Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 549

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Multicenter Validation of the Analytical Accuracy of Salmonella PCR: towards an International Standard

Open access
Malorny, Burkhard, Hoorfar, Jeffrey, Bunge, Cornelia, Helmuth, Reiner·2003·Applied and Environmental Microbiology

Abstract

As part of a major international project for the validation and standardization of PCR for detection of five major food-borne pathogens, four primer sets specific for Salmonella species were evaluated in-house for their analytical accuracy (selectivity and detection limit) in identifying 43 Salmonella spp. and 47 non-Salmonella strains. The most selective primer set was found to be 139-141 (K. Rahn, S. A. De Grandis, R. C. Clarke, S. A. McEwen, J. E. Galán, C. Ginocchio, R. Curtiss III, and C. L. Gyles, Mol. Cell. Probes 6:271-279, 1992), which targets the invA gene. An extended determination of selectivity by using 364 strains showed that the inclusivity was 99.6% and the exclusivity was 100% for the invA primer set. To indicate possible PCR inhibitors derived from the sample DNA, an internal amplification control (IAC), which was coamplified with the invA target gene, was constructed. In the presence of 300 DNA copies of the IAC, the detection probability for primer set 139-141 was found to be 100% when a cell suspension containing 10 4 CFU/ml was used as the template in the PCR (50 CFU per reaction). The primer set was further validated in an international collaborative study that included 16 participating laboratories. Analysis with 28 coded (“blind”) DNA samples revealed an analytical accuracy of 98%. Thus, a simple PCR assay that is specific for Salmonella spp. and amplifies a chromosomal DNA fragment detected by gel electrophoresis was established through extensive validation and is proposed as an international standard. This study addresses the increasing demand of quality assurance laboratories for standard diagnostic methods and presents findings that can facilitate the international comparison and exchange of epidemiological data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/aem.69.1.290-296.2003

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 549

Metadata

Authors
Malorny, B., Hoorfar, J., Bunge, C., & Helmuth, R.
Venue
Applied and Environmental Microbiology
Published
2003-01
Volume
69
Issue
1
Pages
290-296
ISSN
  • 0099-2240 (ISSN-L)
  • 1098-5336
OpenAlex
W1966615916
Cited by
549
References
13
FWCI
36.32
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multicenter Validation of the Analytical Accuracy of Salmonella PCR: towards an International Standard. https://app.cochat.ai/papers/10.1128/aem.69.1.290-296.2003
The paper
Malorny, B., Hoorfar, J., Bunge, C., & Helmuth, R. (2003). Multicenter Validation of the Analytical Accuracy of Salmonella PCR: towards an International Standard. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.69.1.290-296.2003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.