Effects of room furnishings and air speed on particle deposition rates indoors
Open accessThe DOI matches its Crossref record; 17 of the 18 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“There seems little doubt, when taking into account macro air movements related to heating and ventilation, convection, people activity, and even more localised radiative warming due to equipment, the human body and sunshine through windows, a large fraction of respiratory generated particles will be entrained and suspended in air currents and may potentially travel significant distances over time”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [34]
Citations
Cites
An association between air pollution and mortality in six U.S. cities
Dockery, D. W., Pope, C. A., Xu, X., Spengler, J. D., Ware, J. H., Fay, M. E., Ferris, B. G., & Speizer, F. E. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312093292401 · Cited by 8,018
Deposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859
Self-citationMODELING INDOOR PARTICLE DEPOSITION FROM TURBULENT FLOW ONTO SMOOTH SURFACES
K. Lai, A. C., & Nazaroff, W. W. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00536-4 · Cited by 696
Self-citationHealth effects of particulate air pollution: time for reassessment?
Pope, C. A., Bates, D. V., & Raizenne, M. E. (1995) · Environmental Health Perspectives · doi:10.1289/ehp.95103472 · Cited by 528
Long, C. M., Suh, H. H., Catalano, P. J., & Koutrakis, P. (2001) · Environmental Science & Technology · doi:10.1021/es001477d · Cited by 443
Indoor particulate matter of outdoor origin: Importance of size-dependent removal mechanisms
Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es010723y · Cited by 417
Self-citationActivity patterns of Californians: Use of and proximity to indoor pollutant sources
Jenkins, P. L., Phillips, T. J., Mulberg, E. J., & Hui, S. P. (1992) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(92)90402-7 · Cited by 415
Relative contribution of outdoor and indoor particle sources to indoor concentrations
Abt, E., Suh, H. H., Catalano, P., & Koutrakis, P. (2000) · Environmental Science & Technology · doi:10.1021/es990348y · Cited by 411
Vette, A. F., Rea, A. W., Lawless, P. A., Rodes, C. E., Evans, G., Highsmith, V. R., & Sheldon, L. (2001) · Aerosol Science and Technology · doi:10.1080/02786820117903 · Cited by 186
Penetration of Ambient Fine Particles into the Indoor Environment
Mosley, R. B., Greenwell, D. J., Sparks, L. E., Guo, Z., Tucker, W. G., Fortmann, R., & Whitfield, C. (2001) · Aerosol Science and Technology · doi:10.1080/02786820117449 · Cited by 174
Research works printed but not linked: 1
- Thorshauge, 1982, Air velocity fluctuations in the occupied zone of ventilated spaces, ASHRAE Transactions, 88, 753
Cited by
Items 201–300 of 415
Jang, B.-K., Park, K., Lee, S.-Y., Lee, H., Yeon, S. H., Ji, B., Lee, C. H., & Cho, J. S. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18189803 · Cited by 19
“5 decreases by 1/16 due to gravity [13,20].”
BackgroundLee, W.-C., Catalano, P. J., Yoo, J. Y., Park, C. J., & Koutrakis, P. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b03126 · Cited by 22
Bekierski, D., & Kostyrko, K. B. (2021) · Energies · doi:10.3390/en14196230 · Cited by 18
Analysis of vertical movement of particulate matter due to the stack effect in high-rise buildings
Park, S., Yun, C., Lim, H., & Song, D. (2022) · Atmospheric Environment · doi:10.1016/j.atmosenv.2022.119113 · Cited by 19
Yan, S., Wang, L. L., Birnkrant, M. J., Zhai, Z. J., & Miller, S. L. (2022) · Buildings · doi:10.3390/buildings13010102 · Cited by 24
Study of ventilation practices and household characteristics in new California homes.
Piazza, T. A. M. A. (2007) · Cited by 18
Xie, W., Fan, Y., Zhang, X., Tian, G., & Si, P. (2020) · Building Services Engineering Research and Technology · doi:10.1177/0143624420905102 · Cited by 20
“5 penetration coefficient can be calculated by equation (16).”
BackgroundEmissions of ultrafine particles from five types of candles during steady burn conditions
Rasmussen, B. B., Wang, K., Karstoft, J. G., Skov, S. N., Køcks, M., Andersen, C., Wierzbicka, A., Pagels, J., Pedersen, P. B., Glasius, M., et al. (2021) · Indoor Air · doi:10.1111/ina.12800 · Cited by 17
Hiwar, W., King, M., Kharrufa, H., Tidswell, E. L., Fletcher, L. A., & Noakes, C. J. (2022) · Indoor Air · doi:10.1111/ina.13161 · Cited by 18
Stratigou, E., Dusanter, S., de Brito, J. F., & Riffault, V. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107357 · Cited by 19
Mass transport of deposited particles by surface-to-surface contact
McDonagh, A., Sextro, R. G., & Byrne, M. (2012) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2012.05.070 · Cited by 19
“[6] and references therein.”
Self-citationAn experimental study of bioaerosol (1–10 μm) deposition in a ventilated chamber
Lai, A. C. K., Wong, L. T., Mui, K. W., Chan, W. Y., & Yu, H. C. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.02.027 · Cited by 17
Self-citationYuan, Y., Li, S., Chen, T., & Ren, J. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20031890 · Cited by 16
“[22] studied the effect of indoor furnishings on particle deposition at room temperature.”
BackgroundPerformance analysis of a novel air filtration and sterilization PV-Trombe wall
Xie, H., Jia, H., Ji, J., Yu, Q., Meng, H., Li, J., & Mu, Y. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111953 · Cited by 21
A Review of Methods Applied to Study Airborne Biocontaminants inside Aircraft Cabins
Conceição, S. T., Pereira, M. L., & Tribess, A. (2011) · International Journal of Aerospace Engineering · doi:10.1155/2011/824591 · Cited by 16
Hussein, T., Dada, L., Juwhari, H. K., & Faouri, D. (2015) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2015.01.0039 · Cited by 23
“…was previously reported that re-suspension and loss rates of particles (0.5–10 µm in diameter) is linked to the occupancy and the furnishing with an emphasis that coarse particles are the most affected by the occupancy and furnishing scheme (Thatcher and Layton, 1995, Thatcher, Lai et al. , 2002).”
InfluentialLi, W.-W., Paschold, H. W., Morales, H., & Chianelli, J. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(03)00212-7 · Cited by 16
Herkert, N. J., & Hornbuckle, K. C. (2018) · Environmental Science Processes & Impacts · doi:10.1039/c8em00082d · Cited by 15
Geographic differences in inter-individual variability of human exposure to fine particulate matter
Cao, Y., & Frey, H. C. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2011.07.034 · Cited by 15
“The deposition rate depends on particle size source strength and ventilation conditions (He et al., 2005; Thatcher et al., 2002; Lai and Nazaroff, 2000).”
BackgroundSettleable Dust and Bioburden in Portuguese Dwellings
Viegas, C. S. B., Dias, M., Almeida, B., Vicente, E. D., Caetano, L. A., Carolino, E., & Alves, C. A. (2020) · Microorganisms · doi:10.3390/microorganisms8111799 · Cited by 15
“the case of larger particles or diffusion in the case of smaller particles) [45], the amount of furniture indoors [46], the type of ventilation, and air turbulence caused by human activities [47].”
BackgroundMei, X., Gong, G., Su, H., Peng, P., Liu, J., & Xie, H. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.05.038 · Cited by 15
A simplified method for assessing particle deposition rate in aircraft cabins
You, R., & Zhao, B. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.10.046 · Cited by 15
Baron, P. A., Estill, C. F., Deye, G. J., Hein, M. J., Beard, J. K., Larsen, L. D., & Dahlstrom, G. E. (2008) · Aerosol Science and Technology · doi:10.1080/02786820801918605 · Cited by 17
“This increased decay rate of particles in the chamber could have been caused by several factors, including underestimation of particle size by the APS, electrostatic deposition in the chamber, or impaction on fan or other surfaces ( Thatcher et al. 2002 ).”
BackgroundMethodInfluentialLicina, D., & Boor, B. E. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110763 · Cited by 14
Particle and Gas-Phase Evaluation of Air Cleaners Under Indoor Wildfire Smoke Conditions
Stinson, B. W., Laguerre, A., & Gall, E. T. (2024) · ACS ES&T Air · doi:10.1021/acsestair.3c00083 · Cited by 17
Loading Rates of Dust and Bioburden in Dwellings in an Inland City of Southern Europe
Viegas, C. S. B., Dias, M., Almeida, B., Vicente, E. D., Candeias, C., Caetano, L. A., Carolino, E., & Alves, C. A. (2021) · Atmosphere · doi:10.3390/atmos12030378 · Cited by 15
Li, J., Li, C., & Tang, H. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.104255 · Cited by 16
Mak, H. K. C., Chan, D. W. T., Law, L. K. C., & Tung, T. C. W. (2011) · Indoor and Built Environment · doi:10.1177/1420326x11411456 · Cited by 14
Cong, X. C., Zhao, J., Jing, Z., Wang, Q. G., & Ni, P. F. (2018) · Environmental Geochemistry and Health · doi:10.1007/s10653-018-0116-x · Cited by 14
Size-resolved surface deposition and coagulation of indoor particles
Xiao, Y., Lv, Y., Zhou, Y., Liu, H., & Liu, J. (2019) · International Journal of Environmental Health Research · doi:10.1080/09603123.2019.1591351 · Cited by 14
“In other studies of Thatcher et al., deposition rates of particles were compared in a furnished test house and an unfurnished test house and found that room furnishings could greatly increase the S/V ratio (Thatcher et al. 2002).”
BackgroundComputational fluid dynamics investigation of particle intake for nasal breathing by a moving body
Tao, Y., Yang, W. H., Ito, K., & Inthavong, K. (2019) · Experimental and Computational Multiphase Flow · doi:10.1007/s42757-019-0014-1 · Cited by 14
Blower-door estimates of PM 2.5 deposition rates and penetration factors in an idealized room
Lai, Y., Ridley, I. A., & Brimblecombe, P. (2020) · Indoor and Built Environment · doi:10.1177/1420326x20944427 · Cited by 16
Effects of near-wall heat source on particle deposition
Chen, X., Li, A., & Gao, R. (2012) · Building Simulation · doi:10.1007/s12273-012-0078-3 · Cited by 14
“Experiments were performed in an isolated room using four different airflow patterns by Thatcher et al. (2002), which revealed that increasing the mean air speed increased the deposition rate for all particle sizes studied by factors ranging from 1.3 to 2.4 with larger particles exhibiting greater…”
MethodInfluentialParticle Deposition and Decay in a Chamber and the Implications to Exposure Assessment
Lai, A. C. K. (2006) · Water Air & Soil Pollution · doi:10.1007/s11270-006-9141-y · Cited by 14
“particle loss rate, probably because of the relatively simple procedures and apparatus required (Xu et al., 1994; Fogh et al., 1997; Abadie et al., 2001; Thatcher et al., 2002, Lai, 2002) or the indoor-outdoor concentration relationship ( ¨”
MethodSelf-citationBhangar, S., Brooks, B., Firek, B., Licina, D., Tang, X., Morowitz, M. J., Banfield, J. F., & Nazaroff, W. W. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.06.020 · Cited by 13
“deposition loss rate coefficients for submicron particles [26].”
BackgroundSelf-citationWu, C.-C., Wang, W., Bao, L., Shi, L., Tao, S., & Zeng, E. Y. (2019) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2018.12.107 · Cited by 13
“1―2 μm are often categorized as belonging to the accumulation mode, within which greater-sized particles have higher deposition loss-rate coefficients, which can be enhanced upon mixing with air [33].”
BackgroundJones, R. M., & Nicas, M. (2009) · Aerosol Science and Technology · doi:10.1080/02786820903036322 · Cited by 13
“Thatcher et al. (2002) released polydispersed particles into, alternatively, a bare, carpeted, and fully furnished room, and measured the concentration evolution of particles with 0.5 < da < 10 µm: The rate of particle loss from air increased with furnishing level and particle size.”
BackgroundInfluentialRisk modeling for ASHRAE Standard 241-2023 — Control of infectious aerosols
Jones, B., Iddon, C. R., Zaatari, M., Wargocki, P. L., & Bruns, R. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113318 · Cited by 17
Kong, M., Li, L., Eilts, S. M., Li, L., Hogan, C. J., & Pope, Z. (2022) · ACS ES&T Engineering · doi:10.1021/acsestengg.1c00321 · Cited by 12
“Droplets in this size range evaporate upon dispersion into indoor environments,(17,18) yielding micrometer scale aerosol particles with lifetimes in the air which are tens of minutes-to-hours.(19) Such particles are easily dispersed throughout the entire indoor space where they originate and can contribute to infectio…”
BackgroundLi, L., He, R., Kong, M., Eilts, S. M., Hong, J., Hogan, C. J., & Pope, Z. (2022) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2022.106048 · Cited by 12
Investigation of Suspended and Settled Particulate Matter in Indoor Air"
Eštoková, A., & Stevulov, N. (2012) · InTech eBooks · doi:10.5772/46130 · Cited by 14
“In addition, wet processes such as cleaning, washing, drying and ironing increase relative humidity which can lead to variations in particle size distribution [20].”
A Test Chamber Investigation of the Effect of Charging on Aerosol Deposition on Indoor Surfaces
Din, T. M. H. U., McGrath, J. A., & Byrne, M. A. (2020) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2020.03.0094 · Cited by 12
“Thatcher et al. (2002) studied the effect of furnishings and air speeds on the exposure and deposition of aerosols indoors using a room with different furnishing and air speed levels.”
Particle inhalability of a standing mannequin with large airways in a ventilated room
Azhdari, M., Tavakol, M. M., & Ahmadi, G. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104858 · Cited by 12
Saber, E. M., & Bazargan, M. (2011) · International Journal of Environmental Science and Technology · doi:10.1007/bf03326259 · Cited by 12
“The deposition model of Lai and Nazaroff (2000) has been widely applied and further developed in several studies (Thatcher et al., 2002; Lai, 2005; Lai and Nazaroff, 2005; Gao and Niu, 2007; Zhao and Wu, 2007).”
MethodINDOOR AND OUTDOOR AEROSOL PARTICLE SIZE CHARACTERIZATION IN HELSINKI
Hussein, T. (2005) · Työväentutkimus Vuosikirja · Cited by 13
Kriegel, M., Hartmann, A., Buchholz, U., Seifried, J., Baumgarte, S., & Gastmeier, P. (2021) · medRxiv · doi:10.1101/2021.11.04.21265910 · Cited by 12
Evaluation of human walking-induced resuspension of bacteria on different flooring materials
Yang, S. Y., Zhang, H., Hsiao, T.-C., Ferro, A. R., & Lai, A. C. K. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110218 · Cited by 12
Self-citationRelationship between Exhaled Aerosol and Carbon Dioxide Emission Across Respiratory Activities
Moseley, B., Archer, J., Orton, C. M., Symons, H. E., Watson, N. A., Saccente‐Kennedy, B., Philip, K. E. J., Hull, J. H., Costello, D. A. E., Calder, J. D. F., et al. (2024) · Environmental Science & Technology · doi:10.1021/acs.est.4c01717 · Cited by 19
Walther, É., Bogdan, M., & Cohen, R. (2017) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2017.07.090 · Cited by 11
“For stirred environments, air velocities increase the deposition rates as measured by Thatcher et al. (2002).”
MethodZhong, X. L., Fu, S. C., Chan, K. C., & Chao, C. Y. H. (2021) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105802 · Cited by 11
Dry aerosol particle deposition on indoor surfaces: Review of direct measurement techniques
Costa, D., Malet, J., & Géhin, É. (2021) · Aerosol Science and Technology · doi:10.1080/02786826.2021.2013431 · Cited by 11
“Global deposition measurement is intensively used for many different applications, such as sampling tubes (Pui, Romay-Novas, and Liu 1987) and chambers or rooms (Thatcher et al. 2002).”
MethodBramwell, L., Qian, J., Howard-Reed, C., Mondal, S., & Ferro, A. R. (2015) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2015.31 · Cited by 12
Duncan, E. J. S., Kournikakis, B., Ho, J., & Hill, I. D. (2009) · Inhalation Toxicology · doi:10.1080/08958370802412629 · Cited by 13
“Thatcher et al. (2002), in a study on particle deposition rates indoors, observed that increasing the surface area in a room (adding furnishings) increased the deposition loss rate by as much as a factor of 2.6 with the largest increase seen for the smallest particles.”
BackgroundInfluentialParticle Deposition onto People in a Transit Venue
Liljegren, J. C., Brown, D. F., Lunden, M. M., & Silcott, D. B. (2016) · Health Security · doi:10.1089/hs.2016.0010 · Cited by 11
DETERMINATION OF CLEANABILITY OF PLASTIC SURFACES
Pesonen-Leinonen, E. (2005) · Työväentutkimus Vuosikirja · Cited by 11
Gord, J. R., Vigil, C. R., Richards, S., & Bertram, T. H. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110758 · Cited by 11
Transport efficiency and deposition velocity of fluidized spores in ventilation ducts
Krauter, P. A., Biermann, A. H., & Larsen, L. D. (2005) · Aerobiologia · doi:10.1007/s10453-005-9001-z · Cited by 10
Yoshihara, J., Yamanaka, T., Choi, N., Kobayashi, T., Kobayashi, N., & Fujiwara, A. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111911 · Cited by 9
Zhong, Z., Pan, Z., Tang, H., Wang, J., Liu, F., & Wang, J. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110670 · Cited by 12
Ru, L., Ding, L., Deng, S., Li, Q., Zhao, W., Wang, R., Li, J., Lu, Y., & Yao, C. (2023) · Agriculture · doi:10.3390/agriculture13091752 · Cited by 9
“The acceleration of wind speed increases the settling rate of particulate matter [58].”
BackgroundNumerical investigation on particle deposition in a chamber with an attached-wall heat source
Chen, X., Li, A., & Gao, R. (2013) · Indoor and Built Environment · doi:10.1177/1420326x13484773 · Cited by 9
Çetin, Y. E., Avcı, M., & Aydın, O. (2020) · International Journal of Ventilation · doi:10.1080/14733315.2020.1823071 · Cited by 9
“It is stated that turbulence induced by the air velocity has an influential effect on indoor particle deposition (Mosley et al., 2001; Thatcher et al., 2002).”
BackgroundDevelopment of a Residential Integrated Ventilation Controller
Walker, I. S., USDOE Office of Energy Efficiency and Renewable Energy (EERE), California Energy Commission, Sherman, M. H., & Dickerhoff, D. J. (2011) · doi:10.2172/1082205 · Cited by 9
Building removal of particulate pollutant plume during outdoor resuspension event
Qian, J., Tavakoli, B., Goldasteh, I., Ahmadi, G., & Ferro, A. R. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.02.002 · Cited by 9
“Furnishing in indoor environments also increases the particle deposition to indoor surfaces [27], compared to no-furnishing case as simulated in this study.”
MethodWang, Y., Li, A., Fan, X., Shang, L., & Shi-yan, L. (2018) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2018.08.0321 · Cited by 8
“Experimental studies of particle deposition on real indoor surfaces have been extensively performed in small-scale chambers or real houses (Thatcher et al. , 2002; Hamdani et al. , 2008; Chen and Li, 2014).”
InfluentialOgunsola, O. T., Wang, J., & Song, L. (2019) · Science and Technology for the Built Environment · doi:10.1080/23744731.2019.1581501 · Cited by 8
“Studies (Lai 2004; Thatcher et al. 2002) have indicated that for 0.5 to 1.0 mm sized particles (similar particle sizes in our study), the deposition loss coefficients (b) were between 0.09 and 0.15 for bare room surfaces for houses.”
BackgroundInfluentialPereira, M. L., Vilain, R., Leivas, T. P., & Tribess, A. (2012) · Science and Technology for the Built Environment · doi:10.1080/10789669.2012.705572 · Cited by 9
“( 2001 ), the magnitude of the deposition rate within a room is influenced by many factors, including the particle size, shape, and density; surface area, orientation, and roughness; surface-to-air temperature difference; surface particle charge; and air speed.”
BackgroundMonitoring and control of particulate matter in indoor air: A review
Gupta, A. K., & Bhandari, M. (2011) · Journal of Applied and Natural Science · doi:10.31018/jans.v3i1.172 · Cited by 8
Chemical and Physical Properties of Indoor Aerosols
Vu, T. V., & Harrison, R. M. (2019) · Royal Society of Chemistry eBooks · doi:10.1039/9781788016179-00066 · Cited by 11
Patial, S., Nazim, M., Khan, A. A. P., Raizada, P., Singh, P., Hussain, C. M., & Asiri, A. M. (2022) · Journal of Hazardous Materials Advances · doi:10.1016/j.hazadv.2022.100097 · Cited by 18
Chapter 3 Holistic Modeling of Gas and Aerosol Deposition and the Degradation of Cultural Objects
Cole, I. S., Paterson, D. A., & Lau, D. (2007) · Physical techniques in the study of art, archaeology and cultural heritage · doi:10.1016/s1871-1731(07)80005-4 · Cited by 8
Should we use ceiling fans indoors to reduce the risk of transmission of infectious aerosols?
Li, J., Sultan, Z., & Schiavon, S. (2024) · Indoor Environments · doi:10.1016/j.indenv.2024.100039 · Cited by 8
Effectual removal of indoor ultrafine PM using submicron water droplets
Kim, D., Kim, J., & Lee, S. J. (2021) · Journal of Environmental Management · doi:10.1016/j.jenvman.2021.113166 · Cited by 7
Estimating residential air exchange rates in rural Bangladesh using a near field-far field model
Das, D., Moynihan, E. E., Nicas, M., McCollum, E. D., Ahmed, S., Roy, A. D., Chowdhury, N. H., Hanif, A. A. M., Babik, K. R., Baqui, A. H., et al. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108325 · Cited by 7
User Influence on Indoor Aerosol Model Calibration
Hussein, T., Mølgaard, B., & Hämeri, K. J. (2011) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2010.12.0104 · Cited by 7
“…that can be also found in the literature (e.g. Thatcher and Layton, 1995; Jamriska et al., 1999; Kulmala et al., 1999; Abt et al., 2000a, b; Mosley et al., 2001; Thornburg et al., 2001; Riley et al., 2002; Thatcher et al., 2002; Jamriska et al., 2003; Asmi et al., 2004; Schneider et al., 2004).”
BackgroundMethodYu, K., Lee, W. G., Peng, C.-J., Chen, Y., & Shen, W. (2017) · Journal of environmental chemical engineering · doi:10.1016/j.jece.2017.06.024 · Cited by 7
Adeniran, J. A., Araromi, D. O., Yusuf, R. O., Jimoda, L. A., Oke, E. O., & Sonibare, J. A. (2018) · Science and Technology for the Built Environment · doi:10.1080/23744731.2018.1499383 · Cited by 7
“The concentration of indoor air pollutants is strongly influenced by the rate of transport and irreversible deposition onto surfaces in the indoor environment (Crump and Seinfield 1981; Reinmuth-Selzle et al. 2017; Huang et al. 2018; NAzaroff 2018; Thatcher et al. 2002).”
BackgroundEffect of the flow structure on the indoor deposition of particulate matter
Kim, J. J., Kim, H., Kim, J., Lee, I., Kim, H., & Lee, S. J. (2022) · Journal of Visualization · doi:10.1007/s12650-021-00825-4 · Cited by 7
“5 is comparably less affected (Thatcher et al. 2002).”
BackgroundBerman, B. C., Cummings, B. E., Avery, A. M., DeCarlo, P. F., Capps, S. L., & Waring, M. S. (2022) · Indoor Air · doi:10.1111/ina.13075 · Cited by 7
Longevity of size-dependent particle removal performance of do-it-yourself box fan air filters
Pistochini, T., Jaeger, G., Cappa, C. D., & Corsi, R. L. (2024) · Environmental Science Processes & Impacts · doi:10.1039/d4em00406j · Cited by 9
Comparing respiratory aerosol emissions between children and adults during sustained phonation
Rawat, M. S., Agirsoy, M., Senarathna, D., Erath, B. D., Ahmed, T., Mondal, S., & Ferro, A. R. (2023) · Aerosol Science and Technology · doi:10.1080/02786826.2023.2261715 · Cited by 7
Jia, W., Wang, Q., Lung, D. C., Chan, P., Wang, P., Dung, E. C.-H., Didik, T., Choi, G. K.-Y., Tse, H., Wu, Y., et al. (2024) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2024.136388 · Cited by 8
“(2) (4) where is the rate ( ) [11,39]; is the deactivation rate ( ) [13,41]; is the quanta emission rate of the index case ( ); and is the air flowrate from zone i to zone j .”
General particle concentration model and experimental validation for cleanrooms
Zhou, L., Sun, W., Wu, C., Li, H., Zou, Z., & Huang, C. (2020) · Sadhana · doi:10.1007/s12046-020-01398-y · Cited by 6
“1 lm, is caused by Brownian diffusion [30, 31].”
BackgroundHirouchi, J., Takahara, S., Komagamine, H., Kato, N., Matsui, Y., & Yoneda, M. (2021) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac025b · Cited by 6
“The indoor deposition rate was influenced by the furnishings in a house, indoor air circulation achieved by using a fan [21], and surface roughness [5].”
Lu, Y., Yang, X. Y., Lei, E., Zhiwei, F., Li, Y., Liang, C., Shi, Z., & Wang, C. (2023) · Agriculture · doi:10.3390/agriculture13040902 · Cited by 6
Li, L., Pope, Z., Son, Y. J., Eilts, S. M., Hogan, C. J., & Kong, M. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110454 · Cited by 7
Deposition of inhalable particles onto human clothing: A manikin-based chamber study
Jhang, H.-Y., Shen, Y., & Licina, D. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110986 · Cited by 6
Wu, S., Zhu, H., Chen, Y., Qi, C., & Li, G. (2022) · Atmosphere · doi:10.3390/atmos13091408 · Cited by 6
Numerical Simulation of Indoor PM Distribution over the Whole Year by Zonal Model
Zhao, B., Wu, P., Fu, S., Yan, D., Yang, X., Li, X., & Jiang, Y. (2004) · Indoor and Built Environment · doi:10.1177/1420326x04048847 · Cited by 6
Air pollutant penetration through airflow leaks into buildings
Lawrence Berkeley National Lab. (LBNL), B., Liu, D.-L., & USDOE Office of Energy Efficiency and Renewable Energy (EERE) (2002) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/816065 · Cited by 6
Howard-Reed, C., & Polidoro, B. J. (2006) · doi:10.6028/nist.ir.7364 · Cited by 6
“This review included 15 key indoor particle deposition references (Lai et al. 2002; Thatcher et al. 2002; Abadie et al. 2001; Cheng 1997; Fogh et al. 1997; Nomura et al. 1997; Morawska and Jamriska 1996; Byrne et al. 1995; Xu et al. 1994; Chen et al. 1992; Van Dingenen et al. 1989; Okuyama et al. 1986; Offermann et al…”
BackgroundEffect of flow structures on natural ventilation performance in office model
Yoon, G. Y., Lee, S. J., Kwon, H., & Kim, J. J. (2022) · Journal of Visualization · doi:10.1007/s12650-022-00876-1 · Cited by 6
“5 is not (Thatcher et al. 2002).”
Estimated relative potential for airborne SARS-CoV-2 transmission in a day care centre
Kulmala, I. K., Taipale, A., Sanmark, E., Lastovets, N., Sormunen, P., Nuorti, P., Saari, S. E., Luoto, A., & Säämänen, A. J. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e30724 · Cited by 6
Developing and testing low-cost air cleaners for safer spaces during wildfires
Stinson, B. W., & Gall, E. T. (2024) · Science and Technology for the Built Environment · doi:10.1080/23744731.2024.2378675 · Cited by 7
“…given as a range of realistic wildfire PM 2.5 levels), typical residential conditions were assumed: an air exchange rate of 0.5 h − 1 (Murray and Burmaster 1995), a PM 2.5 penetration factor of 0.7 (Long et al. 2001), and an indoor PM 2.5 deposition loss rate of 0.4 h − 1 (Thatcher et al. 2002).”
InfluentialCharacterization of the indoor far-field aerosol transmission in a model commercial office building
Chien, C.-H., Cheng, M., Im, P., Nawaz, K., Fricke, B. A., & Armstrong, A. (2021) · International Communications in Heat and Mass Transfer · doi:10.1016/j.icheatmasstransfer.2021.105744 · Cited by 7
Size distribution, emission rate, and decay characteristics of particles emitted by printers
Zou, C., Jiang, M., Huang, H., Chen, H., Li, S., Li, J., & Yu, C. (2022) · Air Quality Atmosphere & Health · doi:10.1007/s11869-022-01174-3 · Cited by 5
Pallarès, J., & Fabregat, A. (2023) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2023.108685 · Cited by 4
Hoque, S., Farouk, B., & Haas, C. N. (2011) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2011.599266 · Cited by 8
Pallarès, J., & Fabregat, A. (2020) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2020.120691 · Cited by 5
The effect of the ventilation rate on exposure to SARS-CoV-2 in a room with mixing ventilation
Foat, T. G., Higgins, B., Abbs, S., Maishman, T., Gray, L., Kelsey, A., Coldrick, S., Edwards, A. J., Ivings, M. J., Parker, S. T., et al. (2025) · Indoor Environments · doi:10.1016/j.indenv.2025.100129 · Cited by 5
Metadata
- Authors
- Thatcher, T. L., Lai, A. C. K., Moreno-Jackson, R., Sextro, R. G., & Nazaroff, W. W.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Thatcher, Tracy L.
- Venue
- Atmospheric Environment
- Publisher
- Elsevier BV
- Published
- 2002-04
- Volume
- 36
- Issue
- 11
- Pages
- 1811-1819
- ISSN
- 1352-2310 (ISSN-L)
- OpenAlex
- W1540159194
- Semantic Scholar
- c2bc4427f081f059eed6ccb7221bb690707c2e47
- Cited by
- 416
- References
- 18
- Citations by year
- 2026: 18 · 2025: 16 · 2024: 17 · 2023: 25 · 2022: 31 · 2021: 47 · 2020: 20 · 2019: 16 · 2018: 15 · 2017: 9 · 2016: 15 · 2015: 23 · 2014: 16 · 2013: 17 · 2012: 15
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- green
- www.osti.gov
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Atmospheric Environment (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- University of North Texas Digital Library (University of North Texas) (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Lawrence Berkeley National Laboratory
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- particle deposition, indoor air quality, room furnishing, carpets, air velocity, particle size effects, PM2.5, PM10
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.