Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 396

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Diagnostic accuracy of transbronchial lung cryobiopsy for interstitial lung disease diagnosis (COLDICE): a prospective, comparative study

Troy, Lauren K, Grainge, Christopher, Corte, Tamera J, Williamson, Jonathan P, Vallely, Michael P, Cooper, Wendy A, Mahar, Annabelle, Myers, Jeffrey L, Lai, Simon, Mulyadi, Ellie, Torzillo, Paul J, Phillips, Martin J, Jo, Helen E, Webster, Susanne E, Lin, Qi T, Rhodes, Jessica E, Salamonsen, Matthew, Wrobel, Jeremy P, Harris, Benjamin, Don, Garrick, Wu, Peter J C, Ng, Benjamin J, Oldmeadow, Christopher, Raghu, Ganesh, Lau, Edmund M T, Arnold, David, Cao, Christopher, Cashmore, Amy, Cleary, Shannon, Evans, Tiffany-Jane, French, Bruce, Geis, Monika, Glenn, Laura, Hibbert, Michael, Ing, Alvin, James, Allen, Meredith, Graham, Merry, Christopher, Pudipeddi, Anand, Saghaie, Tajalli, Thomas, Rajesh, Thomson, Claire, Twaddell, Scott · 2020 · The Lancet Respiratory Medicine

Abstract

BACKGROUND Transbronchial lung cryobiopsy (TBLC) is a novel technique for sampling lung tissue for interstitial lung disease diagnosis. The aim of this study was to establish the diagnostic accuracy of TBLC compared with surgical lung biopsy (SLB), in the context of increasing use of TBLC in clinical practice as a less invasive biopsy technique. METHODS COLDICE was a prospective, multicentre, diagnostic accuracy study investigating diagnostic agreement between TBLC and SLB, across nine Australian tertiary hospitals. Patients with interstitial lung disease aged between 18 and 80 years were eligible for inclusion if they required histopathological evaluation to aid diagnosis, after detailed baseline evaluation. After screening at a centralised multidisciplinary discussion (MDD), patients with interstitial lung disease referred for lung biopsy underwent sequential TBLC and SLB under one anaesthetic. Each tissue sample was assigned a number between 1 and 130, allocated in a computer-generated random sequence. Encoded biopsy samples were then analysed by masked pathologists. At subsequent MDD, de-identified cases were discussed twice with either TBLC or SLB along with clinical and radiological data, in random non-consecutive order. Co-primary endpoints were agreement of histopathological features in TBLC and SLB for patterns of definite or probable usual interstitial pneumonia, indeterminate for usual interstitial pneumonia, and alternative diagnosis; and for agreement of consensus clinical diagnosis using TBLC and SLB at MDD. Concordance and κ values were calculated for each primary endpoint. This study is registered with the Australian New Zealand Clinical Trials Registry, ACTRN12615000718549. FINDINGS Between March 15, 2016, and April 15, 2019, we enrolled 65 patients (31 [48%] men, 34 [52%] women; mean age 66·1 years [SD 9·3]; forced vital capacity 83·7% [SD 14·2]; diffusing capacity for carbon monoxide 63·4% [SD 12·8]). TBLC (7·1 mm, SD 1·9) and SLB (46·5 mm, 14·9) samples were each taken from two separate ipsilateral lobes. Histopathological agreement between TBLC and SLB was 70·8% (weighted κ 0·70, 95% CI 0·55-0·86); diagnostic agreement at MDD was 76·9% (κ 0·62, 0·47-0·78). For TBLC with high or definite diagnostic confidence at MDD (39 [60%] of 65 cases), 37 (95%) were concordant with SLB diagnoses. In the 26 (40%) of 65 cases with low-confidence or unclassifiable TBLC diagnoses, SLB reclassified six (23%) to alternative high-confidence or definite MDD diagnoses. Mild-moderate airway bleeding occurred in 14 (22%) patients due to TBLC. The 90-day mortality was 2% (one of 65 patients), following acute exacerbation of idiopathic pulmonary fibrosis. INTERPRETATION High levels of agreement between TBLC and SLB for both histopathological interpretation and MDD diagnoses were shown. The TBLC MDD diagnoses made with high confidence were particularly reliable, showing excellent concordance with SLB MDD diagnoses. These data support the clinical utility of TBLC in interstitial lung disease diagnostic algorithms. Further studies investigating the safety profile of TBLC are needed. FUNDING University of Sydney, Hunter Medical Research Institute, Erbe Elektromedizin, Medtronic, Cook Medical, Rymed, Karl-Storz, Zeiss, and Olympus.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s2213-2600(19)30342-x

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 396

Metadata

Authors
Troy, L. K., Grainge, C., Corte, T. J., Williamson, J. P., Vallely, M. P., Cooper, W. A., Mahar, A., Myers, J. L., Lai, S., Mulyadi, E., Torzillo, P. J., Phillips, M. J., Jo, H. E., Webster, S. E., Lin, Q. T., Rhodes, J. E., Salamonsen, M., Wrobel, J. P., Harris, B., Don, G., Wu, P. J. C., Ng, B. J., Oldmeadow, C., Raghu, G., Lau, E. M. T., Arnold, D., Cao, C., Cashmore, A., Cleary, S., Evans, T.-J., French, B., Geis, M., Glenn, L., Hibbert, M., Ing, A., James, A., Meredith, G., Merry, C., Pudipeddi, A., Saghaie, T., Thomas, R., Thomson, C., & Twaddell, S.
Venue
The Lancet Respiratory Medicine
Publisher
Elsevier BV
Published
2020-02
Volume
8
Issue
2
Pages
171-181
ISSN
2213-2600 (ISSN-L)
OpenAlex
W2976641810
Cited by
396
References
18
FWCI
35.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic accuracy of transbronchial lung cryobiopsy for interstitial lung disease diagnosis (COLDICE): a prospective, comparative study. https://app.cochat.ai/papers/10.1016/s2213-2600(19)30342-x
The paper
Troy, L. K., Grainge, C., Corte, T. J., Williamson, J. P., Vallely, M. P., Cooper, W. A., Mahar, A., Myers, J. L., Lai, S., Mulyadi, E., Torzillo, P. J., Phillips, M. J., Jo, H. E., Webster, S. E., Lin, Q. T., Rhodes, J. E., Salamonsen, M., Wrobel, J. P., Harris, B., . . . Twaddell, S. (2020). Diagnostic accuracy of transbronchial lung cryobiopsy for interstitial lung disease diagnosis (COLDICE): a prospective, comparative study. The Lancet Respiratory Medicine. https://doi.org/10.1016/s2213-2600(19)30342-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.