Improvement of resolution in measurement of electrocardiogram RR intervals by interpolation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The measurement of successive RR intervals, obtained from the electrocardiogram (ECG), is the basis of any subsequent method for the assessment of variations in heart rate, for example using intervalograms, histograms, trend curves, spectral analysis, etc. The accuracy of measurement directly depends on the sampling rate used for the acquisition of the ECG signal. Depending on specific applications, rates down to 128 Hz are not uncommon. This considerably limits the resolution if RR interval data are to be derived. Interpolation is often employed for solving problems of this type. Linear, cubic and spline interpolations, obtained directly from the MATLAB software product, were applied and compared for the purpose of RR interval measurement. The cubic method was found to combine the improvement of resolution (+/-1 ms) at sampling rates successfully down to 100 Hz, with a rapid operating speed. Comparison examples are given with ECG signals acquired with 1000 Hz, 16-bit sampling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bailey, J. J., Berson, A. S., Garson, A., Horan, L. G., Macfarlane, P. W., Mortara, D. W., & Zywietz, C. (1990) · Circulation · doi:10.1161/01.cir.81.2.730 · Cited by 313
Cited by
Amihai, I., & Kozhevnikov, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0102990 · Cited by 173
“the heart rate variability estimations [61,62].”
How the insula speaks to the heart: Cardiac responses to insular stimulation in humans
Chouchou, F., Mauguière, F., Vallayer, O., Catenoix, H., Isnard, J., Montavont, A., Jung, J., Pichot, V., Rheims, S., & Mazzola, L. (2019) · Human Brain Mapping · doi:10.1002/hbm.24548 · Cited by 148
Ellis, R. J., Zhu, B., Koenig, J., Thayer, J. F., & Wang, Y. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/9/1827 · Cited by 85
Béres, S., Holczer, L., & Hejjel, L. (2019) · Measurement Science Review · doi:10.2478/msr-2019-0030 · Cited by 33
Metadata
- Authors
- Daskalov, I., & Christov, I.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1997-06-01
- Volume
- 19
- Issue
- 4
- Pages
- 375-379
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2001204082
- Cited by
- 70
- References
- 1
- FWCI
- 0.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improvement of resolution in measurement of electrocardiogram RR intervals by interpolation. https://app.cochat.ai/papers/10.1016/s1350-4533(96)00067-7
- The paper
- Daskalov, I., & Christov, I. (1997). Improvement of resolution in measurement of electrocardiogram RR intervals by interpolation. Medical Engineering & Physics. https://doi.org/10.1016/s1350-4533(96)00067-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.