Rapid and Sensitive Strategy for Salmonella Detection Using an InvA Gene-Based Electrochemical DNA Sensor
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
A rapid and sensitive strategy for the detection of Salmonella was proposed by integrating simple DNA extraction, specific polymerase chain reaction (PCR) with an invA gene-based electrochemical DNA sensor. The amplified target sequence of invA gene could be specifically captured on the sensing interface, and further hybridized with biotinylated detection probe to form a sandwich-type hybridization structure. The electrochemical signal was amplified by streptavidin-alkaline phosphatase (ST-AP), producing sensitive enzyme-catalyzed electrochemical DNA sensing. The fabrication and hybridization processes were characterized with electrochemical impedance spectroscopy (EIS), square wave voltammetry (SWV) and surface plasmon resonance (SPR). The designed DNA sensor could discriminate satisfactorily the complementary and mismatched oligonucleotides, indicating good selectivity. The linear calibration range for target DNA detection was from 1 pM to 10 nM with a detection limit of 0.5 pM, showing high sensitivity. Under optimal conditions, the proposed strategy could quantitatively detect Salmonella from 10 to 105 CFU mL-1 within 3.5 h. This strategy presented a simple, rapid and sensitive platform for Salmonella detection and would become a powerful tool for pathogenic microorganisms screening in clinical diagnostics, food safety, biothreat detection and environmental monitoring.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The virulence of Salmonella is linked to a combination of chromosomal and plasmid factors; the invA gene serves also as a specific biomarker for the identification of the genus Salmonella [12].”
From Characterization of virulence factors of Salmonella isolated from human stools and street food in urban areas of Burkina Faso (2021) · cites this paper as [12]
Citations
Cites
Real-Time PCR for mRNA Quantitation
Wong, M. L., & Medrano, J. F. (2005) · BioTechniques · doi:10.2144/05391rv01 · Cited by 1,786
Rahn, K., De Grandis, S. A., Clarke, R. C., McEwen, S. A., Galán, J. E., Ginocchio, C., Curtiss, R., & Gyles, C. L. (1992) · Molecular and Cellular Probes · doi:10.1016/0890-8508(92)90002-f · Cited by 1,065
Hendriksen, R. S., Vieira, A. R., Karlsmose, S., Lo Fo Wong, D. M. A., Jensen, A. B., Wegener, H. C., & Aarestrup, F. M. (2011) · Foodborne Pathogens and Disease · doi:10.1089/fpd.2010.0787 · Cited by 633
Malorny, B., Hoorfar, J., Bunge, C., & Helmuth, R. (2003) · Applied and Environmental Microbiology · doi:10.1128/aem.69.1.290-296.2003 · Cited by 549
Fast detection of Salmonella Infantis with carbon nanotube field effect transistors
Villamizar, R. A., Maroto, A., Rius, F. X., Inza, I., & Figueras, M. J. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.03.046 · Cited by 184
TIRADO, C., & SCHMIDT, K. (2001) · Journal of Infection · doi:10.1016/s0163-4453(01)90861-8 · Cited by 182
Detection of Salmonella typhimurium using an electrochemical immunosensor
Salam, F., & Tothill, I. E. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.01.025 · Cited by 169
Li, S., Li, Y., Chen, H., Horikawa, S., Shen, W., Simonian, A., & Chin, B. A. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.029 · Cited by 164
Rapid and sensitive biosensor for Salmonella
Pathirana, S., Barbaree, J. M., Chin, B. A., Hartell, M. G., Neely, W. C., & Vodyanoy, V. J. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00067-1 · Cited by 157
Bacteriophage tailspike proteins as molecular probes for sensitive and selective bacterial detection
Singh, A., Arya, S. K., Glass, N. R., Hanifi-Moghaddam, P., Naidoo, R., Szymanski, C. M., Tanha, J., & Evoy, S. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.024 · Cited by 150
Cited by
Electrochemical impedance spectroscopy: an overview of bioanalytical applications
Randviir, E. P., & Banks, C. E. (2013) · Analytical Methods · doi:10.1039/c3ay26476a · Cited by 795
Electrochemical Methodologies for the Detection of Pathogens
Amiri, M., Bezaatpour, A., Jafari, H., Boukherroub, R., & Szunerits, S. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00239 · Cited by 249
Luo, C., Tang, H., Cheng, W., Li, Y., Zhang, D., Ju, H., & Ding, S. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.03.084 · Cited by 148
Self-citationSensitive electrochemical detection of Salmonella with chitosan–gold nanoparticles composite film
Xiang, C., Li, R., Adhikari, B., She, Z., Li, Y., & Kraatz, H. (2015) · Talanta · doi:10.1016/j.talanta.2015.03.033 · Cited by 101
Tabrizi, M. A., & Shamsipur, M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.02.024 · Cited by 93
Metadata
- Authors
- Li, Q., Cheng, W., Zhang, D., Yu, T., Yin, Y., Ju, H., & Ding, S.
- Affiliations
- Chongqing Medical University (CN)
- The Affiliated Yongchuan Hospital of Chongqing Medical University (CN)
- State Key Laboratory of Analytical Chemistry for Life Science (CN)
- Corresponding author
- Ding, Shijia
- Venue
- International Journal of Electrochemical Science
- Publisher
- Elsevier BV
- Published
- 2012-01
- Volume
- 7
- Issue
- 1
- Pages
- 844-856
- ISSN
- 1452-3981 (ISSN-L)
- OpenAlex
- W4382141130
- Cited by
- 67
- References
- 26
- Citations by year
- 2026: 4 · 2025: 1 · 2024: 3 · 2023: 5 · 2022: 3 · 2021: 4 · 2020: 3 · 2019: 3 · 2018: 6 · 2017: 6 · 2016: 6 · 2015: 9 · 2014: 6 · 2013: 6 · 2012: 2
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc-nd
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor, 4194 d)
- Locations
- International Journal of Electrochemical Science (publishedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- National Natural Science Foundation of China (2107514)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Keywords
- Salmonella detection, electrochemical DNA biosensor, invA gene, sandwich hybridization, streptavidin-alkaline phosphatase, food safety, pathogen screening
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid and Sensitive Strategy for Salmonella Detection Using an InvA Gene-Based Electrochemical DNA Sensor. https://app.cochat.ai/papers/10.1016/s1452-3981(23)13380-3
- The paper
- Li, Q., Cheng, W., Zhang, D., Yu, T., Yin, Y., Ju, H., & Ding, S. (2012). Rapid and Sensitive Strategy for Salmonella Detection Using an InvA Gene-Based Electrochemical DNA Sensor. International Journal of Electrochemical Science. https://doi.org/10.1016/s1452-3981(23)13380-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.