The Multifocal Electroretinogram
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
The multifocal electroretinogram (mfERG) technique allows local ERG responses to be recorded simultaneously from many regions of the retina. As in the case of the full-field ERG, the ganglion cells contribute relatively little to the response, which originates largely from the outer retina. The mfERG is particularly valuable in cases in which the fundus appears normal, and it is difficult to distinguish between diseases of the outer retina and diseases of the ganglion cells and/or optic nerve. The mfERG can also help to differentiate among outer retinal diseases, to follow the progression of retinal diseases, and, with the addition of the mfVEP, to differentiate between organic and nonorganic causes of visual loss. However, because the difficulties encountered in recording and analyzing mfERG responses are greater than those involved in full-field ERG testing, mfERG testing is best left to centers with an electrophysiologist familiar with the mfERG test. Although this technique is relatively new and standards are still being developed, centers capable of recording reliable mfERG responses can be found in hundreds of locations around the world.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The field topography of ERG components in man—I. The photopic luminance response
Sutter, E. E., & Tran, D. (1992) · Vision Research · doi:10.1016/0042-6989(92)90235-b · Cited by 946 · cited 3×
“mately equal-sized mfERG responses from individuals with normal retinal function (5).”
BackgroundMethodInfluentialAssessing retinal function with the multifocal technique
Hood, D. C. (2000) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(00)00013-6 · Cited by 481 · cited 9×
“Furthermore, it is likely that the relatively larger loss of the 2K response as compared with the 1K in BRAO is due to a reduced effect of stray light (7,39).”
BackgroundMethodSelf-citationImproved electrode for electroretinography.
Dawson, W. W., Trick, G. L., & Litzkow, C. A. (1979) · PubMed · Cited by 390
Sieving, P. A., Murayama, K., & Naarendorp, F. (1994) · Visual Neuroscience · doi:10.1017/s0952523800002431 · Cited by 388 · cited 1×
“case of the full-field ERG (23,24), the mfERG waveform is largely shaped by bipolar cell activity, together with small contributions from the photoreceptor cells and inner (ama-”
BackgroundA proximal retinal component in the primate photopic ERG a-wave.
Bush, R. A., & Sieving, P. A. (1994) · PubMed · Cited by 280
Guidelines for basic multifocal electroretinography (mfERG)
Marmor, M. F., Hood, D. C., Keating, D., Kondo, M., Seeliger, M. W., & Miyake, Y. (2003) · Documenta Ophthalmologica · doi:10.1023/a:1022591317907 · Cited by 264 · cited 2×
“Thus, the components of the mfERG should never be referred to as the a-wave and b-wave (9).”
BackgroundSelf-citationMultifocal VEP and ganglion cell damage: applications and limitations for the study of glaucoma
Hood, D. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00061-7 · Cited by 245
Self-citationA comparison of the components of the multifocal and full-field ERGs
Hood, D. C., Seiple, W., Holopigian, K., & Greenstein, V. C. (1997) · Visual Neuroscience · doi:10.1017/s0952523800012190 · Cited by 235 · cited 3×
“waves (b-wave and oscillatory potentials) (7,20).”
BackgroundSelf-citationThe optic nerve head component of the human ERG
Sutter, E. E., & Bearse, M. A. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00161-8 · Cited by 171 · cited 2×
“lished (27,28), and there is some evidence that glaucoma can eliminate it (40).”
BackgroundImaging visual function with the multifocal m-sequence technique
Sutter, E. E. (2001) · Vision Research · doi:10.1016/s0042-6989(01)00078-5 · Cited by 158
Cited by
Cuenca, N., Fernández-Sánchez, L., Campello, L., Maneu, V., De la Villa, P., Lax, P., & Pinilla, I. (2014) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2014.07.001 · Cited by 401
“Multifocal VEPs allow identify spatially localized damage and pathologies that may bemissed with a traditional single VEP (Creel, 2012; Hood et al., 2003).”
Influential
Metadata
- Authors
- Hood, D. C., Odel, J. G., Chen, C. S., & Winn, B. J.
- Venue
- Journal of Neuro-Ophthalmology
- Published
- 2003-09
- Volume
- 23
- Issue
- 3
- Pages
- 225-235
- ISSN
- 1070-8022 (ISSN-L)
- OpenAlex
- W1969581472
- Cited by
- 193
- References
- 25
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Multifocal Electroretinogram. https://app.cochat.ai/papers/10.1097/00041327-200309000-00008
- The paper
- Hood, D. C., Odel, J. G., Chen, C. S., & Winn, B. J. (2003). The Multifocal Electroretinogram. Journal of Neuro-Ophthalmology. https://doi.org/10.1097/00041327-200309000-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.