Effects of room furnishings and air speed on particle deposition rates indoors
Open accessThe DOI matches its Crossref record; 17 of the 18 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“There seems little doubt, when taking into account macro air movements related to heating and ventilation, convection, people activity, and even more localised radiative warming due to equipment, the human body and sunshine through windows, a large fraction of respiratory generated particles will be entrained and suspended in air currents and may potentially travel significant distances over time”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [34]
Citations
Cites
An association between air pollution and mortality in six U.S. cities
Dockery, D. W., Pope, C. A., Xu, X., Spengler, J. D., Ware, J. H., Fay, M. E., Ferris, B. G., & Speizer, F. E. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312093292401 · Cited by 8,018
Deposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859
Self-citationMODELING INDOOR PARTICLE DEPOSITION FROM TURBULENT FLOW ONTO SMOOTH SURFACES
K. Lai, A. C., & Nazaroff, W. W. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00536-4 · Cited by 696
Self-citationHealth effects of particulate air pollution: time for reassessment?
Pope, C. A., Bates, D. V., & Raizenne, M. E. (1995) · Environmental Health Perspectives · doi:10.1289/ehp.95103472 · Cited by 528
Long, C. M., Suh, H. H., Catalano, P. J., & Koutrakis, P. (2001) · Environmental Science & Technology · doi:10.1021/es001477d · Cited by 443
Indoor particulate matter of outdoor origin: Importance of size-dependent removal mechanisms
Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es010723y · Cited by 417
Self-citationActivity patterns of Californians: Use of and proximity to indoor pollutant sources
Jenkins, P. L., Phillips, T. J., Mulberg, E. J., & Hui, S. P. (1992) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(92)90402-7 · Cited by 415
Relative contribution of outdoor and indoor particle sources to indoor concentrations
Abt, E., Suh, H. H., Catalano, P., & Koutrakis, P. (2000) · Environmental Science & Technology · doi:10.1021/es990348y · Cited by 411
Vette, A. F., Rea, A. W., Lawless, P. A., Rodes, C. E., Evans, G., Highsmith, V. R., & Sheldon, L. (2001) · Aerosol Science and Technology · doi:10.1080/02786820117903 · Cited by 186
Penetration of Ambient Fine Particles into the Indoor Environment
Mosley, R. B., Greenwell, D. J., Sparks, L. E., Guo, Z., Tucker, W. G., Fortmann, R., & Whitfield, C. (2001) · Aerosol Science and Technology · doi:10.1080/02786820117449 · Cited by 174
Research works printed but not linked: 1
- Thorshauge, 1982, Air velocity fluctuations in the occupied zone of ventilated spaces, ASHRAE Transactions, 88, 753
Cited by
Items 301–400 of 415
Holistic assessment of advanced technology for ultrafine particle filtration in car cabins
Lesage, M., Chalet, D., Migaud, J., & Krautner, C. (2024) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2024.106439 · Cited by 4
Han, R., Yu, C., Tang, X., Yu, S., Song, M. H., Shen, F., Fu, P., Hu, W., Du, L., Wang, X., et al. (2021) · Environmental Pollution · doi:10.1016/j.envpol.2021.117338 · Cited by 7
Respiratory Virus Deposition and Resuspension from Indoor Surfaces
Rawat, M. S., & Ferro, A. R. (2022) · Springer eBooks · doi:10.1007/978-981-19-1356-3_7 · Cited by 6
Experimental studies of particle removal and probability of COVID-19 infection in passenger railcars
Das, D., Babik, K. R., Moynihan, E. E., & Ramachandran, G. (2022) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2022.2137298 · Cited by 4
“Values between 0.1 and 10 hr 1 have been reported in the literature depending on airspeed and particle size distribution (Thatcher et al. 2002).”
BackgroundInfluentialStinson, B. W., Deters, A. L., & Gall, E. T. (2024) · Indoor Environments · doi:10.1016/j.indenv.2024.100023 · Cited by 6
Zhao, J., Salthammer, T., Schieweck, A., Uhde, E., & Hussein, T. (2025) · Environmental Science Processes & Impacts · doi:10.1039/d4em00663a · Cited by 7
Bai, F., Ding, H. S., Mu, Y., Dai, Y., Zhang, Y., & Tao, W. (2021) · Indoor Air · doi:10.1111/ina.12849 · Cited by 4
Ventilative Cooling and Air Pollutants
da Graça, G. C., & Martins, N. R. (2021) · PoliTO Springer series · doi:10.1007/978-3-030-72385-9_5 · Cited by 5
Characterization of the indoor near-field aerosol transmission in a model commercial office building
Chien, C.-H., Cheng, M., Im, P., Nawaz, K., Fricke, B. A., & Armstrong, A. (2021) · International Communications in Heat and Mass Transfer · doi:10.1016/j.icheatmasstransfer.2021.105745 · Cited by 6
“7 h 1 due to higher micron particle deposition rate of 1 h 1 [20] in Campaigns G and H.”
Yüce, B. E. (2023) · Bitlis Eren Üniversitesi Fen Bilimleri Dergisi · doi:10.17798/bitlisfen.1222870 · Cited by 4
SUDOQU, a new dose-assessment methodology for radiological surface contamination
van Dillen, T., & van Dijk, A. (2018) · Journal of Radiological Protection · doi:10.1088/1361-6498/aacc0a · Cited by 4
Evaluating Human Exposure to Fine Particulate Matter Part I: Measurements
Millar, G., Abel, T., Allen, J. M., Barn, P. K., Noullett, M., Spagnol, J., & Jackson, P. L. (2010) · Geography Compass · doi:10.1111/j.1749-8198.2010.00325.x · Cited by 6
Environmental Health in Built Environments
Nasir, Z. A. (2013) · Wiley eBooks · doi:10.1002/9781118682555.ch14 · Cited by 3
Wallace, L. A., & Smith, K. R. (2006) · CRC Press eBooks · doi:10.1201/9781420012637.ch8 · Cited by 4
Moisture and fungal spore transport in outdoor air-ventilated crawl spaces in a cold climate
Airaksinen, M. (2003) · Aaltodoc (Aalto University) · Cited by 4
Hoque, S., Haas, C. N., & Farouk, B. (2010) · doi:10.17918/etd-3315 · Cited by 4
A Study Towards the Standardisation of Parameters for Testing of Air Purifiers
Kumar, B., Patel, P., & Aggarwal, S. G. (2025) · Aerosol and Air Quality Research · doi:10.1007/s44408-025-00060-8 · Cited by 3
“6 in Thatcher et al. 2002) reaching up to 10 h −1 for 10 µm size.”
InfluentialGoftari, E., Carias, J. R., Fulford, L., & Li, H. (2025) · ACS ES&T Air · doi:10.1021/acsestair.5c00281 · Cited by 5
Wagner, D. N., Jung, N., & Boor, B. E. (2024) · ACS ES&T Air · doi:10.1021/acsestair.4c00140 · Cited by 4
Resuspension of surface particles from the free-fall package: A chamber study
Xu, K., Feng, Y., Wu, J., Fan, Y., & Ge, J. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.112549 · Cited by 4
Surface-deposition and Distribution of the Radon (222Rn and 220Rn) Decay Products Indoors
Espinosa, G., & Tommasino, L. (2015) · Physics Procedia · doi:10.1016/j.phpro.2015.11.103 · Cited by 3
Kylafis, G. F., Tomlin, A. S., Sleigh, A., & Vignes, A. (2018) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2018.12.008 · Cited by 3
Spray Characterization of Aerosol Delivery Systems for Use in Stored Product Facilities
Asuncion, F. X. B., Brabec, D., Casada, M. E., Maghirang, R. G., Arthur, F. H., Campbell, J. F., Zhu, K. Y., & Martin, D. E. (2020) · Transactions of the ASABE · doi:10.13031/trans.14010 · Cited by 3
Almeida, S. M., & Sousa, J. (2021) · Acta Médica Portuguesa · doi:10.20344/amp.15982 · Cited by 4
“Deposição nas superfícies (h-1)(29,39) 0,24 0,24 0,24 0,24 0,24”
Xie, H., Jia, H., Ji, J., Yu, Q., Meng, H., Li, J., & Mu, Y. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112341 · Cited by 3
Surface-deposition and distribution of the radon-decay products indoors
Espinosa, G., & Tommasino, L. (2015) · Journal of Environmental Radioactivity · doi:10.1016/j.jenvrad.2015.02.013 · Cited by 3
Hsieh, N., & Liao, C. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.06.045 · Cited by 3
“Besides the gravitational settling, other factors such as equipment and air speed for mixing fan can also influence the aerosol deposition in the experiment space (Thatcher et al., 2002).”
BackgroundProtecting building occupants against the inhalation of outdoor-origin aerosols
Dillon, M. B., Sextro, R. G., & Delp, W. W. (2021) · Atmospheric Environment · doi:10.1016/j.atmosenv.2021.118773 · Cited by 7
Self-citationIndoor exposure to radiation in the case of an outdoorrelease
Price, P. N., USDOE, & Jayaraman, B. (2006) · doi:10.2172/892947 · Cited by 3
“For the range 1 – 10 µm the deposition rates used in the current study are based on the experiments conducted by Thatcher et al. (2002) in a 2.2 m x 2.7 m x 2.4 m room; these fall more or less in the middle of rates reported in the literature.”
BackgroundMethodInfluentialEvidence-based aerosol clearance times in a healthcare environment
Hara, S. A., Rossman, T., Johnson, L., Hogan, C. J., Sánchez, W., Martin, D. P., & Wehde, M. (2021) · Infection Prevention in Practice · doi:10.1016/j.infpip.2021.100170 · Cited by 3
“This is especially true in rooms with increased surface areas due to furniture and equipment, as is the case in operating and procedures rooms [13].”
Modeling Indoor Inorganic Aerosol Concentrations During the ATHLETIC Campaign with IMAGES
Berman, B. C., Cummings, B. E., Guo, H., Campuzano‐Jost, P., Jimenez, J. L., Pagonis, D., Day, D. A., Finewax, Z., Handschy, A. V., Nault, B. A., et al. (2024) · ACS ES&T Air · doi:10.1021/acsestair.4c00060 · Cited by 2
Recommendations on the effectiveness of sheltering as a protective action in the UK
Bedwell, P., Sherwood, J., McNamara, H., Brown, J., Haywood, S. M., & Field, S. (2025) · Journal of Radiological Protection · doi:10.1088/1361-6498/adf1ae · Cited by 2
“This range encompasses the majority of studies considered by Thatcher et al (2002), Howard-Reed et al (2003) and Byrne (2009), given a particle size range of 0.5–1 µ m and assuming at least one of the two further conditions (a moderately furnished dwelling and a relatively low indoor air flow) are…”
InfluentialThakur, A. K., & Patel, S. (2025) · ACS ES&T Air · doi:10.1021/acsestair.5c00190 · Cited by 2
Field measurements of fine and ultrafine particle penetration factors in Chicago residences
Farhoodi, S., Zhao, H., Heidarinejad, M., & Stephens, B. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113700 · Cited by 2
Airborne dominance in COVID-19 transmission on long-haul flights
Tang, J., Yu, H., Wu, Y., Zhang, Q., Wang, Y., & Xiao, S. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.114223 · Cited by 2
Sandle, T. (2022) · European journal of parenteral & pharmaceutical sciences · doi:10.37521/ejpps.27303 · Cited by 2
“The movement of microbial carrying particles will relate to the complexities of air currents and deposition will be influenced by both particle size and air movement (51).”
BackgroundRen, J., Men, L., Cao, X., Liu, Y., & Kong, X. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.112546 · Cited by 2
Zhou, A., Subramanian, P. S. G., El-Naggar, S., Shisler, J. L., Verma, V., & Nguyen, T. H. (2025) · Applied and Environmental Microbiology · doi:10.1128/aem.02319-24 · Cited by 3
“These align well with findings from earlier studies which typically report the smallest deposition coefficient occurring for a particle diameter in the range of 200–500 nm (24, 25).”
Anspaugh, L. R., Mauro, J. C., Briggs, N., Porrovecchio, J., Amann, W., Salame-Alfie, A., & Ansari, A. J. (2023) · Health Physics · doi:10.1097/hp.0000000000001720 · Cited by 2
Tran, D.-T. (2011) · theses.fr (ABES) · doi:10.70675/1eba9a68z9d6cz402bz83d8zed1798776eeb · Cited by 3
Rush, D. J., Tang, M., & Novoselac, A. (2025) · Science and Technology for the Built Environment · doi:10.1080/23744731.2025.2452141 · Cited by 1
“Thatcher et al. (2002) found that increasing surface area by adding fur-niture to a room increased deposition more for the smallest particles, but that air mixing had a greater effect in increasing removal rates for larger particles.”
Chen, C., Hsu, C.-Y., Ramachandran, G., Khajonklin, T., Yoon, C., & Tsai, P. (2025) · Aerosol and Air Quality Research · doi:10.1007/s44408-025-00028-8 · Cited by 1
“Thatcher et al. (2002) reported deposition loss rate coefficients (λ) in an unoccupied small experimental room, finding values ranging from 0.1 to 0.78 h −1 for particles with diameters between 0.55–2.37 µm.”
InfluentialUm, C. Y., Preble, C. V., Zhao, H., Delp, W. W., Kirchstetter, T. W., Li, J., Schiavon, S., & Singer, B. C. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.114333 · Cited by 1
Measurements and Modeling of GUV222-Driven Increases in SOA Concentrations in an Unoccupied Office
Rutherford, M., Peng, Z., Jenks, O. J., Mesburis, R., Day, D. A., Handschy, A. V., Stark, H. J., Jimenez, J. L., & de Gouw, J. A. (2026) · ACS ES&T Air · doi:10.1021/acsestair.5c00475 · Cited by 2
Mendell, A. Y., Lee, S., & Siegel, J. A. (2026) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-026-00894-3 · Cited by 2
“Most participants reported living by themselves ( N = 52) and usually remaining home throughout the day ( N = 49).”
Spatial variability of indoor particle dynamics induced by the human thermal plume
Cernei, A., Năstase, I., Georgescu, M.-R., Fagniez, T., Thévenet, F., & Verrièle, M. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.115058 · Cited by 1
Chapter 3 Airborne Contamination Inside Dwellings
Byrne, M. A. (2009) · Radioactivity in the environment · doi:10.1016/s1569-4860(09)00403-3 · Cited by 1
Simulation research of the Concentration Distribution of indoor inhaled particulate matters
Liu, H., Zhou, X., & Sun, H. (2013) · International Journal of Online and Biomedical Engineering (iJOE) · doi:10.3991/ijoe.v9is2.2560 · Cited by 1
“Indoor air pollution can be considered as some substances into room caused by human activities or natural processes, which can damage human health because of its sufficient concentration and sustained enough time([1]).”
BackgroundAerosol chemistry and physics: Indoor perspective
Sextro, R. G., & Gundel, L. A. (2004) · CRC Press eBooks · doi:10.1201/9780203493182.ch10 · Cited by 1
Self-citationAn experimental protocol for measuring aerosol deposition in industrial-sized ventilation ducts
Costa, D., Malet, J., & Géhin, É. (2022) · Measurement Science and Technology · doi:10.1088/1361-6501/ac68d3 · Cited by 1
“• a substrate is fixed on the surface of the duct, such as a filter (see [15], for example).”
Fast Method to Design Air Filtration Solution at Low Energy Cost in Subterranean Train Stations
Pretot, P.-E., Schulz, C., Chalet, D., Migaud, J., & Bogdan, M. (2022) · Proceedings of the World Congress on Civil, Structural, and Environmental Engineering · doi:10.11159/iceptp22.167 · Cited by 1
Assessing Mitigation Strategies to Reduce Potential Exposures to Indoor Particle Release Events
Valkinburgh, K. V., Nafchi, A. M., Mousavi, E. S., Blouin, V. Y., Kaye, N. B., & Metcalf, A. R. (2022) · Aerosol and Air Quality Research · doi:10.4209/aaqr.220054 · Cited by 2
“…2022; Ratajczak, 2022; Zhao and Wu, 2009), forced-air stirring vs. calm, unstirred rooms (Schnell et al., 2006), furnishings (Abadie et al., 2001; Thatcher et al., 2002; Thatcher and Nazaroff, 1997), room or building geometry, intrusion of outside air to the indoors (Bi et al., 2021; Han et al.,…”
Air Quality in Latin American Buildings
Molina, C., Jones, B., & Morantes, G. (2023) · Green energy and technology · doi:10.1007/978-3-031-24208-3_14 · Cited by 1
Hussein, T., & Kulmala, M. (2010) · Environmental pollution · doi:10.1007/978-90-481-8663-1_8 · Cited by 1
“Hussein et al. 2009b; Zhao and Wu 2006b; Lai and Nazaroff 2000; Lai et al. 2001, 2002; Thatcher et al. 2002; Abadie et al. 2001; Fogh et al. 1997; Guha 1997).”
BackgroundProgress on building a predictive model of indoor concentrations of outdoor PM-2.5 in homes
Lunden, M. M., USDOE Assistant Secretary for Fossil Energy, W., Thatcher, T. L., Littlejohn, D., Fischer, M., Kirchstetter, T. W., Brown, N., & Hering, S. V. (2001) · doi:10.2172/789176 · Cited by 1
“Many researchers have performed experiments to study particle deposition in the indoor environment (Offermann et al, 1985; Xu et al., 1994; Byrne et. al., 1995; Thatcher and Layton, 1995; Fogh et al., 1997; Vette et al., 2001; Mosley et al., 2001, and Thatcher, et al., 2001 ).”
BackgroundSelf-citationRadioisotope Deposition on Interior Building Surfaces: Air Flow and Surface Roughness Influences
Leonard, B. E. (2005) · Nuclear Technology · doi:10.13182/nt05-a3681 · Cited by 1
Conceição, S. T. (2012) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.3.2012.tde-13062013-164203 · Cited by 9
Celline, P. R. (2017) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.3.2017.tde-11072017-132626 · Cited by 2
Malejan, C. J. (2009) · doi:10.15368/theses.2009.176
“In another study to determine the effects of room furnishings on deposition rates, values between 0.1 to 0.23 hr-1 were found for particle sizes less than 0.55 !m (Thatcher et al., 2002).”
BackgroundInfluentialMeasuring Aerosol Particle Behaviour due to Human Activity Indoors for Re-Exposure Evaluation
McDonagh, A. (2013) · Arrow@dit (Dublin Institute of Technology) · doi:10.13025/17958
Sattari, A. (2015) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
Indoor aerosol transport and deposition for various types of space heating
Podoliak, P., Katolický, J., & Jícha, M. (2009) · WIT transactions on ecology and the environment · doi:10.2495/air090261
“In [7] it is shown the deposition loss rate coefficient as the function of particle size and the velocity of the air.”
BackgroundInfiltration of supermicron aerosols into a simulated space telescope
Liu, D.-L., & Luey, K. T. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.861130
Laußmann, D., & Eis, D. (2009) · Robert-Koch-Institut (RKI) · doi:10.25646/522
“…Untersuchungsräume, der Luftwechsel, die Gesamtoberfläche von Möbeln, das Ober-flächen/Volumenverhältnis der Untersuchungsräume, Tem-peraturdifferenzen zwischen Raumluft und Raumumschlie-ßungsflächen sowie die Oberflächenrauigkeit der Räume (Lai and Nazaroff 2000, Lai 2002, Thatcher et al. 2002).”
Rim, D. (2009) · Texas ScholarWorks (Texas Digital Library)
Stephens, B. R. (2012) · Texas ScholarWorks (Texas Digital Library)
Preliminary Analysis of Particulate Infiltration into Space System Volumes
Liu, D.-L., & Luey, K. T. (2007) · Defense Technical Information Center (DTIC)
Lee, W. (2015) · Digital Access to Scholarship at Harvard (DASH) (Harvard University)
Review of Literature Related to Residential Ventilation Requirements
Lawrence, E. O., Mcwilliams, J., & Sherman, M. (2013)
Saber, E. M., & Bazargan, M. (2015) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-a-010545918
Numerical and Experimental Study of Contaminant Dispersion in a Ventilated Room
Gustiuc, M., Abadie, M., Liman, K., & Colda, I. (2006) · HAL
Howard-Reed, C., Wallace, L. A., & Emmerich, S. J. (2003) · doi:10.1002/https://dx.doi.org/10.6028/nist.ir.7068
“Thatcher et al. (2002) investigated the effect of room furnishings on”
BackgroundMethodInfluentialSIMPLIFIED MODELS FOR PARTICULATE DISPERSION IN BUILDINGS
Schwarzenegger, A. (2008)
Building a predictive model of indoor concentrations of outdoor PM-2.5 in homes
Lunden, M. M., Thatcher, T. L., Littlejohn, D., Fischer, M. L., Kirchstetter, T. W., Brown, N. J., Hering, S. V., & Stolzenburg, M. R. (2001) · eScholarship (California Digital Library)
Self-citationEvaluating Human Health Impacts of Products from a Life Cycle Perspective: Method and Case Studies
Tian, S. (2018) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 1
Fate of particles released by a puff–dispersion with different air distributions
Liu, S., & Novoselac, A. (2018) · Healthy, Intelligent and Resilient Buildings and Urban Environments · doi:10.14305/ibpc.2018.ie-5.03
“We measured particle transport in a test chamber where interior surfaces might be different in surface roughness and area from offices in reality (Thatcher et al., 2002).”
BackgroundNăstase, I., Gustiuc, M., Limam, K., Colda, I., & Niculita, L. (2010) · HAL
A novel radon progeny generator and its control performance for characteristic parameters
Sun, C., Xiao, D., He, Z., Shan, J., & Qiu, S. (2021) · Journal of Radioanalytical and Nuclear Chemistry · doi:10.1007/s10967-021-07743-7
“The basic differential equations in room models are similar to the calculations in radon chamber model calculations published in some literatures [25, 26].”
BackgroundResultSimplified Models For Particle Dispersion In Buildings
Linden, P. F., Bolster, D., & Buckley, S. (2007) · eScholarship (California Digital Library)
External doses from plated-out decay products in radon-rich enclosed spaces
Mostacci, D., Moroder, E., & Cucchi, G. (2022) · Radiation effects and defects in solids · doi:10.1080/10420150.2022.2049790
Surviving Mold Indoor Environmental Professional Panel - Consensus for microbial remediation 2020
The CIRS Academy et.al. (2021) · Medical Research Archives · doi:10.18103/mra.v9i1.2327
Computational Modeling of Aerosol Transmission of COVID-19
Ahmadi, G. (2022) · Springer eBooks · doi:10.1007/978-981-19-1356-3_6
Bao, C. H., Dat, L. T., Khoa, N. Đ., Quang, H. M., Chieu, T. H., & Phuong, N. L. (2022) · Proceedings of International Exchange and Innovation Conference on Engineering & Sciences (IEICES) · doi:10.5109/5909101
Yamamoto, N. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-824411-1.00001-6
Developing and Testing Low-Cost Air Cleaners for Safer Spaces During Wildfires
Stinson, B. W. (2023) · PDXScholar (Portland State University) · doi:10.15760/etd.3588
Wang, Y., Yang, L., Hong, Q., Song, H., Zhang, S., Yang, K., & Fu, X. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4522817 · Cited by 1
Study the behavior of Eulerian and Lagrangian approach in flow dynamics
Sharma, L., Sharma, R., & Taak, N. (2023) · AIP conference proceedings · doi:10.1063/5.0122611
Çetin, H. M. (2023) · Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi · doi:10.17341/gazimmfd.1252002
Çetin, H. M., Özgünler, M., & Arpacıoğlu, Ü. (2024) · Mimarlık Bilimleri ve Uygulamaları Dergisi (MBUD) · doi:10.30785/mbud.1429762
Schumacher, S., & Asbach, C. (2024) · Indoor Environments · doi:10.1016/j.indenv.2024.100054
Effect of Racomitrium canescens on particulate matter reduction under flow and humidity condition
Kim, J. Y., & Kim, J. J. (2025) · Environmental Pollution · doi:10.1016/j.envpol.2025.125741 · Cited by 1
Airborne SARS-CoV-2 Detection by ddPCR in Adequately Ventilated Hospital Corridors
Truyols-Vives, J., González-López, M., Colom, A., Lopez, A. E., Sala, E., Doménech‐Sánchez, A., Baldoví, H. G., & Mercader, J. (2025) · Toxics · doi:10.3390/toxics13070583
“Likewise, differences in the removal rates of CO 2 and bioaerosols will also influence the relationship between CO 2 and SARS-CoV-2 levels, since despite both rates depending on ventilation, the removal rate of bioaerosols also depends on deposition rate and filter efficiency [48–50].”
Miller, S. L. (2020) · The Conversation · doi:10.64628/aai.vamp5uwrv
Transport and distribution of cooking-emitted particles in a residential environment
Zeng, J., Kagi, N., & Umishio, W. (2025) · Journal of Asian Architecture and Building Engineering · doi:10.1080/13467581.2025.2602300
Indoor air quality and health exposure in an educational campus in Western India
Shrivastava, A., Konwar, D., & Bhattu, D. (2026) · Atmospheric Environment · doi:10.1016/j.atmosenv.2026.121790
Metadata
- Authors
- Thatcher, T. L., Lai, A. C. K., Moreno-Jackson, R., Sextro, R. G., & Nazaroff, W. W.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Thatcher, Tracy L.
- Venue
- Atmospheric Environment
- Publisher
- Elsevier BV
- Published
- 2002-04
- Volume
- 36
- Issue
- 11
- Pages
- 1811-1819
- ISSN
- 1352-2310 (ISSN-L)
- OpenAlex
- W1540159194
- Cited by
- 416
- References
- 18
- Citations by year
- 2026: 18 · 2025: 16 · 2024: 17 · 2023: 25 · 2022: 31 · 2021: 47 · 2020: 20 · 2019: 16 · 2018: 15 · 2017: 9 · 2016: 15 · 2015: 23 · 2014: 16 · 2013: 17 · 2012: 15
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- green
- www.osti.gov
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Atmospheric Environment (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- University of North Texas Digital Library (University of North Texas) (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Lawrence Berkeley National Laboratory
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- particle deposition, indoor air quality, room furnishing, carpets, air velocity, particle size effects, PM2.5, PM10
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.