Multiple-source current steering in subthalamic nucleus deep brain stimulation for Parkinson's disease (the VANTAGE study): a non-randomised, prospective, multicentre, open-label study
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
BACKGROUND High-frequency deep brain stimulation (DBS) with a single electrical source is effective for motor symptom relief in patients with Parkinson's disease. We postulated that a multiple-source, constant-current device that permits well defined distribution of current would lead to motor improvement in patients with Parkinson's disease. METHODS We did a prospective, multicentre, non-randomised, open-label intervention study of an implantable DBS device (the VANTAGE study) at six specialist DBS centres at universities in six European countries. Patients were judged eligible if they were aged 21-75 years, had been diagnosed with bilateral idiopathic Parkinson's disease with motor symptoms for more than 5 years, had a Hoehn and Yahr score of 2 or greater, and had a Unified Parkinson's disease rating scale part III (UPDRS III) score in the medication-off state of more than 30, which improved by 33% or more after a levodopa challenge. Participants underwent bilateral implantation in the subthalamic nucleus of a multiple-source, constant-current, eight-contact, rechargeable DBS system, and were assessed 12, 26, and 52 weeks after implantation. The primary endpoint was the mean change in UPDRS III scores (assessed by site investigators who were aware of the treatment assignment) from baseline (medication-off state) to 26 weeks after first lead implantation (stimulation-on, medication-off state). This study is registered with ClinicalTrials.gov, number NCT01221948. FINDINGS Of 53 patients enrolled in the study, 40 received a bilateral implant in the subthalamic nucleus and their data contributed to the primary endpoint analysis. Improvement was noted in the UPDRS III motor score 6 months after first lead implantation (mean 13·5 [SD 6·8], 95% CI 11·3-15·7) compared with baseline (37·4 [8·9], 34·5-40·2), with a mean difference of 23·8 (SD 10·6; 95% CI 20·3-27·3; p<0·0001). One patient died of pneumonia 24 weeks after implantation, which was judged to be unrelated to the procedure. 125 adverse events were reported, the most frequent of which were dystonia, speech disorder, and apathy. 18 serious adverse events were recorded, three of which were attributed to the device or procedure (one case each of infection, migration, and respiratory depression). All serious adverse events resolved without residual effects and stimulation remained on during the study. INTERPRETATION The multiple-source, constant-current, eight-contact DBS system suppressed motor symptoms effectively in patients with Parkinson's disease, with an acceptable safety profile. Future trials are needed to investigate systematically the potential benefits of this system on postoperative outcome and its side-effects. FUNDING Boston Scientific.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Systematic review of levodopa dose equivalency reporting in Parkinson's disease
Tomlinson, C. L., Stowe, R., Patel, S., Rick, C., Gray, R., & Clarke, C. E. (2010) · Movement Disorders · doi:10.1002/mds.23429 · Cited by 4,219
A Randomized Trial of Deep-Brain Stimulation for Parkinson's Disease
Deuschl, G., Schade-Brittinger, C., Krack, P., Volkmann, J., Schäfer, H., Bötzel, K., Daniels, C., Deutschländer, A., Dillmann, U., Eisner, W., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa060281 · Cited by 2,944
Self-citationWeaver, F. M. (2009) · JAMA · doi:10.1001/jama.2008.929 · Cited by 1,525
Neurostimulation for Parkinson's Disease with Early Motor Complications
Schuepbach, W. M. M., Rau, J., Knudsen, K., Volkmann, J., Krack, P., Timmermann, L., Hälbig, T. D., Hesekamp, H., Navarro, S. M., Meier, N., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1205158 · Cited by 1,430
Self-citationEffect on parkinsonian signs and symptoms of bilateral subthalamic nucleus stimulation
Limousin, P., Pollak, P., Benazzouz, A., Hoffmann, D., Le Bas, J.-F., Perret, J. E., Benabid, A.-L., & Broussolle, E. (1995) · The Lancet · doi:10.1016/s0140-6736(95)90062-4 · Cited by 1,392
Pallidal versus Subthalamic Deep-Brain Stimulation for Parkinson's Disease
Follett, K. A., Weaver, F. M., Stern, M., Hur, K., Harris, C. L., Luo, P., Marks, W. J., Rothlind, J., Sagher, O., Moy, C., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0907083 · Cited by 1,355
Core assessment program for intracerebral transplantations (CAPIT)
Langston, J. W., Widner, H., Goetz, C. G., Brooks, D., Fahn, S., Freeman, T., & Watts, R. (1992) · Movement Disorders · doi:10.1002/mds.870070103 · Cited by 1,008
Core assessment program for surgical interventional therapies in Parkinson's disease (CAPSIT-PD)
Defer, G.-L., Widner, H., Mari�, R.-M., R�my, P., Levivier, M., & Conference Participants: Conference Participants: G. L. Defer, M. (. (1999) · Movement Disorders · doi:10.1002/1531-8257(199907)14:4<572::aid-mds1005>3.0.co;2-c · Cited by 865
Williams, A., Gill, S., Varma, T., Jenkinson, C., Quinn, N., Mitchell, R., Scott, R., Ives, N., Rick, C., Daniels, J., et al. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70093-4 · Cited by 733
Self-citationA multicentre study on suicide outcomes following subthalamic stimulation for Parkinson's disease
Voon, V., Krack, P., Lang, A. E., Lozano, A. M., Dujardin, K., Schüpbach, M., D’Ambrosia, J., Thobois, S., Tamma, F., Herzog, J., et al. (2008) · Brain · doi:10.1093/brain/awn214 · Cited by 472
Okun, M. S., Gallo, B. V., Mandybur, G., Jagid, J., Foote, K. D., Revilla, F. J., Alterman, R., Jankovic, J., Simpson, R., Junn, F., et al. (2012) · The Lancet Neurology · doi:10.1016/s1474-4422(11)70308-8 · Cited by 409
Sources and effects of electrode impedance during deep brain stimulation
Butson, C. R., Maks, C. B., & McIntyre, C. C. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.10.007 · Cited by 360
Directional deep brain stimulation: an intraoperative double-blind pilot study
Pollo, C., Kaelin-Lang, A., Oertel, M. F., Stieglitz, L., Taub, E., Fuhr, P., Lozano, A. M., Raabe, A., & Schüpbach, M. (2014) · Brain · doi:10.1093/brain/awu102 · Cited by 327
Multiple Hypotheses Testing with Weights
Benjamini, Y., & Hochberg, Y. (1997) · Scandinavian Journal of Statistics · doi:10.1111/1467-9469.00072 · Cited by 311
Minimal clinically important change on the unified Parkinson's disease rating scale
Schrag, A., Sampaio, C., Counsell, N., & Poewe, W. (2006) · Movement Disorders · doi:10.1002/mds.20914 · Cited by 297
Most effective stimulation site in subthalamic deep brain stimulation for Parkinson's disease
Herzog, J., Fietzek, U., Hamel, W., Morsnowski, A., Steigerwald, F., Schrader, B., Weinert, D., Pfister, G., Müller, D., Mehdorn, H. M., et al. (2004) · Movement Disorders · doi:10.1002/mds.20056 · Cited by 253
Current steering to control the volume of tissue activated during deep brain stimulation
Butson, C. R., & McIntyre, C. C. (2008) · Brain Stimulation · doi:10.1016/j.brs.2007.08.004 · Cited by 236
Gatekeeping strategies for clinical trials that do not require all primary effects to be significant
Dmitrienko, A., Offen, W. W., & Westfall, P. H. (2003) · Statistics in Medicine · doi:10.1002/sim.1526 · Cited by 227
Chaturvedi, A., Foutz, T. J., & McIntyre, C. C. (2011) · Brain stimulation · doi:10.1016/j.brs.2011.05.002 · Cited by 95
The Rationale Driving the Evolution of Deep Brain Stimulation to Constant-Current Devices
Bronstein, J. M., Tagliati, M., McIntyre, C. C., Chen, R. E., Cheung, T., Hargreaves, E. L., Israel, Z. H., Moffitt, M. A., Montgomery, E. B., Stypulkowski, P. H., et al. (2014) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.12227 · Cited by 89
Individualized current-shaping reduces DBS-induced dysarthria in patients with essential tremor
Barbe, M. T., Dembek, T. A., Becker, J., Raethjen, J., Hartinger, M., Meister, I. G., Runge, M. J. R., Maarouf, M., Fink, G. R., & Timmermann, L. (2014) · Neurology · doi:10.1212/wnl.0000000000000127 · Cited by 83
Self-citationLongitudinal Impedance Variability in Patients with Chronically Implanted DBS Devices
Cheung, T., Nuno, M. A., Hoffman, M., Katz, M., Kilbane, C., Alterman, R. L., & Tagliati, M. (2013) · Brain stimulation · doi:10.1016/j.brs.2013.03.010 · Cited by 69
A New Rechargeable Device for Deep Brain Stimulation: A Prospective Patient Satisfaction Survey
Timmermann, L., Schüpbach, M. W. M., Hertel, F., Wolf, E., Eleopra, R., Franzini, A., Servello, D., Skogseid, I. M., Rumià, J., Aliaga, A. S., et al. (2013) · European Neurology · doi:10.1159/000342236 · Cited by 54
Self-citationMyths and facts about the EARLYSTIM study
Schüpbach, M. W. M., Rau, J., Houéto, J., Krack, P., Schnitzler, A., Schade‐Brittinger, C., Timmermann, L., & Deuschl, G. (2014) · Movement Disorders · doi:10.1002/mds.26080 · Cited by 54
Self-citationOpen‐label surgical trials for Parkinson disease: Time for reconsideration
Alterman, R. L., Tagliati, M., & Olanow, C. W. (2011) · Annals of Neurology · doi:10.1002/ana.22453 · Cited by 31
Steering technology for deep brain stimulation
Green, A. L., & Aziz, T. Z. (2014) · Brain · doi:10.1093/brain/awu126 · Cited by 8
Cited by
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
“As a result, most device manufacturers have moved towards constant-current stimulation paradigms where the charge density delivered by the stimulating electrode does not depend on day-to-day changes in impedance of the tissue/electrode interface 58,59 .”
The modulatory effect of adaptive deep brain stimulation on beta bursts in Parkinson’s disease
Tinkhauser, G., Pogosyan, A., Little, S., Beudel, M., Herz, D. M., Tan, H., & Brown, P. (2017) · Brain · doi:10.1093/brain/awx010 · Cited by 454
Emerging technologies for improved deep brain stimulation
Cagnan, H., Denison, T., McIntyre, C., & Brown, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0244-6 · Cited by 272
Steigerwald, F., Müller, L., Johannes, S., Matthies, C., & Volkmann, J. (2016) · Movement Disorders · doi:10.1002/mds.26669 · Cited by 242
“DBS of the STN has proven to be a safe, effective treatment for patients with severe tremor, motor fluctuations, or dyskinesia in Parkinson’s disease.(1,2) However, individual outcomes may vary greatly and critically depend on the brain volume being stimulated.”
BackgroundKoeglsperger, T., Palleis, C., Hell, F., Mehrkens, J. H., & Bötzel, K. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00410 · Cited by 235
Metadata
- Authors
- Timmermann, L., Jain, R., Chen, L., Maarouf, M., Barbe, M. T., Allert, N., Brücke, T., Kaiser, I., Beirer, S., Sejio, F., Suarez, E., Lozano, B., Haegelen, C., Vérin, M., Porta, M., Servello, D., Gill, S., Whone, A., Van Dyck, N., & Alesch, F.
- Venue
- The Lancet Neurology
- Publisher
- Elsevier BV
- Published
- 2015-07
- Volume
- 14
- Issue
- 7
- Pages
- 693-701
- ISSN
- 1474-4422 (ISSN-L)
- OpenAlex
- W2098212057
- Cited by
- 167
- References
- 26
- FWCI
- 11.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.