop, sural nerve, closed-loop neuromodulation, hemiplegia, ankle dorsiflexor muscles, gait, artifact removal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review