Decomposition and quantitative analysis of clinical electromyographic signals
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Procedures for the quantitative analysis of clinical electromyographic (EMG) signals detected simultaneously using selective or micro and non-selective or macro electrodes are presented. The procedures first involve the decomposition of the micro signals and then the quantitative analysis of the resulting motor unit action potential trains (MUAPTs) in conjunction with the associated macro signal. The decomposition procedures consist of a series of algorithms that are successively and iteratively applied to resolve a composite micro EMG signal into its constituent MUAPTs. The algorithms involve the detection of motor unit action potentials (MUAPs), MUAP clustering and supervised classification and they use shape and firing pattern information along with data dependent assignment criteria to obtain robust performance across a variety of EMG signals. The accuracy, extent and speed with which a set of 10 representative 20-30 s, concentric needle detected, micro signals could be decomposed are reported and discussed. The decomposition algorithms had a maximum and average error rate of 2.5% and 0.7%, respectively, on average assigned 88.7% of the detected MUAPs and took between 4 to 8 s. Quantitative analysis techniques involving average micro and macro MUAP shapes, the variability of micro MUAPs shapes and motor unit firing patterns are described and results obtained from analysis of the data set used to evaluate the decomposition algorithms are summarized and discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb01338.x · Cited by 88,486
Algorithms for Clustering Data
Sarle, W. S. (1990) · Technometrics · doi:10.1080/00401706.1990.10484648 · Cited by 7,865
Algorithms for clustering data
Flury, B. (1989) · Journal of Statistical Planning and Inference · doi:10.1016/0378-3758(89)90033-5 · Cited by 6,432
A Mathematical Theory of Communications
Shannon, C. E. (1948) · Cited by 2,080
Neuronal Spike Trains and Stochastic Point Processes
Perkel, D. H., Gerstein, G. L., & Moore, G. P. (1967) · Biophysical Journal · doi:10.1016/s0006-3495(67)86596-2 · Cited by 1,489
St??lberg, E., Andreassen, S., Falck, B., Lang, H., Rosenfalck, A., & Trojaborg, W. (1986) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-198610000-00003 · Cited by 239
Macro EMG, a new recording technique.
Stalberg, E. (1980) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.43.6.475 · Cited by 237 · cited 3×
“In contrast, to obtain information regarding the overall size and fibre spatial distribution of a motor unit, or macro information, signals must be acquired with electrodes that have large, non-selective surfaces such as overlying surface electrodes or indwelling macro [22] or conmac [23] electrodes.”
BackgroundMethodQuantitative Motor Unit Potential Analysis
Stålberg, E., Nandedkar, S. D., Sanders, D. B., & Falck, B. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199609000-00004 · Cited by 227
Automatic Decomposition of the Clinical Electromyogram
McGill, K. C., Cummins, K. L., & Dorfman, L. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325562 · Cited by 209 · cited 3×
“[10].”
BackgroundMethodBuchthal, F., & Kamieniecka, Z. (1982) · Muscle & Nerve · doi:10.1002/mus.880050403 · Cited by 200
Cited by
High-yield decomposition of surface EMG signals
Nawab, S. H., Chang, S.-S., & De Luca, C. J. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.11.092 · Cited by 370
Motor unit number estimates in the tibialis anterior muscle of young, old, and very old men
McNeil, C. J., Doherty, T. J., Stashuk, D. W., & Rice, C. L. (2005) · Muscle & Nerve · doi:10.1002/mus.20276 · Cited by 345
Self-citationForced, not voluntary, exercise improves motor function in Parkinson's disease patients
Ridgel, A. L., Vitek, J. L., & Alberts, J. L. (2009) · Neurorehabilitation and neural repair · doi:10.1177/1545968308328726 · Cited by 284
EMG signal decomposition: how can it be accomplished and used?
Stashuk, D. (2001) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00050-x · Cited by 268
Self-citationA Novel Framework Based on FastICA for High Density Surface EMG Decomposition
Chen, M., & Zhou, P. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2412038 · Cited by 260
Age-dependent motor unit remodelling in human limb muscles
Piasecki, M., Ireland, A., Jones, D. A., & McPhee, J. S. (2016) · Biogerontology · doi:10.1007/s10522-015-9627-3 · Cited by 188
“Recording MU potential trains reveals the extent of MU remodelling and the stability of neuromuscular junction transmissions, evidenced in terms of MUP area or amplitudes, distribution of MUP sizes, number of turns, number of phases and jiggle (Stashuk 1999a, b; Abdelmaseeh et al. 2014).”
Piasecki, M., Ireland, A., Piasecki, J., Stashuk, D. W., Swiecicka, A., Rutter, M. K., Jones, D. A., & McPhee, J. S. (2018) · The Journal of Physiology · doi:10.1113/jp275520 · Cited by 181
“All EMG signals were recorded for offline analysis with decomposition-based quantitative electromyography (DQEMG) (Stashuk, 1999).”
MethodSelf-citationGazzoni, M., Farina, D., & Merletti, R. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.01.002 · Cited by 179
Characterizing EMG data using machine-learning tools
Yousefi, J., & Hamilton-Wright, A. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.04.018 · Cited by 158
“The objective of decomposition is to identify the contributions of each MU within the overall acquired signal [15–17].”
BackgroundNeurogenic Changes in the Upper Airway of Patients with Obstructive Sleep Apnea
Saboisky, J. P., Stashuk, D. W., Hamilton-Wright, A., Carusona, A. L., Campana, L. M., Trinder, J., Eckert, D. J., Jordan, A. S., McSharry, D. G., White, D. P., et al. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201106-1058oc · Cited by 119
Self-citationPower, G. A., Allen, M. D., Booth, W. J., Thompson, R. T., Marsh, G. D., & Rice, C. L. (2014) · AGE · doi:10.1007/s11357-014-9642-3 · Cited by 56
Piasecki, M., Ireland, A., Piasecki, J., Degens, H., Stashuk, D. W., Swiecicka, A., Rutter, M. K., Jones, D. A., & McPhee, J. S. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00449 · Cited by 55
Self-citation
Metadata
- Authors
- Stashuk, D. W.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1999-07-01
- Volume
- 21
- Issue
- 6
- Pages
- 389-404
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2025974650
- Cited by
- 202
- References
- 31
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.