CoChat

Therapeutic drug monitoring when using cefepime in continuous renal replacement therapy: seizures associated with cefepime

Open access
Smith, Nicholas L, Freebairn, Ross C, Park, Michael A J, Wallis, Steven C, Roberts, Jason A, Lipman, Jeffrey · 2012 · Critical Care and Resuscitation
Cited by 41

The DOI matches its Crossref record.

Abstract

Ensuring effective, safe drug dosing in critically ill patients can be difficult, due to variable and dynamic organ function. An 82-year-old man was admitted to the intensive care unit with severe community-acquired pneumonia, septic shock and progressive organ failure. He required ventilation and continuous renal replacement therapy. He developed seizures which we believe were due to cefepime toxicity. Following the first seizure, we took serial measurements of plasma cefepime levels, and a single measurement of the cerebrospinal fluid (CSF) cefepime level. The peak plasma cefepime concentration was 73.8 µg/mL (minimum inhibitory concentration of target enterobacteriaceae is 8 µg/mL) and the CSF level was 6.1 µg/mL. The patient had four seizures during the period of high plasma cefepime concentration, but no more episodes once the drug level decreased to non-toxic levels. This case highlights the difficulty in predicting pharmacokinetics in critically ill patients, particularly those receiving renal replacement therapy. We suggest that therapeutic drug monitoring in critically ill patients may be a useful intervention to avoid antibiotic-related toxicities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s1441-2772(23)01773-8

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 41

Metadata

Authors
Smith, N. L., Freebairn, R. C., Park, M. A. J., Wallis, S. C., Roberts, J. A., & Lipman, J.
Venue
Critical Care and Resuscitation
Publisher
Elsevier BV
Published
2012-12
Volume
14
Issue
4
Pages
312-315
ISSN
1441-2772 (ISSN-L)
OpenAlex
W85087597
Cited by
41
References
0
FWCI
2.68
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Therapeutic drug monitoring when using cefepime in continuous renal replacement therapy: seizures associated with cefepime. https://app.cochat.ai/papers/10.1016/s1441-2772(23)01773-8
The paper
Smith, N. L., Freebairn, R. C., Park, M. A. J., Wallis, S. C., Roberts, J. A., & Lipman, J. (2012). Therapeutic drug monitoring when using cefepime in continuous renal replacement therapy: seizures associated with cefepime. Critical Care and Resuscitation. https://doi.org/10.1016/s1441-2772(23)01773-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.