Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 255

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Normalisation of EMG amplitude: an evaluation and comparison of old and new methods

Burden, Adrian, Bartlett, Roger·1999·Medical Engineering & Physics

Abstract

The purpose of this study was to evaluate and compare four different methods of normalising the amplitude of electromyograms (EMGs), from the biceps brachii. Five males performed isotonic contractions of the elbow flexors with an external force of 50 N, 100 N, 150 N and 200 N. These were followed by a single isometric maximal voluntary contraction (MVC) and ten isokinetic MVCs at 0.35 rad s(-1) intervals between 0.35 rad s(-1) and 3.50 rad s(-1). The processed EMGs recorded from the isotonic contractions were normalised by expressing them as a percentage of: (i) the mean (Dynamic Mean Method) and (ii) the peak EMG from the same contraction (Dynamic Peak Method), (iii) the EMG from the isometric MVC (Isometric MVC Method), and (iv) the EMG from an isokinetic MVC at the same elbow angle and angular velocity (Isokinetic MVC Method). The root mean square difference (RMSD) between the outputs of the Isokinetic MVC and Dynamic Mean methods was significantly greater (P<0.05) than between the Isokinetic MVC method and the Dynamic Peak and the Isometric MVC methods. The small (10%) difference between the Isokinetic MVC and the Isometric MVC Methods was a consequence, firstly, of the lack of difference in EMG recorded from the isometric and isokinetic MVCs and, secondly, the consistency in EMG over the range of motion and at different angular velocities of isokinetic MVC. We conclude that only the Isometric and Isokinetic MVC methods should be used to normalise the amplitude of EMGs from the biceps brachii.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s1350-4533(99)00054-5

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 255

Metadata

Authors
Burden, A., & Bartlett, R.
Venue
Medical Engineering & Physics
Published
1999-05-01
Volume
21
Issue
4
Pages
247-257
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W2014654425
Cited by
255
References
1
FWCI
2.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Normalisation of EMG amplitude: an evaluation and comparison of old and new methods. https://app.cochat.ai/papers/10.1016/s1350-4533(99)00054-5
The paper
Burden, A., & Bartlett, R. (1999). Normalisation of EMG amplitude: an evaluation and comparison of old and new methods. Medical Engineering & Physics. https://doi.org/10.1016/s1350-4533(99)00054-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.