CoChat

Oxygen Distribution and Consumption within the Retina in Vascularised and Avascular Retinas and in Animal Models of Retinal Disease

Yu, Dao-Yi, Cringle, Stephen J. · 2001 · Progress in Retinal and Eye Research

The DOI matches its Crossref record; 85 of the 87 references it cites were found in a registry or an index.

Abstract

Maintenance of an adequate oxygen supply to the retina is critical for retinal function. In species with vascularised retinas, such as man, oxygen is delivered to the retina via a combination of the choroidal vascular bed, which lies immediately behind the retina, and the retinal vasculature, which lies within the inner retina. The high-oxygen demands of the retina, and the relatively sparse nature of the retinal vasculature, are thought to contribute to the particular vulnerability of the retina to vascular disease. A large proportion of retinal blindness is associated with diseases having a vascular component, and disrupted oxygen supply to the retina is likely to be a critical factor. Much attention has therefore been directed at determining the intraretinal oxygen environment in healthy and diseased eyes. Measurements of oxygen levels within the retina have largely been restricted to animal studies in which oxygen sensitive microelectrodes can be used to obtain high-resolution measurements of oxygen tension as a function of retinal depth. Such measurements can immediately identify which retinal layers are supplied with oxygen from the different vascular elements. Additionally, in the outer retinal layers, which do not have any intrinsic oxygen sources, the oxygen distribution can be analysed mathematically to quantify the oxygen consumption rate of specific retinal layers. This has revealed a remarkable heterogeneity of oxygen requirements of different components of the outer retina, with the inner segments of the photoreceptors being the dominant oxygen consumers. Since the presence of the retinal vasculature precludes such a simple quantitative analysis of local oxygen consumption within the inner retina, our understanding of the oxygen needs of the inner retinal components is much less complete. Although several lines of evidence suggest that in the more commonly studied species such as cat, pig, and rat, the oxygen demands of the inner retina as a whole is broadly comparable to that of the outer retina, exactly which cell layers within the inner retina have the most stringent oxygen demands is not known. This may be a critical issue if the cell types most at risk from disrupted oxygen supply are to be identified. This paper reviews our current understanding of the oxygen requirements of the inner and outer retina and presents new data and mathematical models which identify three dominant oxygen-consuming layers in the rat retina. These are the inner segments of the photoreceptors, the outer plexiform layer, and the deeper region of the inner plexiform layer. We also address the intriguing question of how the oxygen requirements of the inner retina are met in those species which naturally have a poorly vascularised, or even totally avascular retina. We present measurements of the intraretinal oxygen distribution in two species of laboratory animal possessing such retinas, the rabbit and the guinea pig. The rabbit has a predominantly avascular retina, with only a narrow band of retinal vasculature, and the guinea pig retina is completely avascular. Both these animals demonstrate species adaptations in which the oxygen requirement of their inner retinas are extremely low when compared to that of their outer retinas. This finding both uncovers a remarkable ability of the inner retina in avascular species to function in a low-oxygen environment, and also highlights the dangers of extrapolating findings from avascular retinas to infer metabolic requirements of vascularised retinas. Different species also demonstrate a marked diversity in the manner in which intraretinal oxygen distribution is influenced by increases in systemic oxygen level. In the vascularised rat retina, the inner retinal oxygen increase is muted by a combination of increased oxygen consumption and a reduction of net oxygen delivery from the retinal circulation. The avascular retina of the guinea pig demonstrated a novel and powerful regulatory mechanism that prevents any dramatic rise in choroidal oxygen levels and keeps retinal oxygen levels within the normal physiological range. In contrast, in the avascular regions of the rabbit retina the choroidal oxygen level passively follows the increase in systemic oxygenation, and there is a dramatic rise in oxygen level in all retinal layers. The presence or absence of oxygen-regulating mechanisms may well reflect important survival strategies for the retina which are not yet understood. Intraretinal oxygen measurements in rat models of retinal disease are also presented. We describe how oxygen distribution across the rat retina is influenced by manipulation of systemic blood pressure. We examine the effect of acute and chronic occlusion of the retinal vasculature, and explore the feasibility of meeting the oxygen needs of the ischemic retina from the choroid. (ABSTRACT TRUNCATED)

Overview

Integrity signals

Registry

Crossref · 10.1016/s1350-9462(00)00027-6

Cites

85 of 85 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 85 references

Research works printed but not linked: 6

  1. Berkowitz, 1996, Adult and newborn rat inner retinal oxygenation during carbogen and 100% oxygen breathing, Invest. Ophthalmol. Vision Sci., 37, 2089
  2. Noell, 1955, Visual cell effects of high oxygen pressures, Fed. Proc., 14, 107
  3. Stefansson, 1980, Light reduces retinal oxygen consumption in vivo, Physiologist, 23, 21
  4. Tsacopoulos, 1979, La physiopathologie de la circulation uveale, J. Fr. Ophtalmol., 2, 135
  5. Valter, 1998, Photoreceptor dystrophy in the RCS rat, Invest. Ophthalmol. Vision Sci., 39, 2427
  6. Yu, 1998, Intraretinal oxygen distribution in urethane-induced retinopathy in rats, Am. J. Physiol., 274, H2009

Cited by

See all 809

Metadata

Authors
Yu, D.-Y., & Cringle, S. J.
Affiliations
Lions Eye Institute (AU)
Corresponding author
Yu, Dao-Yi
Venue
Progress in Retinal and Eye Research
Publisher
Elsevier BV
Published
2001-03
Volume
20
Issue
2
Pages
175-208
ISSN
1350-9462 (ISSN-L)
OpenAlex
W2001507534
Cited by
653
References
87
Citations by year
2026: 20 · 2025: 31 · 2024: 33 · 2023: 36 · 2022: 36 · 2021: 47 · 2020: 44 · 2019: 35 · 2018: 32 · 2017: 36 · 2016: 32 · 2015: 39 · 2014: 26 · 2013: 33 · 2012: 28
FWCI
2.68
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Progress in Retinal and Eye Research (publishedVersion)
  • PubMed (publishedVersion)
  • UWA Profiles and Research Repository (UWA) (submittedVersion)
Topics
  • Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
  • Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
Keywords
retinal oxygen consumption, retinal vasculature, choroid, avascular retina, retinal disease, photoreceptor inner segment, outer plexiform layer, inner plexiform layer, oxygen partial pressure, oxygen consumption rate, mathematical modeling, oxygen microelectrodes, rat retina, cat retina, pig retina
MeSH terms
Animals, Blood Pressure, Oxygen, Oxygen Consumption, Retina, Retinal Diseases, Retinal Vessels, Models, Animal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Oxygen Distribution and Consumption within the Retina in Vascularised and Avascular Retinas and in Animal Models of Retinal Disease. https://app.cochat.ai/papers/10.1016/s1350-9462(00)00027-6
The paper
Yu, D.-Y., & Cringle, S. J. (2001). Oxygen Distribution and Consumption within the Retina in Vascularised and Avascular Retinas and in Animal Models of Retinal Disease. Progress in Retinal and Eye Research. https://doi.org/10.1016/s1350-9462(00)00027-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.