CoChat

Using Variance Analysis to Detect Hazards in a Bar-Code–Assisted Medication Preparation Process

Escoto, Kamisha Hamilton, Hallock, Melissa, Wagner, Jennifer, Karsh, Ben-Tzion · 2004 · The Joint Commission Journal on Quality and Safety

The DOI matches its Crossref record; 13 of the 14 references it cites were found in a registry or an index.

Abstract

Background Medication errors have received significant attention, with studies pinpointing problems in the physician ordering, pharmacy dispensing, and nurse administering processes. Yet, the nursing process for preparing medications, which typically occurs in a medication room on the unit, has not received much attention. This process is deceptively complex, and without proper design, it could break down at numerous points.Human factors engineering analysis Prospective hazard analysis methods allow the detection of potential hazards during the planning, assessment, and design phases of a process or technology. A specific technique-variance analysis-is used within one type of prospective hazard analysis, the sociotechnical systems analysis (STSA). STSA provides guidance to (1) analyze existing or planned systems to understand the social, technical, and environmental system components; (2) collect and analyze the system data; and (3) use the analysis to design or redesign the system.Discussion The STSA variance analysis is an additional tool that health care clinicians, administrators, and risk managers can use to proactively identify hazards for control. Although this larger analysis is more time consuming, it forces the analysts to conduct a true systems analysis before implementing technical, social, environmental, or organizational changes.

Overview

Integrity signals

Registry

Crossref · 10.1016/s1549-3741(04)30073-0

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 13 references

Cited by

See all 12

Metadata

Authors
Escoto, K. H., Hallock, M., Wagner, J., & Karsh, B.-T.
Affiliations
University of Wisconsin–Madison (US)
Corresponding author
Karsh, Ben-Tzion
Venue
The Joint Commission Journal on Quality and Safety
Publisher
Elsevier BV
Published
2004-11
Volume
30
Issue
11
Pages
622-628
ISSN
1549-3741 (ISSN-L)
OpenAlex
W2412493385
Cited by
12
References
14
Citations by year
2020: 1 · 2019: 1 · 2015: 1 · 2014: 1 · 2013: 2 · 2012: 1
FWCI
0.91
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • The Joint Commission Journal on Quality and Safety (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
  • Physical Sciences › Engineering › Safety, Risk, Reliability and Quality › Risk and Safety Analysis
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Safe Handling of Antineoplastic Drugs
Keywords
medication errors, drug preparation, barcode medication administration, analysis of variance, nursing process, threat detection, patient safety, human factors engineering
MeSH terms
Analysis of Variance, Electronic Data Processing, Humans, Ergonomics, Medication Errors, Medication Systems, Hospital, Nursing Process, Risk Management, Systems Analysis, Proportional Hazards Models

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Using Variance Analysis to Detect Hazards in a Bar-Code–Assisted Medication Preparation Process. https://app.cochat.ai/papers/10.1016/s1549-3741(04)30073-0
The paper
Escoto, K. H., Hallock, M., Wagner, J., & Karsh, B.-T. (2004). Using Variance Analysis to Detect Hazards in a Bar-Code–Assisted Medication Preparation Process. The Joint Commission Journal on Quality and Safety. https://doi.org/10.1016/s1549-3741(04)30073-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.