Cited by 11Diabetes Management and ResearchDiabetes Management and EducationDiabetes Treatment and Management

Effectiveness of continuous glucose monitoring systems on glycemic control in adults with type 1 diabetes: A systematic review and meta-analysis

Open access
Alfadli, Salya F., Alotaibi, Yazeed S., Aqdi, Maha J., Almozan, Latifah A., Alzubaidi, Zahra B., Altemani, Hammad A., Almutairi, Shaden D., Alabdullah, Hussain A. +3 more·2025·Metabolism Open

Abstract

Introduction: Continuous glucose monitoring (CGM) technologies have been advancing rapidly, but evidence on their comparative effectiveness stills limited to date yet. We conducted a systematic review and meta-analysis to evaluate and investigate the impact of CGM systems on glycemic control in adults with type 1 diabetes. Methods: We searched electronic literature databases from inception through April 30, 2025, for comparative studies investigating CGM systems with standard monitoring or different CGM technologies in adults with type 1 diabetes. Primary outcomes included HbA1c reduction, time in range (TIR), and hypoglycemia reduction. We performed random-effects meta-analyses, network meta-analysis, and subgroup analyses by baseline HbA1c and intervention duration. Evidence quality was assessed using GRADE methodology. Results: Twenty-seven studies with total of 2975 participants were included. CGM significantly reduced HbA1c compared to standard monitoring (mean difference: 0.38 %, 95 % CI: 0.49 to -0.27 %). TIR increased by 7.9 % (95 % CI: 5.8-10.0 %), representing 114 additional minutes daily in best range. Real-time CGM showed advantages over intermittently scanned CGM for TIR (+5.63 %, P-value<0.001) and hypoglycemia reduction (-1.28 %, P-value<0.001). Automated closed-loop systems achieved the highest ranking in network meta-analysis (SUCRA = 0.92). Benefits were greater among patients with higher baseline HbA1c (>8.5 %: 0.68 % reduction in HbA1c vs. <7.5 %: 0.24 % reduction in HbA1c, P-value = 0.009). Conclusions: CGM technologies significantly improve glycemic control in adults with type 1 diabetes, with greater benefits for those with higher baseline HbA1c. Advanced systems demonstrate progressively greater improvements, with automated closed-loop systems showing the strongest evidence of effectiveness. These findings support broader implementation of CGM technologies, with selection tailored to individual patient needs.

AI snapshot

Written from the paper’s full text.

TL;DR

This systematic review and meta-analysis of 27 RCTs (2,975 adults with type 1 diabetes) found that continuous glucose monitoring improves glycemic control versus standard monitoring, with HbA1c reduction of 0.38% and time-in-range increase of 7.9% (114 min/day). Network meta-analysis ranked automated closed-loop systems highest (SUCRA 0.92), followed by real-time CGM (0.84), with greater benefits in patients with higher baseline HbA1c.

Key findings

  • CGM versus standard monitoring reduced HbA1c (mean difference −0.38%, 95% CI 0.49 to −0.27%, P<0.001) and increased time in range by 7.9% (95% CI 5.8–10.0%, P<0.001), equal to 114 additional minutes daily in range.
  • In direct rtCGM versus isCGM comparisons, rtCGM reduced HbA1c by 0.23% (95% CI 0.34 to −0.12%, P<0.001), increased TIR by 5.36% (95% CI 3.41–7.31%, P<0.001; 77 additional minutes/day), and produced a 1.03% greater reduction in time below range (95% CI 1.45 to −0.61%, P<0.001); heterogeneity was low (I² 12.9–23.5%).
  • Network meta-analysis ranked automated hybrid closed-loop systems highest overall (SUCRA 0.92), followed by rtCGM (0.84), isCGM (0.57), sensor-augmented pump (0.39), and MDI + SMBG (0.05); closed-loop ranked first for HbA1c (P best 0.71) and TIR (P best 0.82), while rtCGM ranked first for hypoglycemia reduction (P best 0.62).
  • Subgroup analyses showed greater HbA1c reduction with higher baseline HbA1c (>8.5%: 0.68% vs <7.5%: 0.24%, P=0.009) and greater TIR improvement (>8.5%: +9.8% vs <7.5%: +5.3%, P=0.015); duration subgroup differences were not significant for HbA1c (P=0.42), while TIR peaked in 3–6-month studies (+8.4%, P=0.002).

Methods

  • PRISMA 2020 systematic review and meta-analysis; searched MEDLINE/PubMed, Scopus, CENTRAL, Google Scholar, and Web of Science from inception through April 30, 2025, for RCTs in adults ≥18 years with type 1 diabetes comparing any CGM system (rtCGM, isCGM, or automated insulin delivery/closed-loop) with SMBG or another CGM technology; 27 studies with 2,975 participants were included.
  • Random-effects meta-analyses calculated mean differences with 95% CIs; network meta-analysis ranked technologies using SUCRA values; subgroup analyses were by baseline HbA1c (<7.5%, 7.5–8.5%, >8.5%) and intervention duration (<3, 3–6, >6 months); heterogeneity used I², publication bias used funnel plots, Egger’s test, and trim-and-fill, and evidence quality used RoB 2 and GRADE.

Limitations

  • The paper states that inability to blind participants to visibly different devices caused performance bias; outcome definitions and measurement tools were heterogeneous, especially for hypoglycemia and patient-reported outcomes; few direct head-to-head comparisons limited precision; most studies lasted 3–6 months with few beyond 1 year; most studies were from high-income countries with predominantly Caucasian populations; exclusion of conference abstracts may have introduced publication bias; subgroup findings may be confounded by other patient characteristics; and adverse events, technical failures, and cost-effectiveness were inconsistently reported.
  • The paper also states that no formal multiple-testing correction was applied despite multiple outcomes and comparisons, and that older studies evaluated CGM systems now superseded by newer generations.
  • Evident from the text: reported rtCGM-versus-isCGM effects are inconsistent between the abstract (+5.63% TIR, −1.28% hypoglycemia) and results (+5.36% TIR, 1.03% greater hypoglycemia reduction), and the HbA1c confidence interval is printed as “0.49 to −0.27%,” which appears directionally inconsistent.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1016/j.metop.2025.100382

Cites

56 of 57 references verified0 citation errors · 1 not checkable

Statistics

Nothing to recompute.

Claims the paper makes

10 of 21 cited sources checked · 3 supported · 1 flagged · accuracy not yet measured

  • Findingcitation

    The DPLG system evaluated by Benhamou et al. (2019) achieved the largest improvement in TIR (+14.5%, P<0.001).

    “The DPLG system evaluated by Benhamou et al. (2019) achieved the largest improvement in TIR (+14.5 %, P-value<0.001), followed by similar benefits with other closed-loop systems.”
    Quote in the paperNot a substantial claim1 of 1 sources checked
    • cites Benhamou et al. (2019) source

      The Results report a 9.2% improvement in time in range for DBLG1 versus sensor-assisted pump therapy (p<0.0001), not 14.5%. The Discussion describes this improvement as similar to those in previous trials, rather than the largest among closed-loop systems. (LLM, conf=0.88)

      Checked by a reasoning model — may be wrong.

      Experimental — accuracy not yet measured
  • Findingcitation

    Benhamou et al. (2019) reported an 8.3% reduction in CV (P < 0.001).

    “The study by Benhamou et al. (2019) reported an 8.3 % reduction in CV (P-value<0.001)”
    Quote in the paperNot a substantial claim1 of 1 sources checked
    • cites Benhamou et al. (2019) source

      The Methods list glucose coefficient of variation (CV) as a secondary outcome, but the passages available from our copy do not report an 8.3% reduction in CV or its P-value. The Results report a 9.2% increase in time in the target glucose range, which is a different outcome. I searched for CV, coefficient of variation, and the claimed 8.3% figure. (LLM, conf=0.74)

      Experimental — accuracy not yet measured
  • Findingcitation

    Visser et al. (2021) quantified an almost 21% reduction in hypoglycemia fear scores with rtCGM compared to isCGM (P = 0.003).

    “The study by Visser et al. (2021) quantified an almost 21 % reduction in hypoglycemia fear scores with rtCGM compared to isCGM (P-value = 0.003).”
    Quote in the paperNot a substantial claim1 of 1 sources checked
    • cites Visser et al. (2021) source

      The Results and Table 2 (Additional information; page unavailable) support lower hypoglycaemia-worry scores with rtCGM than isCGM at six months. They report scores of 15.4 versus 18.0, an adjusted difference of −2.62 points and p=0.0071—not an almost 21% reduction with p=0.003. (LLM, conf=0.91)

      Experimental — accuracy not yet measured
  • Findingcitation

    Studies evaluating closed-loop systems (Choudhary et al., 2022; Matejko et al., 2022) reported significant improvements in quality of life measures.

    “the studies evaluating closed-loop systems (Choudhary et al., 2022, Matejko et al., 2022) reported significant improvements in quality of life measures.”
    Quote in the paperNot a substantial claim1 of 2 sources checked
    • cites Choudhary et al., 2022 source
    • cites Matejko et al., 2022 source
  • Findingcitation

    Garg et al. (2011) found an 8.9% reduction in MAGE (P < 0.01).

    “while Garg et al. (2011) found an 8.9 % reduction in MAGE (P-value<0.01).”
    Quote in the paperNot a substantial claim1 of 1 sources checked
    • cites Garg et al. (2011) source

      The Results (Glycemic variability indexes) report that MAGE fell during the six-month unblinded period. Table 2 (Results, Glycemic excursions; page not available) gives P < 0.001 for the blinded-versus-unblinded comparison, supporting P < 0.01, but it does not report an 8.9% reduction; the displayed MAGE values do not yield that percentage for either group. (LLM, conf=0.88)

      Experimental — accuracy not yet measured
  • Classified as probably not a substantial claim. 15
  • May combine two claims. 25
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Findingcitation

    Patient preference surveys consistently favored rtCGM systems over isCGM.

    “Patient preference surveys consistently favored rtCGM systems over isCGM (Hašková et al., 2020)”
    Quote in the paperNot a substantial claim1 of 1 sources checked
    • cites Hašková et al., 2020 source

      The Results (Secondary End Points; page unavailable) report no significant between-group differences in quality-of-life measures, but quality of life is not a patient-preference survey. The Procedures and Conclusions passages likewise do not report patient preferences. Searches for preference surveys and whether patients preferred rtCGM over isCGM found no passage addressing the claim. (LLM, conf=0.76)

      Experimental — accuracy not yet measured
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductcitation

    This systematic review and meta-analysis was conducted following PRISMA 2020 guidelines.

    “This systematic review and meta-analysis was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines [11].”
    Quote in the paperNot a substantial claim1 of 1 sources checked
    • cites [11] Page, 2021, The PRISMA 2020 statement: an updated guideline for reporting systematic reviews, Rev Esp Cardiol source
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Interpretationcitation

    Reduced diabetes distress and improved quality of life may contribute to better treatment adherence and long-term engagement with self-management behaviors.

    “Reduced diabetes distress and improved quality of life may contribute to better treatment adherence and long-term engagement with self-management behaviors [[48], [49], [50]].”
    Quote in the paperNot a substantial claim2 of 3 sources checked
    • cites [48] Schierloh, 2024, Fear of hypoglycemia and sleep in children with type 1 diabetes and their parents, Front Endocrinol source

      The Introduction discusses the effects of diabetes management and fear of hypoglycemia on sleep and quality of life, while the Results report fear-of-hypoglycemia scores. Neither section links reduced diabetes distress or improved quality of life to treatment adherence or long-term self-management engagement. Searches for adherence, long-term engagement, and related terms found no passage making that link. (LLM, conf=0.73)

      Experimental — accuracy not yet measured
    • cites [49] Barnard-Kelly, 2024, Identifying the deficiencies of currently available CGM to improve uptake and benefit, Diabet Med source
    • cites [50] Glocker, 2022, Fear of hypoglycemia and quality of life in young people with type 1 diabetes and their parents in the era of sensor glucose monitoring, Front Endocrinol source

      The Introduction (page unavailable) says psychosocial coping may affect glycemic outcomes, which supports a possible link between psychosocial well-being and diabetes management. It does not say that reduced distress or improved quality of life improves treatment adherence or long-term self-management engagement. The Discussion (page unavailable) cautions against assuming causality between psychosocial and glycemic outcomes. (LLM, conf=0.77)

      Experimental — accuracy not yet measured
  • May combine two claims.

    Findingown data

    For HbA1c outcomes in automated insulin delivery studies, three studies showed significant reductions and five found no significant difference despite TIR improvements.

    “For HbA1c outcomes, results were more variable, with three studies showing significant reductions and five finding no significant difference despite TIR improvements.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    Several automated insulin delivery studies reported additional benefits including improved quality of life, reduced glycemic variability, and improved overnight glucose control, with multiple studies highlighting nocturnal glucose management benefits.

    “Several studies reported additional benefits including improved quality of life, reduced glycemic variability, and improved overnight glucose control, with multiple studies highlighting particular benefits in nocturnal glucose management.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    In subgroup analysis by intervention duration, HbA1c reduction was 0.21% for <3 months, 0.35% for 3-6 months, and 0.41% for >6 months, with no statistically significant subgroup difference (P=0.42).

    “HbA1c reductions progressively increased from short-term studies (less than three-months: 0.21 %) to medium-term (three to six-months: 0.35 %) and long-term studies (over six-months: 0.41 %), however the difference was not statistically significant with P-value = 0.42.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    In subgroup analysis, HbA1c reduction with CGM was greater in adults with baseline HbA1c >8.5% (−0.68%) than in those with baseline HbA1c <7.5% (−0.24%), with a statistically significant subgroup difference (P=0.009).

    “Benefits were greater among patients with higher baseline HbA1c (>8.5 %: 0.68 % reduction in HbA1c vs. <7.5 %: 0.24 % reduction in HbA1c, P-value = 0.009).”
    • Also stated in: § Subgroup analyses by baseline HbA1c and intervention duration · hedged
      “When subgrouped by baseline HbA1c, a clear dose-response relationship appeared, with progressively greater HbA1c reductions as baseline values increased: 0.24 % for low HbA1c (<7.5 %), −0.39 % for moderate HbA1c (7.5–8.5 %), and −0.68 % for high HbA1c (>8.5 %). The difference between subgroups was statistically significant with P-value = 0.009.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    In network meta-analysis, isCGM consistently ranked third across all outcomes (SUCRA 0.57), followed by sensor-augmented pump therapy (SUCRA 0.39) and standard multiple daily injections with SMBG (SUCRA 0.05).

    “Intermittently scanned CGM consistently ranked third across all outcomes (SUCRA: 0.57), followed by sensor-augmented pump therapy (SUCRA: 0.39) and the standard multiple daily injections with SMBG (SUCRA: 0.05).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    In subgroup analysis, TIR improvement with CGM was greater in adults with baseline HbA1c >8.5% (+9.8%) than in those with baseline HbA1c <7.5% (+5.3%), with a statistically significant subgroup difference (P=0.015).

    “A similar pattern was observed for TIR improvements, with greater absolute increases in the high HbA1c subgroup (+9.8 %) compared to the low HbA1c subgroup (+5.3 %, P-value = 0.015 for subgroup difference).”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    In subgroup analysis by intervention duration, TIR improvement peaked in medium-duration studies (+8.4%), with a statistically significant subgroup difference (P=0.002).

    “TIR improvements peaked in medium-duration studies (+8.4 %, P-value = 0.002 for subgroup difference).”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    In network meta-analysis, rtCGM achieved the second highest overall ranking (SUCRA 0.84) and ranked first for hypoglycemia reduction (probability of being best 0.62).

    “Real-time CGM achieved the second highest overall ranking (SUCRA: 0.84) and ranked first for hypoglycemia reduction (probability of being best: 0.62).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    CGM increased time in range by 7.9% (95% CI 5.8-10.0%, P<0.001), equivalent to 114 additional minutes daily in the target range.

    “TIR increased by 7.9 % (95 % CI: 5.8–10.0 %), representing 114 additional minutes daily in best range.”
    • Also stated in: § Effect of CGM on time in range and hypoglycemia · plain
      “The pooled absolute increase in TIR was 7.9 % (95 % CI: 5.8–10.0 %, P-value<0.001), representing 114 additional minutes daily spent in the optimal glucose range (70–180 mg/dL or 3.9–10.0 mmol/L).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Direct head-to-head comparisons revealed significant advantages of real-time CGM over intermittently scanned systems for all key outcomes, especially for hypoglycemia reduction.

    “Direct head-to-head comparisons revealed significant advantages of real-time CGM over intermittently scanned systems for all key outcomes, especially regarded for hypoglycemia reduction.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    The adjusted pooled effect after trim-and-fill was −0.32% (95% CI: 0.45 to −0.19%) compared to the original estimate of −0.38% (95% CI: 0.49 to −0.27%).

    “Trim-and-fill method has identified three potentially missing studies, resulting in an adjusted pooled effect of −0.32 % (95 % CI: 0.45 to −0.19 %) compared to the original estimate of −0.38 % (95 % CI: 0.49 to −0.27 %).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Beyond glycemic metrics, we documented consistent improvements in patient-reported outcomes and glycemic variability measures.

    “Beyond glycemic metrics, we documented consistent improvements in patient-reported outcomes and glycemic variability measures.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Study design and conductown data

    For HbA1c reduction and TIR, evidence quality was moderate, mostly limited by risk of bias due to performance bias in most studies.

    “For HbA1c reduction and TIR, evidence quality was moderate (⊕⊕⊕◯), that was mostly limited by risk of bias due to performance bias in most studies.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim.

    Study design and conductnone given

    Two independent reviewers assessed risk of bias for each included study using the Cochrane Risk of Bias tool for RCTs (RoB 2).

    “Two independent reviewers assessed the risk of bias for each included study using the Cochrane Risk of Bias tool for RCTs (RoB 2), which evaluates bias across five domains: randomization process, deviations from intended interventions, missing outcome data, outcome measurement, and selective reporting.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim.

    Premisereasoning

    RCTs provide the highest level of evidence for causal inference by minimizing confounding through randomization.

    “We aimed to focus on RCTs only as they provide the highest level of evidence for causal inference by minimizing confounding through randomization.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductown data

    Reporting bias was consistently low.

    “while reporting bias was consistently low, suggesting transparent outcome reporting.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    The quality of evidence for each outcome was assessed using GRADE.

    “We assessed the quality of evidence for each outcome using the Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) approach.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    Subgroup comparisons by baseline HbA1c have inherent limitations because individual studies within subgroups may differ in unmeasured characteristics beyond baseline HbA1c levels.

    “We acknowledge that such comparisons have inherent limitations as individual studies within subgroups may differ in unmeasured characteristics beyond baseline HbA1c levels.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    CGM systems have progressed from retrospective professional devices to sophisticated real-time monitors and automated closed-loop systems that integrate with insulin delivery.

    “These systems have progressed from retrospective professional devices to sophisticated real-time monitors and automated closed-loop systems that integrate with insulin delivery [39].”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [39] Lin, 2021, Continuous glucose monitoring: a review of the evidence in type 1 and 2 diabetes mellitus source
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductreasoning

    The exclusion of conference abstracts without full-text publications may introduce publication bias.

    “Conference abstracts without full-text publications were excluded to ensure adequate data extraction and quality assessment, however we acknowledge this may introduce publication bias.”
    Quote in the paperNot a substantial claim
    • Rests on an assumption: Conference abstracts without full-text publications do not allow adequate data extraction and quality assessment.
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    Publication bias was assessed using funnel plots, Egger's test, and trim-and-fill analysis for outcomes with at least ten studies.

    “Publication bias was assessed using funnel plots, Egger's test, and trim-and-fill analysis for outcomes with at least ten studies.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim.

    Study design and conductreasoning

    Random-effects models were used to account for anticipated heterogeneity between studies.

    “We performed meta-analyses using random-effects models to account for anticipated heterogeneity between studies.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Study design and conductown data

    Most included studies had relatively short durations around three to six months, with few extending beyond one year.

    “Fourth, most included studies had relatively short durations that were around three to six months, with few extending beyond one year.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Study design and conductown data

    Limited number of direct head-to-head comparison studies for certain technology types reduced precision of some effect estimates and necessitated reliance on network meta-analysis.

    “Third, the limited number of direct head-to-head comparison studies for certain technology types reduced the precision of some effect estimates and necessitated reliance on network meta-analysis for detailed technology comparisons.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    For a typical patient, the TIR improvement represents nearly two additional hours daily spent in optimal glucose range, which forms a significant improvement in day-to-day glucose management that likely contributes to reduced glycemic variability and improved quality of life.

    “For a typical patient, this represents nearly two additional hours daily spent in optimal glucose range, which forms a significant improvement in day-to-day glucose management that likely contributes to reduced glycemic variability and improved quality of life.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: Increased TIR is associated with reduced risk of microvascular complications independent of HbA1c.
  • May combine two claims.

    Interpretationreasoning

    Both technologies offer better benefits over standard monitoring.

    “However, the slighter observed differences in HbA1c estimated by decreased 0.23 %, suggest that both technologies offer better benefits over standard monitoring, with specific technology selection could be guided by individual patient factors including hypoglycemia risk, cost considerations, and personal preferences.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Study design and conductown data

    Network meta-analysis demonstrated good consistency and transitivity.

    “While our network meta-analysis demonstrated good consistency and transitivity, direct comparative evidence would strengthen confidence in the relative effectiveness rankings.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Study design and conductown data

    Majority of studies were conducted in high-income countries with majority Caucasian populations, limiting generalizability to diverse global settings.

    “In addition to that, the majority of studies were conducted in high-income countries with majority of Caucasian populations, which is limiting the generalizability to diverse global settings.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationreasoning

    While the observed reduction is smaller than 1%, consistent benefits across studies and the maintained effect over longer durations suggest important clinical implications for long-term outcomes.

    “While our observed reduction is smaller than 1 %, the consistent benefits across studies and the maintained effect over longer durations suggest important clinical implications for long-term outcomes.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Premisecitation

    UKPDS established that each 1% reduction in HbA1c is associated with a 37% decrease in microvascular complications and a 21% reduction in diabetes-related deaths.

    “The UK Prospective Diabetes Study (UKPDS) established that each 1 % reduction in HbA1c is associated with a 37 % decrease in microvascular complications and a 21 % reduction in diabetes-related deaths [44].”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [44] Holman, 2022, A brief history of the UK prospective diabetes study: rury R holman, for the UKPDS group source
  • May combine two claims.

    Study design and conductnone given

    Reporting of adverse events, technical failures, and cost-effectiveness was inconsistent across studies, limiting ability to assess these factors.

    “We shall not forget that the reporting of adverse events, technical failures, as well as the cost-effectiveness was inconsistent across studies, limiting our ability to confidently assess these important factors.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Interpretationreasoning

    Automated insulin delivery systems may be more beneficial for patients with challenging glycemic profiles or those unable to achieve targets with standard management strategies.

    “These systems may be more beneficial for patients with challenging glycemic profiles or those unable to achieve targets with standard management strategies.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductreasoning

    Exclusion of conference abstracts without full-text publications may have introduced publication bias favoring positive results.

    “Also, our exclusion of conference abstracts without full-text publications may have introduced publication bias, possibly favoring studies with positive results that proceeded to full publication.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationreasoning

    Observed improvements in glycemic control may reflect both direct technological impact and associated behavioral adaptations.

    “The observed improvements in glycemic control may therefore reflect both the direct technological impact and associated behavioral adaptations.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim.

    Interpretationreasoning

    Differential effects by baseline HbA1c should be interpreted as suggestive rather than definitive evidence for treatment effect modification.

    “The differential effects by baseline HbA1c should therefore be interpreted as suggestive rather than definitive evidence for treatment effect modification.”
    Quote in the paperSubstantial claim
38 of 38
  • The paper relies on this without support.

    High-quality RCTs on CGM in adults with type 1 diabetes are available.

    “Given the availability of high-quality RCTs in the studied topic, we prioritized internal validity over external validity to establish clear causal relationships between CGM technologies and glycemic outcomes.”
  • The paper relies on this without support.

    HbA1c, TIR, and hypoglycemia represent clinically distinct and established endpoints in diabetes care.

    “However, we did not apply formal multiple testing corrections as our primary outcomes (HbA1c, TIR, and hypoglycemia) represent clinically distinct and established endpoints in diabetes care.”
  • The paper relies on this without support.

    Children and adolescents with type 1 diabetes have different physiological characteristics including different insulin sensitivity patterns, growth-related hormonal fluctuations, and varying adherence behaviors that may differentially impact CGM effectiveness compared to adults.

    “We excluded pediatric populations as children and adolescents with T1DM as they have different physiological characteristics including different insulin sensitivity patterns, growth-related hormonal fluctuations, and varying adherence behaviors that may differentially impact CGM effectiveness compared to adults.”
  • The paper relies on this without support.

    Pregnant women have pregnancy-specific glycemic targets and altered glucose metabolism that require specialized management.

    “Pregnant women were excluded due to pregnancy-specific glycemic targets and altered glucose metabolism that require specialized management.”
  • The paper relies on this without support.

    Type 2 diabetes has different underlying pathophysiology, management lines, and glycemic targets from type 1 diabetes.

    “T2DM participants were excluded as the underlying pathophysiology, management lines, and glycemic targets differ significantly from T1D, possibly confounding the analysis of effectiveness.”
  • The paper relies on this without support.

    Conference abstracts without full-text publications do not allow adequate data extraction and quality assessment.

    “Conference abstracts without full-text publications were excluded to ensure adequate data extraction and quality assessment, however we acknowledge this may introduce publication bias.”
  • The paper relies on this without support.

    A TIR improvement of 5% is considered clinically significant in recent consensus guidelines.

    “exceeds the threshold of 5 % considered clinically significant in recent consensus guidelines.”
  • The paper relies on this without support.

    Increased TIR is associated with reduced risk of microvascular complications independent of HbA1c.

    “This improvement is important for us given that increased TIR has been associated with reduced risk of microvascular complications independent of HbA1c.”
8 of 8

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

  • Network hypoglycemia estimate falls outside its confidence interval

    Major

    The reported interval runs from −0.79% to +1.77%, so it excludes the stated reduction of −1.28%.

  • The largest listed TIR improvement is attributed to the wrong technology

    Major

    The text attributes an increase of up to 18.5% to closed-loop or automated systems, but Table 3 assigns the 18.5% increase to a CGM-versus-SMBG study.

  • A non-RCT appears among studies said to be RCTs only

    Major

    The eligibility criteria restrict inclusion to RCTs, but Table 1 classifies the included Garg study as a Non-RCT.

  • Conflicting rtCGM-versus-isCGM TIR estimates

    Minor

    The abstract gives a 5.63% TIR advantage, while the results give 5.36% for the same technology comparison.

  • Direct rtCGM HbA1c estimate falls outside its confidence interval

    Minor

    The reported endpoints, −0.12% and +0.34%, do not contain the stated mean difference of −0.23%.

  • Automated-system HbA1c results count unreported outcomes as nonsignificant

    Minor

    The text says that, of eight studies, three found significant reductions and five found no significant difference. Table 4 instead lists HbA1c differences as not reported for Benhamou and Tauschmann, so those two cannot be counted as finding no significant difference.

6 of 6

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Dicembrini, 2021, 58, 401

Cited by

Still being checked.

Authors
Alfadli, S. F., Alotaibi, Y. S., Aqdi, M. J., Almozan, L. A., Alzubaidi, Z. B., Altemani, H. A., Almutairi, S. D., Alabdullah, H. A., Almehmadi, A. A., Alanzi, A. L., & Azzam, A. Y.
Affiliations
  • Imam Mohammad ibn Saud Islamic University (SA)
  • Jazan University (SA)
  • Umm al-Qura University (SA)
  • Northern Border University (SA)
  • King Abdulaziz University (SA)
  • Imam Abdulrahman Bin Faisal University (SA)
  • Ibn Sina National College for Medical Studies (SA)
  • American Society for Inclusion, Diversity, and Equity in Healthcare (ASIDE) (US)
Corresponding author
Azzam, Ahmed Y.
Venue
Metabolism Open
Publisher
Elsevier BV
Published
2025-09
Volume
27
Pages
100382
ISSN
2589-9368 (ISSN-L)
OpenAlex
W4412865072
Cited by
11
References
57
Citations by year
2026: 8 · 2025: 3
FWCI
2.33
Type
journal article
Language
en
Update notices
erratum (2025-09-01)
Open access
Locations
  • Metabolism Open (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • PubMed Central (submittedVersion, cc-by-nc-nd)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
continuous glucose monitoring, type 1 diabetes, glycemic control, HbA1c, time in range, hypoglycemia, flash glucose monitoring, real-time CGM, baseline HbA1c, adults

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-09.

Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-09.

Cited sources are checked by gpt-6-sol.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review