CoChat

Comparison of three oral appliances for treatment of severe obstructive sleep apnea syndrome

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Abstract

Objective: To compare three different oral appliances: a mandibular advancement device (Snoreguard), a tongue retaining device, and a soft palate lift, for treatment of severe obstructive sleep apnea syndrome (OSAS).Background: Oral appliances are therapeutic options for patients with OSAS.Methods: Eight patients with a mean apnea hypopnea index (AHI) of 72.1 (SD+/-39.9) were studied. Polysomnographic measures during each of the treatment nights were compared to baseline.Results: Eight out of 8 patients completed the mandibular advancement device (MAD) night; 5/8 tolerated the tongue retaining device (TRD); only 2/8 could sleep with the soft palate lift (SPL) in place. Improvement using the MAD reached significance: overall AHI (mean+/-SD) decreased from 72.1+/-39.9 at baseline to 35.5+/-39.4 with the appliance in place (P<0.02). There was a non-significant increase in slow wave sleep (SWS) from 9.6%+/-8.7 to 14.4%+/-10.5 with the MAD in place. In five responders, the mean AHI decreased from 60.0+/-36.6 to 9.0+/-4.8; all were subjectively improved, using the MAD at 1 year follow-up. However, three non-responders had persistence of AHI>40. With the TRD, AHI decreased from 50.3+/-18.9 at baseline to 43.5+/-32.5 (ns). The SPL was not effective with an AHI at baseline of 52.4+/-8.0, and 47.3+/-31.0 with the device in place (ns), and not well tolerated.Conclusions: A mandibular advancement device is an effective treatment alternative in some patients with severe OSAS. In comparison, the tongue retaining device and the soft palate lift do not achieve satisfactory results.

Overview

Integrity signals

Registry

Crossref · 10.1016/s1389-9457(00)00030-7

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 31 references

Research works printed but not linked: 2

  1. Parker, 1999, A prospective study evaluating the effectiveness of a mandibular repositioning appliance (PM positioner) for the treatment of moderate obstructive sleep apnea, Sleep, S230
  2. Schoenhofer, 1997, Value of intra- and extraoral devices in the treatment of obstructive sleep apnea and snoring, Medizinische Klinik, 92, 167

Cited by

See all 80

Metadata

Authors
Barthlen, G. M., Brown, L. K., Wiland, M. R., Sadeh, J. S., Patwari, J., & Zimmerman, M.
Affiliations
Icahn School of Medicine at Mount Sinai (US)
Corresponding author
Barthlen, Gabriele M
Venue
Sleep Medicine
Publisher
Elsevier BV
Published
2000-10
Volume
1
Issue
4
Pages
299-305
ISSN
1389-9457 (ISSN-L)
OpenAlex
W2135339542
Cited by
80
References
31
Citations by year
2025: 1 · 2024: 3 · 2023: 2 · 2022: 2 · 2021: 2 · 2020: 2 · 2019: 2 · 2018: 4 · 2017: 4 · 2016: 5 · 2015: 4 · 2014: 5 · 2013: 3 · 2012: 4
FWCI
1.83
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Sleep Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
obstructive sleep apnea, oral appliances, mandibular advancement device, apnea-hypopnea index, polysomnography, slow-wave sleep, treatment tolerance, non-responders

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of three oral appliances for treatment of severe obstructive sleep apnea syndrome. https://app.cochat.ai/papers/10.1016/s1389-9457(00)00030-7
The paper
Barthlen, G. M., Brown, L. K., Wiland, M. R., Sadeh, J. S., Patwari, J., & Zimmerman, M. (2000). Comparison of three oral appliances for treatment of severe obstructive sleep apnea syndrome. Sleep Medicine. https://doi.org/10.1016/s1389-9457(00)00030-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.