Assessing retinal function with the multifocal technique
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
With the multifocal technique, as developed by Erich Sutter and colleagues, scores of focal electroretinogram (ERG) responses can be obtained in a matter of minutes. Although this technique is relatively new, it has already provided insights into the mechanisms of retinal disease. However, because it is new, there also remain questions about how it works and what it measures. This chapter considers some of these insights and some of these questions. The first part (Section 2) describes how the multifocal ERG (mERG) is recorded and considers its relationship to the full-field ERG. The mERG responses are shown to be from relatively local regions of the retina and are comprised of the same components as the full-field ERG. The diagnostic advantage of the mERG as compared to the full-field ERG is also illustrated. In Section 3, the effects of damage to different cell layers of the retina are shown to affect the mERG differently, and these changes are summarized within a conceptual framework. It is argued, for example, that when diseases of the receptor outer segment, like retinitis pigmentosa, result in small, depressed mERG responses, then the damage is, as expected, at the outer segment. However, when these diseases result in mERG responses that are reasonably large but very delayed, then the damage is beyond the outer segment, probably in the outer plexiform layer. The implicit time of the mERG, not amplitude, is the more sensitive measure of damage in degenerative diseases of the receptors. On the other hand, diseases, like glaucoma, which act on the ganglion axon, do not result in easily identified changes to the mERG unless inner retinal damage is involved as well. Inner retinal damage changes the waveform of the mERG and decreases the naso-temporal variation normally observed. Finally, diseases, like diabetes, that act on more than one layer of the retina can have a range of effects. In Section 4, recent work with the monkey mERG is reviewed, with emphasis on the relevance to human diseases. For example, blocking the sodium-based action potentials produced by ganglion and amacrine cells eliminates the naso-temporal variation in the monkey mERG and these altered mERG responses resemble those from some patients with diabetes or glaucoma. Finally, in Section 5 the second-order kernel is described. The presence of a second-order kernel has important implications for understanding the shape of the mERG response (first-order kernel). Full-field simulations of the mERG paradigm illustrate that the first-order kernel is comprised of responses with different waveforms. Further, it is argued that the nonlinear, adaptive mechanisms that produce the second-order kernel are involved in shaping the time course of the response. Patients with large, but abnormally delayed mERG responses (first-order kernel), do not have a detectable second-order kernel. It is speculated that a markedly diminished second-order kernel is diagnostic of outer plexiform layer damage, not inner plexiform layer damage as is commonly assumed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 3,167
The field topography of ERG components in man—I. The photopic luminance response
Sutter, E. E., & Tran, D. (1992) · Vision Research · doi:10.1016/0042-6989(92)90235-b · Cited by 946
Retinitis pigmentosa. The Friedenwald Lecture.
Berson, E. L. (1993) · PubMed · Cited by 730
The photopic negative response of the macaque electroretinogram: reduction by experimental glaucoma.
Viswanáthan, S., Frishman, L. J., Robson, J. G., Harwerth, R. S., & Smith, E. L. (1999) · PubMed · Cited by 417
Sieving, P. A., Murayama, K., & Naarendorp, F. (1994) · Visual Neuroscience · doi:10.1017/s0952523800002431 · Cited by 388
The topography of visual evoked response properties across the visual field
Baseler, H. A., Sutter, E. E., Klein, S. A., & Carney, T. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90114-7 · Cited by 320
A proximal retinal component in the primate photopic ERG a-wave.
Bush, R. A., & Sieving, P. A. (1994) · PubMed · Cited by 280
Multifocal electroretinogram delays reveal local retinal dysfunction in early diabetic retinopathy.
Fortune, B. A., Schneck, M. E., & Adams, A. J. (1999) · PubMed · Cited by 261
Viswanáthan, S., Frishman, L. J., & Robson, J. G. (2000) · PubMed · Cited by 255
Vision Science and its Applications
Howland, H. C., Tyler, C. J., Birch, E. E., & Rosenberg, R. (1996) · Optics and Photonics News · Cited by 222
Cited by
Non-syndromic retinitis pigmentosa
Verbakel, S. K., van Huet, R. A. C., Boon, C. J. F., den Hollander, A. I., Collin, R. W. J., Klaver, C. C. W., Hoyng, C. B., Roepman, R., & Klevering, B. J. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.03.005 · Cited by 973
The severe acute respiratory syndrome coronavirus in tears
Loon, S.-C. (2004) · British Journal of Ophthalmology · doi:10.1136/bjo.2003.035931 · Cited by 342
Primary retinal pathology in multiple sclerosis as detected by optical coherence tomography
Saidha, S., Syc, S. B., Ibrahim, M. A., Eckstein, C., Warner, C. V., Farrell, S. K., Oakley, J. D., Durbin, M. K., Meyer, S. A., Balcer, L. J., et al. (2011) · Brain · doi:10.1093/brain/awq346 · Cited by 333
Radtke, N. D., Aramant, R. B., Petry, H. M., Green, P. T., Pidwell, D. J., & Seiler, M. J. (2008) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2008.04.009 · Cited by 255
A multifocal electroretinogram model predicting the development of diabetic retinopathy
Bearse, M. A., Adams, A. J., Han, Y., Schneck, M. E., Ng, J., Bronson-Castain, K., & Barez, S. (2006) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2006.07.001 · Cited by 247
Multifocal VEP and ganglion cell damage: applications and limitations for the study of glaucoma
Hood, D. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00061-7 · Cited by 245
“The multifocal electroretinogram (mfERG) has failed thus far to reliably detect local ganglion cell damage (see Hood, 2000; Hood et al., 2003b for a review of the mfERG).”
BackgroundSelf-citationThe Multifocal Electroretinogram
Hood, D. C., Odel, J. G., Chen, C. S., & Winn, B. J. (2003) · Journal of Neuro-Ophthalmology · doi:10.1097/00041327-200309000-00008 · Cited by 193
“Furthermore, it is likely that the relatively larger loss of the 2K response as compared with the 1K in BRAO is due to a reduced effect of stray light (7,39).”
BackgroundMethodSelf-citationVisual field defects and neural losses from experimental glaucoma
Harwerth, R. S., Crawford, M. L. J., Frishman, L. J., Viswanathan, S., Smith III, E. L., & Carter-Dawson, L. (2002) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(01)00022-2 · Cited by 172
“Another theoretically valid approach involves the direct measure of glaucomatous neuropathy from the reduced electrical activity generated by the retinal ganglion cell bodies or axons in the electroretinogram (ERG) (Frishman et al., 1996b; Viswanathan and Frishman, 1997; Graham and Klistorner, 1998; Sutter and Bearse,…”
Rodent Models for Glaucoma Retinopathy and Optic Neuropathy
Pang, I.-H., & Clark, A. F. (2007) · Journal of Glaucoma · doi:10.1097/ijg.0b013e3181405d4f · Cited by 162
“The mfERG response, similar to full-field ERG, is contributed predominantly by the bipolar cells and photoreceptor cells with much less contribution from the inner retina.(118,119) It has not been successful to reliably detect local RGC damage.”
BackgroundLocal Diabetic Retinopathy Prediction by Multifocal ERG Delays over 3 Years
Ng, J. S., Bearse, M. A., Schneck, M. E., Barez, S., & Adams, A. J. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-1157 · Cited by 158
Electroretinography in glaucoma diagnosis
Wilsey, L. J., & Fortune, B. (2016) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000000241 · Cited by 113
“There are additional types of ERG recordings based on alternative stimulus and recording paradigms rather than full-field flashes such as the well known pattern reversal ERG (PERG) [22] and multifocal ERG (mfERG) [23], which can also be obtained in a routine clinical setting and offer meaningful objective measurements…”
Background
Metadata
- Authors
- Hood, D. C.
- Venue
- Progress in Retinal and Eye Research
- Publisher
- Elsevier BV
- Published
- 2000-09
- Volume
- 19
- Issue
- 5
- Pages
- 607-646
- ISSN
- 1350-9462 (ISSN-L)
- OpenAlex
- W2098555483
- Cited by
- 481
- References
- 38
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.