The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Directional deep brain stimulation: an intraoperative double-blind pilot study
Open accessAbstract
Deep brain stimulation of different targets has been shown to drastically improve symptoms of a variety of neurological conditions. However, the occurrence of disabling side effects may limit the ability to deliver adequate amounts of current necessary to reach the maximal benefit. Computed models have suggested that reduction in electrode size and the ability to provide directional stimulation could increase the efficacy of such therapies. This has never been demonstrated in humans. In the present study, we assess the effect of directional stimulation compared to omnidirectional stimulation. Three different directions of stimulation as well as omnidirectional stimulation were tested intraoperatively in the subthalamic nucleus of 11 patients with Parkinson's disease and in the nucleus ventralis intermedius of two other subjects with essential tremor. At the trajectory chosen for implantation of the definitive electrode, we assessed the current threshold window between positive and side effects, defined as the therapeutic window. A computed finite element model was used to compare the volume of tissue activated when one directional electrode was stimulated, or in case of omnidirectional stimulation. All but one patient showed a benefit of directional stimulation compared to omnidirectional. A best direction of stimulation was observed in all the patients. The therapeutic window in the best direction was wider than the second best direction (P = 0.003) and wider than the third best direction (P = 0.002). Compared to omnidirectional direction, the therapeutic window in the best direction was 41.3% wider (P = 0.037). The current threshold producing meaningful therapeutic effect in the best direction was 0.67 mA (0.3-1.0 mA) and was 43% lower than in omnidirectional stimulation (P = 0.002). No complication as a result of insertion of the directional electrode or during testing was encountered. The computed model revealed a volume of tissue activated of 10.5 mm(3) in omnidirectional mode, compared with 4.2 mm(3) when only one electrode was used. Directional deep brain stimulation with a reduced electrode size applied intraoperatively in the subthalamic nucleus as well as in the nucleus ventralis intermedius of the thalamus significantly widened the therapeutic window and lowered the current needed for beneficial effects, compared to omnidirectional stimulation. The observed side effects related to direction of stimulation were consistent with the anatomical location of surrounding structures. This new approach opens the door to an improved deep brain stimulation therapy. Chronic implantation is further needed to confirm these findings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681
Probing and regulating dysfunctional circuits using deep brain stimulation
Lozano, A. M., & Lipsman, N. (2013) · Neuron · doi:10.1016/j.neuron.2013.01.020 · Cited by 665
Self-citationRapid effects of deep brain stimulation for treatment-resistant major depression
Schlaepfer, T. E., Bewernick, B. H., Kayser, S., Mädler, B., & Coenen, V. A. (2013) · Biological Psychiatry · doi:10.1016/j.biopsych.2013.01.034 · Cited by 563
Cited by
Deep Brain Stimulation: A Paradigm Shifting Approach to Treat Parkinson's Disease
Hickey, P., & Stacy, M. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00173 · Cited by 125
Dayal, V., Limousin, P., & Foltynie, T. (2017) · Journal of Parkinson’s Disease · doi:10.3233/jpd-171077 · Cited by 108
Mind Reading and Writing: The Future of Neurotechnology
Roelfsema, P. R., Denys, D., & Klink, P. C. (2018) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2018.04.001 · Cited by 107
Deep brain stimulation and electromagnetic interference
Rahimpour, S., Kiyani, M., Hodges, S. E., & Turner, D. A. (2021) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2021.106577 · Cited by 63
Shah, A., Coste, J., Lemaire, J.-J., Taub, E., Schüpbach, W. M. M., Pollo, C., Schkommodau, E., Guzman, R., & Hemm-Ode, S. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1559-9 · Cited by 21
Self-citation
Metadata
- Authors
- Pollo, C., Kaelin-Lang, A., Oertel, M. F., Stieglitz, L., Taub, E., Fuhr, P., Lozano, A. M., Raabe, A., & Schüpbach, M.
- Venue
- Brain
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-05-19
- Volume
- 137
- Issue
- 7
- Pages
- 2015-2026
- ISSN
- 0006-8950 (ISSN-L)
- 1460-2156
- OpenAlex
- W2103105094
- Cited by
- 327
- References
- 3
- FWCI
- 18.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Directional deep brain stimulation: an intraoperative double-blind pilot study. https://app.cochat.ai/papers/10.1093/brain/awu102
- The paper
- Pollo, C., Kaelin-Lang, A., Oertel, M. F., Stieglitz, L., Taub, E., Fuhr, P., Lozano, A. M., Raabe, A., & Schüpbach, M. (2014). Directional deep brain stimulation: an intraoperative double-blind pilot study. Brain. https://doi.org/10.1093/brain/awu102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.