An algorithm for detecting the onset of muscle contraction by EMG signal processing
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The Generalized Likelihood Ratio (GLR) test is proposed for estimating the time instant of muscle contraction onset via electromyographic (EMG) signal processing. In contrast to commonly used threshold-based estimation methods, the proposed algorithm proves to be reasonably accurate even for low levels of EMG activity; the improved behaviour of the GLR test comes with just a modest increase in the computational complexity. A set of computer simulation experiments are presented, where the proposed algorithm and two different threshold-based estimators are studied; also, we discuss the results of analysing the EMG recordings of selected proximal muscles of the upper limb in a hemiparetic subject.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
EMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
Reliability of Computerized Surface Electromyography for Determining the Onset of Muscle Activity
Di Fabio, R. P. (1987) · Physical Therapy · doi:10.1093/ptj/67.1.43 · Cited by 278
Graupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205
Cited by
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Self-citationControl of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Self-citationRadebold, A., Cholewicki, J., Panjabi, M. M., & Patel, T. C. (2000) · Spine · doi:10.1097/00007632-200004150-00009 · Cited by 524
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Self-citationTeager–Kaiser energy operator signal conditioning improves EMG onset detection
Solnik, S., Rider, P., Steinweg, K., DeVita, P., & Hortobágyi, T. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1521-8 · Cited by 339
Metadata
- Authors
- Micera, S., Sabatini, A. M., & Dario, P.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1998-04-01
- Volume
- 20
- Issue
- 3
- Pages
- 211-215
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2047562431
- Cited by
- 94
- References
- 5
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor, 232 d)
- iopscience.iop.org/info/page/text-and-data-mining (tdm, 232 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An algorithm for detecting the onset of muscle contraction by EMG signal processing. https://app.cochat.ai/papers/10.1016/s1350-4533(98)00017-4
- The paper
- Micera, S., Sabatini, A. M., & Dario, P. (1998). An algorithm for detecting the onset of muscle contraction by EMG signal processing. Medical Engineering & Physics. https://doi.org/10.1016/s1350-4533(98)00017-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.