Use of professional-mode flash glucose monitoring, at 3-month intervals, in adults with type 2 diabetes in general practice (GP-OSMOTIC): a pragmatic, open-label, 12-month, randomised controlled trial
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
Background Continuous glucose monitoring, either real-time (personal) or retrospective (professional mode), can identify day-to-day glucose profiles to guide management decisions for people with type 2 diabetes. We aimed to examine the effects of professional-mode flash glucose monitoring, done at 3-month intervals, in adults with type 2 diabetes in general practice. Methods We did a pragmatic, two-arm, open label, 12-month, individually randomised controlled trial (GP-OSMOTIC) in 25 general practices in Victoria, Australia. Eligible participants were adults aged 18-80 years, with type 2 diabetes diagnosed for at least 1 year and HbA 1c at least 5·5 mmol/mol (0·5%) above their target in the past month despite being prescribed at least two non-insulin glucose-lowering drugs, insulin, or both (with therapy stable for at least 4 months). We randomly assigned participants (1:1) to either use of a professional-mode flash glucose monitoring system or usual clinical care (control). All participants wore the flash glucose monitoring sensor at baseline, and electronic randomisation (using permuted block sizes of four and six, and stratified by clinic) was done after the sensor was attached. Masking of participants and treating clinicians to group allocation was not possible, but the study statistician was masked to allocation when analysing the data. At baseline, and 3, 6, 9, and 12 months, participants in the flash glucose monitoring group wore the professional-mode flash glucose mon…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Davies, M. J., D’Alessio, D. A., Fradkin, J., Kernan, W. N., Mathieu, C., Mingrone, G., Rossing, P., Tsapas, A., Wexler, D. J., & Buse, J. B. (2018) · Diabetes Care · doi:10.2337/dci18-0033 · Cited by 3,518
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Validation of Time in Range as an Outcome Measure for Diabetes Clinical Trials
Beck, R. W., Bergenstal, R. M., Riddlesworth, T. D., Kollman, C., Li, Z., Brown, A. S., & Close, K. L. (2019) · Diabetes Care · doi:10.2337/dc18-1444 · Cited by 793
Haak, T., Hanaire, H., Ajjan, R., Hermanns, N., Riveline, J.-P., & Rayman, G. (2017) · Diabetes Therapy · doi:10.1007/s13300-016-0223-6 · Cited by 623
Polonsky, W. H., Fisher, L., Schikman, C. H., Hinnen, D. A., Parkin, C. G., Jelsovsky, Z., Petersen, B., Schweitzer, M., & Wagner, R. S. (2011) · Diabetes Care · doi:10.2337/dc10-1732 · Cited by 429
Khunti, K., Ceriello, A., Cos, X., & De Block, C. (2018) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.12.004 · Cited by 200
Self-citationAllen, N. A., Fain, J. A., Braun, B., & Chipkin, S. R. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.01.006 · Cited by 182
Wright, L. A.-C., & Hirsch, I. B. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0029 · Cited by 178
Farmer, A. J., Perera, R., Ward, A., Heneghan, C., Oke, J., Barnett, A. H., Davidson, M. B., Guerci, B., Coates, V., Schwedes, U., et al. (2012) · BMJ · doi:10.1136/bmj.e486 · Cited by 156
Taylor, P. J., Thompson, C. H., & Brinkworth, G. D. (2018) · Journal of Diabetes Investigation · doi:10.1111/jdi.12807 · Cited by 105
Research works printed but not linked: 1
- Young, 2015, Examining the role of continuous glucose monitoring (CGM) in noninsulin treated type 2 diabetes, Diabetes, 64, A236
Cited by
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
Seidu, S., Kunutsor, S. K., Ajjan, R. A., & Choudhary, P. (2024) · Diabetes Care · doi:10.2337/dc23-1520 · Cited by 124
Technology in the management of type 2 diabetes: Present status and future prospects
DALY, A. B., & Hovorka, R. (2021) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14418 · Cited by 109
A review of flash glucose monitoring in type 2 diabetes
Krakauer, M., Botero, J. F., Lavalle-González, F. J., Proietti, A., & Barbieri, D. E. (2021) · Diabetology & Metabolic Syndrome · doi:10.1186/s13098-021-00654-3 · Cited by 71
Uhl, S., Choure, A., Rouse, B., Loblack, A., & Reaven, P. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgad652 · Cited by 76
Kieu, A., King, J., Govender, R. D., & Östlundh, L. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211070855 · Cited by 73
Golledge, J., Fernando, M. E., Lazzarini, P. A., Najafi, B., & Armstrong, D. G. (2020) · Sensors · doi:10.3390/s20164527 · Cited by 71
“…benefit in improving glycaemic control (HbA1c) Whether this remote monitoring improves outcomes in people at risk of developing DFD remains unclear [12] Cu ff -less blood pressure monitor Technology developed to assess this reported to be accurate in a small number of studies Currently unclear…”
BackgroundMethodRichardson, K. M., Jospe, M. R., Bohlen, L. C., Crawshaw, J., Saleh, A. A., & Schembre, S. M. (2024) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-024-01692-6 · Cited by 61
Tan, Y. Y., Suan, E., Koh, G. C. H., Suhairi, S. B., & Tyagi, S. (2024) · Archives of Public Health · doi:10.1186/s13690-024-01459-2 · Cited by 35
Lu, J., Ying, Z., Wang, P., Fu, M., Han, C., & Zhang, M. (2024) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15328 · Cited by 39
Blood Glucose Monitoring in Adults and Children with Diabetes: Update 2021
CHENG, A. Y. Y., Feig, D. S., Ho, J., Siemens, R. L., BAJAJ, H. S., Gilbert, J. D., Houlden, R. L., Kim, J., MacKay, D., Rabi, D. M., et al. (2021) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2021.07.003 · Cited by 41
Effect of Professional CGM (pCGM) on Glucose Management in Type 2 Diabetes Patients in Primary Care
Simonson, G. D., Bergenstal, R. M., Johnson, M. L., Davidson, J. L., & Martens, T. W. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296821998724 · Cited by 37
Kong, S.-Y., & Cho, M.-K. (2024) · Healthcare · doi:10.3390/healthcare12050571 · Cited by 36
“…that subdivides the types of CGM in glycemic control and considers the long-term effects and frequency of application of CGM. Additionally, we suggest that future studies should be undertaken to validate the effectiveness of CGM, focusing on devising methods that minimize these limitations.”
MethodMolfetta, S. D., Caruso, I., Cignarelli, A., Natalicchio, A., Perrini, S., Laviola, L., & Giorgino, F. (2023) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14981 · Cited by 36
Leveraging continuous glucose monitoring as a catalyst for behaviour change: a scoping review
Jospe, M. R., Richardson, K. M., Saleh, A. A., Bohlen, L. C., Crawshaw, J., Liao, Y., Konnyu, K. J., & Schembre, S. M. (2024) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-024-01622-6 · Cited by 34
Time-restricted eating improves measures of daily glycaemic control in people with type 2 diabetes
Parr, E. B., Steventon-Lorenzen, N., Johnston, R., Maniar, N., Devlin, B. L., Lim, K., & Hawley, J. A. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110569 · Cited by 35
Aronson, R., Abitbol, A., Bajaj, H. S., Cheng, A. Y. Y., Christopoulos, S., Harris, S. B., Jain, A. B., & Goldenberg, R. M. (2025) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.70008 · Cited by 33
Drovandi, A. D., Wong, S. A., Seng, L. S. D., Crowley, B. J., Alahakoon, C., Banwait, J., Fernando, M. E., & Golledge, J. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211012456 · Cited by 29
Kerr, D. E., Edelman, S. V., Vespasiani, G., & Khunti, K. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.04.006 · Cited by 26
Self-citationRizos, E. C., Markozannes, G., Charitakis, N., Filis, P., Stoimeni, A. E., Nørgaard, K., Ntzani, E. E., & Tsilidis, K. K. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0599 · Cited by 21
Bannuru, R. R., Bellini, N. J., Bergenstal, R. M., Beverly, E. A., Christofides, E. A., Cox, D. J., Ehrhardt, N. M., Fazioli, K., Fischl, A. H., Kerr, D. E., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251384318 · Cited by 20
“In contrast, Ruissen et al 41 found no significant changes from baseline to 9 months in either group on the WHO-QoL scale, and Furler et al 49 found no differences between groups at 12 months on the WHO5 scale.”
Tew, M., Catchpool, M., Furler, J., Rue, K. D. L., Clarke, P., Manski-Nankervis, J.-A. E., & Dalziel, K. (2023) · Trials · doi:10.1186/s13063-023-07177-4 · Cited by 20
Self-citationSpeight, J., Hermanns, N., Jensen, W., Kanc, K., Karagiannis, T., Law, M., Mocan, A., Rutters, F., Sturt, J. A., Zaccardi, F., et al. (2026) · Diabetologia · doi:10.1007/s00125-026-06840-0 · Cited by 15
“This recommendation is based on a meta-analysis of three RCTs [164–166] including 611 adults with type 2 diabetes (345 randomised to CGM).”
Self-citationAgarwal, S., Varghese, R. T., SAVIAN, R. E. N. A. T. O. R. E. Z. E. N. D. E., Wang, C. C. L., & Galindo, R. J. (2025) · Endocrine Practice · doi:10.1016/j.eprac.2025.05.749 · Cited by 15
Kong, X., Luo, M.-H., Cai, L., Zhang, P., Yan, R., Hu, Y., Li, H., & Ma, J. (2020) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2021.1863945 · Cited by 15
“At present, using a professional mode flash glucose monitoring (FGM) system, with data masked from users until retrieved by healthcare professionals, could provide the glycemic profiles necessary for professionals to personalize treatment [17].”
MethodYan, R., Cai, T., Jiang, L., Jing, T., Cai, L., Xie, X., Su, X., Xu, L., He, K., Cheng, L., et al. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.832102 · Cited by 13
Hua, X., Catchpool, M., Clarke, P., Blackberry, I., Chiang, J., Holmes‐Truscott, E., Jenkins, A. J., Khunti, K., O'Neal, D. N., Speight, J., et al. (2021) · Diabetic Medicine · doi:10.1111/dme.14747 · Cited by 12
Self-citationA dual-attention based coupling network for diabetes classification with heterogeneous data
Wang, L., Pan, Z., Liu, W., Wang, J., Ji, L., & Shi, D. (2023) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2023.104300 · Cited by 10
A Review on Newer Interventions for the Prevention of Diabetic Foot Disease
Tekale, S., Varma, A. R., Tekale, S., & Kumbhare, U. (2022) · Cureus · doi:10.7759/cureus.30591 · Cited by 10
“According to a recent experiment, glucose monitoring, which assesses interstitial fluid glucose, could be utilized in primary healthcare settings; however, HbA1c after 12 months indicates that it might not be superior to more conventional approaches [52].”
BackgroundCox, C. T., Sierra, S., Egan, A., McKee, D. M., & MacKay, B. J. (2023) · Cureus · doi:10.7759/cureus.48373 · Cited by 9
Speight, J., Holmes‐Truscott, E., Thuraisingam, S., Husin, H. M., Manski-Nankervis, J.-A. E., Rue, K. D. L., Ginnivan, L., Audehm, R. G., Clark, M., Khunti, K., et al. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108994 · Cited by 8
Self-citationMobile health monitoring based studies for diabetes mellitus: a review
AlShorman, O., Masadeh, M., & Alshorman, B. (2021) · Bulletin of Electrical Engineering and Informatics · doi:10.11591/eei.v10i3.3019 · Cited by 8
“CHALLENGES AND FUTURE TRENDS Achieving good healthcare services for diabetic patients is a challenging task for patients and caregivers [88], [89].”
BackgroundDepczynski, B., & Poynten, A. M. (2022) · JMIR Diabetes · doi:10.2196/35163 · Cited by 8
“The role of CGMs in type 2 diabetes (T2DM) is less clear, with variable impacts on glycemic control [11-13].”
BackgroundDeeb, A., Muammar, T., Alsaffar, H., Sedaghat, S., Hassani, N. A., Odeh, R., Alkhayyat, H., Sinani, A. A., Attia, N. A., Adhami, S., et al. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108671 · Cited by 7
Clinical Impact of Continuous Glucose Monitoring in Noninsulin Treated Type 2 Diabetes: A Review
Aleppo, G., Carlson, A. L., McGill, J. B., Alshannaq, H. A., Galindo, R. J., Kruger, D. F., Levy, C. J., Matuoka, J. Y., Ilham, S., Umpierrez, G. E., et al. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156251414980 · Cited by 6
“Overall, a trend toward improvement in diabetes empowerment, 29,51 diabetes-related stress, 35,53,54,56 and diabetes skills, con fi dence, and preparedness 30 was observed for CGM patients.”
Diamond, K. (2023) · Journal of the American Association of Nurse Practitioners · doi:10.1097/jxx.0000000000000831 · Cited by 6
Chiang, J., Manski-Nankervis, J.-A. E., Thuraisingam, S., Jenkins, A. J., O'Neal, D. N., Mair, F. S., Jani, B., Nicholl, B. I., & Furler, J. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108451 · Cited by 6
Self-citationBohlen, L. C., Crawshaw, J., Jospe, M. R., Richardson, K. M., Konnyu, K. J., & Schembre, S. M. (2025) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-025-01833-5 · Cited by 4
Schipper, S. B. J., Karagiannis, T., Zaccardi, F., Remmelzwaal, S., Blom, M. T., Dagan, N., Schoonmade, L. J., Langendam, M. W., Mb, J., Jensen, W., et al. (2026) · Diabetologia · doi:10.1007/s00125-026-06789-0 · Cited by 4
“Six trials compared devices with usual care in adults with type 2 diabetes [162–167].”
Self-citationAn overview of the FreeStyle Libre monitoring system for individuals with type 1 and type 2 diabetes
Molfetta, S. D., Cutruzzolà, A., Gnasso, A., & Irace, C. (2025) · Expert Review of Medical Devices · doi:10.1080/17434440.2025.2489494 · Cited by 4
“Diabetes-specific distress (assessed with the Problem Areas in Diabetes [PAID] scale) was comparable between the two groups [36].”
Alsifri, S. N., Almalki, A., Alsifri, S., Alsifri, N., Moatism, M., Alsifri, S., & Issak, E. R. (2022) · International Journal of Clinical Medicine · doi:10.4236/ijcm.2022.138027 · Cited by 4
Kong, S.-Y., & Cho, M. (2024) · Healthcare · doi:10.3390/healthcare12141381 · Cited by 3
Badawi, S. A. A., Alhajri, A. H. M., Altayb, N. M. O., Mohmmed, E., Hassabelrasoul, R. K. E., Mohammed, S. A. S., Mohammed, W. H. A., & Ghali, J. A. E. (2025) · Cureus · doi:10.7759/cureus.89534 · Cited by 3
“For example, Sato et al. [14] used retrospective CGM without real-time feedback and found no HbA1c benefit, whereas Furler et al. [17] employed intermittent professional CGM with clinician review and reported improved TIR.”
Influentialdos Santos, L. G. F., Corrêa, V. G. F. L., Paredes, B. D., de Paula, A. C. M. R., Santos, K. C., de Souza, S. L., Fabiano, É. D., Ramos, L. P. M., Simioni, M. D. S., & da Silveira, A. C. Z. (2023) · Revista Eletrônica Acervo Saúde · doi:10.25248/reas.e15090.2023 · Cited by 4
Holmes‐Truscott, E., Jordan, J., Churilov, L. P., Davis, W. A., Glastras, S. J., Klaic, M., Read, M., Tran‐Duy, A., O'Neal, D. N., & Ekinci, E. I. (2025) · Diabetic Medicine · doi:10.1111/dme.70057 · Cited by 2
“…have paved the way forward, 13–16 such as GP-OSMOTIC (examining primary-care based professional-mode flash glucose monitoring in type 2 diabetes) 14,15 and DAFNEplus (an update and evaluation of a type 1 diabetes structured education program), 13 both of which involve(d) collaboration be-tween…”
Self-citationMcMorrow, R., Thuraisingam, S., Furler, J., & Manski-Nankervis, J.-A. E. (2020) · Primary care diabetes · doi:10.1016/j.pcd.2020.08.001 · Cited by 2
Self-citationProfessional mode flash glucose monitoring in type 2 diabetes
Hermanns, N., Ehrmann, D., & Kulzer, B. (2019) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(19)30386-9 · Cited by 2
Li, H., Tao, S., Zhou, X., Yan, R., Yu, B., Luo, Y., Zhang, P., Kong, X., & Ma, J. (2026) · Scientific Reports · doi:10.1038/s41598-026-48843-2 · Cited by 1
“Patients with diabetes use professional mode fast glucose monitoring (FGM) system to provide personalized treatment basis for health-care professionals through retrospective analysis of the glycemic profiles 19 .”
Association between Flash Glucose Monitors and A1C: A Retrospective Pre-Post Analysis
Tekarli, M., Turner, K. M., & Witt, D. M. (2021) · INNOVATIONS in pharmacy · doi:10.24926/iip.v12i3.3977 · Cited by 1
Application of Continuous Glucose Monitoring Systems in Patients With Type 2 Diabetes Mellitus
(2022) · European Journal of Medicine · doi:10.13187/ejm.2022.1.12 · Cited by 1
M’Bemba, J. (2020) · Médecine des Maladies Métaboliques · doi:10.1016/j.mmm.2020.10.005
(2021) · The Singapore Family Physician · doi:10.33591/sfp.47.1.uo2
Hypoglycaemia in type 2 diabetes treated with pre‐mixed insulin
IDRIS, I. R., Annamalai, N., Aung, T., Binnian, I., Gibb, F. W., Malik, M. I., & Ramtoola, S. (2021) · Diabetic Medicine · doi:10.1111/dme.14684
Seidu, S., Kunutsor, S. K., Ajjan, R., & Choudhary, P. (2023) · doi:10.2337/figshare.24291334.v1
Eer, A., Hachem, M., Hearn, T., Koye, D. N., Atkinson‐Briggs, S., Jones, J. L., Eades, S., Braat, S., Twigg, S. M., Sinha, A. K., et al. (2025) · Pilot and Feasibility Studies · doi:10.1186/s40814-025-01607-7
“Many studies have shown CGM/ FGM use improves HbA1c in type 1 diabetes [13, 14, 41– 44], but few RCTs have shown improved in 2 diabetes [15, 16, 20, 45–50].”
Self-citationTew, M., Catchpool, M., Furler, J., Rue, K. D. L., Clarke, P., Manski-Nankervis, J.-A., & Dalziel, K. (2023) · Figshare · doi:10.6084/m9.figshare.22624048
Self-citationTew, M., Catchpool, M., Furler, J., Rue, K. D. L., Clarke, P., Manski-Nankervis, J.-A., & Dalziel, K. (2023) · Figshare · doi:10.6084/m9.figshare.22624054
Self-citationTew, M., Catchpool, M., Furler, J., Rue, K. D. L., Clarke, P., Manski-Nankervis, J.-A., & Dalziel, K. (2023) · Figshare · doi:10.6084/m9.figshare.22624051
Self-citationTew, M., Catchpool, M., Furler, J., Rue, K. D. L., Clarke, P., Manski-Nankervis, J.-A., & Dalziel, K. (2023) · Figshare · doi:10.6084/m9.figshare.22624042
Self-citationTew, M., Catchpool, M., Furler, J., Rue, K. D. L., Clarke, P., Manski-Nankervis, J.-A., & Dalziel, K. (2023) · Figshare · doi:10.6084/m9.figshare.22624045
Self-citationPark-Chong, H., Benrimon, M., & Smaldone, A. M. (2026) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106261451194
“QoL was assessed in the INITIATION, GP-OSMOTIC, and unnamed trials 35,44,45 using either the Audit of Diabetes Dependent Quality of Life or the Problem Areas in Diabetes scale.”
Hayek, A. A., Zahrani, W. M. A., Alotaibi, H. F., Jammal, M. E., & Dawish, M. A. A. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261489265
Holmes‐Truscott, E., Williams, A., Ng, A., Parr, E. B., Lake, A. J., Jordan, J., Manski-Nankervis, J.-A. E., Furler, J., Speight, J., & GP‐OSMOTIC Study Group (2026) · Diabetic Medicine · doi:10.1111/dme.70520
Self-citationElganduz, R., & Elbibi, N. (2026) · AlQalam Journal of Medical and Applied Sciences · doi:10.54361/ajmas.261127
Yan, R.-N., Cai, T.-T., Jiang, L.-L., Jing, T., Cai, L., Xie, X.-J., Su, X.-F., Xu, L., He, K., Cheng, L., et al. (2022) · doi:10.3389/fendo.2022.832102.s001
Metadata
- Authors
- Furler, J., O'Neal, D., Speight, J., Blackberry, I., Manski-Nankervis, J.-A., Thuraisingam, S., de La Rue, K., Ginnivan, L., Doyle, R., Holmes-Truscott, E., Khunti, K., Dalziel, K., Chiang, J., Audehm, R., Kennedy, M., Clark, M., Jenkins, A., Lake, A. J., Januszewski, A. S., Catchpool, M., Liew, D., Clarke, P., & Best, J.
- Affiliations
- The University of Melbourne (AU)
- Deakin University (AU)
- La Trobe University (AU)
- University of Leicester (GB)
- The University of Sydney (AU)
- Monash University (AU)
- Nanyang Technological University (SG)
- Corresponding author
- Furler, John
- ORCID
- Venue
- The Lancet Diabetes & Endocrinology
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 8
- Issue
- 1
- Pages
- 17-26
- ISSN
- 2213-8587 (ISSN-L)
- OpenAlex
- W2995952001
- Semantic Scholar
- cef42e6d33ab9da33dc474a3cd0833a4db5ab950
- Cited by
- 55
- References
- 28
- Citations by year
- 2026: 6 · 2025: 9 · 2024: 5 · 2023: 10 · 2022: 7 · 2021: 12 · 2020: 5
- FWCI
- 5.07
- Type
- journal article
- Language
- en
- Open access
- green
- figshare.com
- Licence
- cc-by
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- The Lancet Diabetes & Endocrinology (publishedVersion)
- PubMed (publishedVersion)
- Figshare (submittedVersion, cc-by)
- Funders
- National Health and Medical Research Council (APP1104241)
- Deakin University
- Novo Nordisk
- Roche
- AstraZeneca Australia
- Sanofi Australia
- National Institute for Health and Care Research
- Center for Outcomes Research and Evaluation, Yale School of Medicine
- National Institute for Health Research Collaboration for Leadership in Applied Health Research and Care Yorkshire and Humber
- Boehringer Ingelheim
- NIHR Leicester Biomedical Research Centre
- Abbott Diabetes Care
- Diabetes Victoria
- Manchester Biomedical Research Centre
- Sydney Medical School Foundation
- Medtronic
- Collaboration for Leadership in Applied Health Research and Care - Greater Manchester
- Sanofi
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- flash glucose monitoring, type 2 diabetes, HbA1c, glycemic control, ambulatory glucose profile, time in target glucose range, diabetes distress, general practitioner care, primary care, diabetes management, HbA1c targets, Problem Areas in Diabetes scale, HbA1c variability, HbA1c trends
- MeSH terms
- Aged, Diabetes Mellitus, Type 2, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Blood Glucose Self-Monitoring, Treatment Outcome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.