Advanced hybrid closed loop therapy versus conventional treatment in adults with type 1 diabetes (ADAPT): a randomised controlled study
Open accessAbstract
BACKGROUND Adults with type 1 diabetes who are treated with multiple daily injections of insulin plus intermittently scanned continuous glucose monitoring (isCGM) can have suboptimal glucose control. We aimed to assess the efficacy of an advanced hybrid closed loop (AHCL) system compared with such therapy in this population. METHODS The Advanced Hybrid Closed Loop Study in Adult Population with Type 1 Diabetes (ADAPT) trial is a prospective, multicentre, open-label, randomised controlled trial that involved 14 centres in three European countries (France, Germany, and the UK). We enrolled patients who were at least 18 years of age, had a type 1 diabetes duration of at least 2 years, HbA1c of at least 8% (64 mmol/mol), and were using multiple daily injections of insulin plus isCGM (cohort A) or real time continuous glucose monitoring (cohort B) for at least 3 months. Here, only results for cohort A are reported. Participants were randomly allocated 1:1 to AHCL therapy or continuation of multiple daily injections of insulin plus continuous glucose monitoring for 6 months with an investigator-blinded block randomisation procedure. Participants and treating clinicians could not be masked to the arm assignment. The primary endpoint was the between-group difference in mean HbA1c change from baseline to 6 months in the intention-to-treat population using AHCL therapy and those using multiple daily injections of insulin plus isCGM. The primary endpoint was analysed using a repeated measures random-effects model with the study arm and period as factors. Safety endpoints included the number of device deficiencies, severe hypoglycaemic events, diabetic ketoacidosis, and serious adverse events. This study is registered with ClinicalTrials.gov, NCT04235504. FINDINGS Between July 13, 2020, and March 12, 2021, 105 people were screened and 82 randomly assigned to treatment (41 in each arm). At 6 months, mean HbA1c had decreased by 1·54% (SD 0·73), from 9·00% to 7·32% in the AHCL group and 0·20% (0·80) in the multiple daily injections of insulin plus isCGM from 9·07% to 8·91% (model-based difference -1·42%, 95% CI -1·74 to -1·10; p<0·0001). No diabetic ketoacidosis, severe hypoglycaemia, or serious adverse events related to study devices occurred in either group; two severe hypoglycaemic events occurred in the run-in phase. 15 device-related non-serious adverse events occurred in the AHCL group, compared with three in the multiple daily injections of insulin plus isCGM group. Two serious adverse events occurred (one in each group), these were breast cancer (in one patient in the AHCL group) and intravitreous haemorrhage (in one patient in the multiple daily injections of insulin plus isCGM group). INTERPRETATION In people with type 1 diabetes using multiple daily injections of insulin plus isCGM and with HbA1c of at least 8%, the use of AHCL confers benefits in terms of glycaemic control beyond those that can be achieved with multiple daily injections of insulin plus isCGM. These data support wider access to AHCL in people with type 1 diabetes not at target glucose levels. FUNDING Medtronic International Trading Sàrl.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The most substantial HbA1c reduction was observed with closed-loop systems compared to MDI + CGM (−1.0 %, P-value<0.001) in the study by Choudhary et al. (2022).”
From Effectiveness of continuous glucose monitoring systems on glycemic control in adults with type 1 diabetes: A systematic review and meta-analysis (2025) · cites this paper as Choudhary et al. (2022)
In the citing paper
“the studies evaluating closed-loop systems (Choudhary et al., 2022, Matejko et al., 2022) reported significant improvements in quality of life measures.”
From Effectiveness of continuous glucose monitoring systems on glycemic control in adults with type 1 diabetes: A systematic review and meta-analysis (2025) · cites this paper as Choudhary et al., 2022
In the citing paper
“Both generation 1 low-glucose-suspend33 and generation 2 hybrid closed-loop systems improve glycated haemoglobin concentrations, the time in target range and the time below target range in children, adolescents34 and adults.35-37”
From Blood glucose monitoring devices: current considerations (2023) · cites this paper as [36]
Citations
Cites
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
State of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016–2018
Foster, N. C., Beck, R. W., Miller, K. M., Clements, M. A., Rickels, M. R., DiMeglio, L. A., Maahs, D. M., Tamborlane, W. V., Bergenstal, R., Smith, E., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0384 · Cited by 1,907
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Effect of intensive therapy on the microvascular complications of type 1 diabetes mellitus
The Writing Team for the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications Research Group (2002) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.287.19.2563 · Cited by 941
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
Epidemiology of severe hypoglycemia in the diabetes control and complications trial
(1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)80085-z · Cited by 807
Lind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705
A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes
Breton, M. D., Kanapka, L. G., Beck, R. W., Ekhlaspour, L., Forlenza, G. P., Cengiz, E., Schoelwer, M., Ruedy, K. J., Jost, E., Carria, L., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2004736 · Cited by 455
Adjusting for partially missing baseline measurements in randomized trials
White, I. R., & Thompson, S. G. (2005) · Statistics in Medicine · doi:10.1002/sim.1981 · Cited by 378
Cited by
Sorted by citations
Items 201–203 of 203
Chow, E., Yau, H. C., Saltik, A. Z. O., Hill, M., Field, M., Pollock, R. F., & de Portu, S. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261494594
Real-World MiniMed ™ 780G Advanced Hybrid Closed-Loop Performance Across the Asia-Pacific Region
Shin, J. J., Gardner, D. S.-L., CHANDRAN, S. R., Vigersky, R. A., Cordero, T. L., Niu, F., Cohen, O., Mohan, V., Jenkins, A. J., Wheeler, B. J., et al. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156261499158
Self-citationBabiker, A. M. I., Alfakeeh, S., Alsubaie, R. A., Alharbi, F., Alhammad, S., Alshammari, T., Khalaf, A. A., Almutairi, A. F., Yadav, B., Sabbah, A., et al. (2026) · International Journal of Pediatrics and Adolescent Medicine · doi:10.4103/ijpam.ijpam_120_26
Metadata
- Authors
- Choudhary, P., Kolassa, R., Keuthage, W., Kroeger, J., Thivolet, C., Evans, M., Ré, R., de Portu, S., Vorrink, L., Shin, J., Habteab, A., Castañeda, J., da Silva, J., & Cohen, O.
- Affiliations
- University of Leicester (GB)
- Hospices Civils de Lyon (FR)
- University of Cambridge (GB)
- Medtronic (Switzerland) (CH)
- Medtronic (United States) (US)
- Medtronic (Netherlands) (NL)
- Corresponding author
- Cohen, Ohad
- Venue
- The Lancet Diabetes & Endocrinology
- Publisher
- Elsevier BV
- Published
- 2022-10
- Volume
- 10
- Issue
- 10
- Pages
- 720-731
- ISSN
- 2213-8587 (ISSN-L)
- OpenAlex
- W4294215685
- Semantic Scholar
- 04dc98442e2375f436f290b55f4eb6ad236201dd
- Cited by
- 204
- References
- 41
- Citations by year
- 2026: 44 · 2025: 50 · 2024: 54 · 2023: 55 · 2022: 1
- FWCI
- 29.63
- Type
- journal article
- Language
- en
- Update notices
- erratum (2023-07-01)
- Open access
- green
- figshare.com
- Licence
- Locations
- The Lancet Diabetes & Endocrinology (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- Figshare (submittedVersion, cc-by)
- Funders
- Medtronic Inc
- King's College London
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- type 1 diabetes, multiple daily insulin injections, real-time continuous glucose monitoring, HbA1c, glycemic control, hypoglycemia, diabetic ketoacidosis, device safety, adults with type 1 diabetes, insulin pump therapy, artificial pancreas, ADAPT trial, serious adverse events
- MeSH terms
- Adult, Blood Glucose, Diabetes Mellitus, Type 1, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Insulin, Prospective Studies, Blood Glucose Self-Monitoring, Diabetic Ketoacidosis, Treatment Outcome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review