Computer-aided detection versus advanced imaging for detection of colorectal neoplasia: a systematic review and network meta-analysis
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
BACKGROUND Computer-aided detection (CADe) techniques based on artificial intelligence algorithms can assist endoscopists in detecting colorectal neoplasia. CADe has been associated with an increased adenoma detection rate, a key quality indicator, but the utility of CADe compared with existing advanced imaging techniques and distal attachment devices is unclear. METHODS For this systematic review and network meta-analysis, we did a comprehensive search of PubMed/Medline, Embase, and Scopus databases from inception to Nov 30, 2020, for randomised controlled trials investigating the effectiveness of the following endoscopic techniques in detecting colorectal neoplasia: CADe, high definition (HD) white-light endoscopy, chromoendoscopy, or add-on devices (ie, systems that increase mucosal visualisation, such as full spectrum endoscopy [FUSE] or G-EYE balloon endoscopy). We collected data on adenoma detection rates, sessile serrated lesion detection rates, the proportion of large adenomas detected per colonoscopy, and withdrawal times. A frequentist framework, random-effects network meta-analysis was done to compare artificial intelligence with chromoendoscopy, increased mucosal visualisation systems, and HD white-light endoscopy (the control group). We estimated odds ratios (ORs) for the adenoma detection rate, sessile serrated lesion detection rate, and proportion of large adenomas detected per colonoscopy, and calculated mean differences for withdrawal time, with 95% CIs. Risk of bias and certainty of evidence were assessed with the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. FINDINGS 50 randomised controlled trials, comprising 34 445 participants, were included in our main analysis (six trials of CADe, 18 of chromoendoscopy, and 26 of increased mucosal visualisation systems). HD white-light endoscopy was the control technique in all 50 studies. Compared with the control technique, the adenoma detection rate was 7·4% higher with CADe (OR 1·78 [95% CI 1·44-2·18]), 4·4% higher with chromoendoscopy (1·22 [1·08-1·39]), and 4·1% higher with increased mucosal visualisation systems (1·16 [1·04-1·28]). CADe ranked as the superior technique for adenoma detection (with moderate confidence in hierarchical ranking); cross-comparisons of CADe with other imaging techniques showed a significant increase in the adenoma detection rate with CADe versus increased mucosal visualisation systems (OR 1·54 [95% CI 1·22-1·94]; low certainty of evidence) and with CADe versus chromoendoscopy (1·45 [1·14-1·85]; moderate certainty of evidence). When focusing on large adenomas (≥10 mm) there was a significant increase in the detection of large adenomas only with CADe (OR 1·69 [95% CI 1·10-2·60], moderate certainty of evidence) when compared to HD white-light endoscopy; CADe ranked as the superior strategy for detection of large adenomas. CADe also seemed to be the superior strategy for detection of sessile serrated lesions (with moderate confidence in hierarchical ranking), although no significant increase in the sessile serrated lesion detection rate was shown (OR 1·37 [95% CI 0·65-2·88]). No significant difference in withdrawal time was reported for CADe compared with the other techniques. INTERPRETATION Based on the published literature, detection rates of colorectal neoplasia are higher with CADe than with other techniques such as chromoendoscopy or tools that increase mucosal visualisation, supporting wider incorporation of CADe strategies into community endoscopy services. FUNDING None.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wan, X., Wang, W., Liu, J., & Tong, T. (2014) · BMC Medical Research Methodology · doi:10.1186/1471-2288-14-135 · Cited by 11,735
Hutton, B., Salanti, G., Caldwell, D. M., Chaimani, A., Schmid, C. H., Cameron, C., Ioannidis, J. P. A., Straus, S., Thorlund, K., Jansen, J. P., et al. (2015) · Annals of Internal Medicine · doi:10.7326/m14-2385 · Cited by 8,269
Luo, D., Wan, X., Liu, J., & Tong, T. (2018) · Statistical Methods in Medical Research · doi:10.1177/0962280216669183 · Cited by 4,066
Graphical tools for network meta-analysis in STATA
Chaimani, A., Higgins, J. P. T., Mavridis, D., Spyridonos, P., & Salanti, G. (2013) · PLoS ONE · doi:10.1371/journal.pone.0076654 · Cited by 2,473
Adenoma detection rate and risk of colorectal cancer and death
Corley, D. A., Jensen, C. D., Marks, A. R., Zhao, W. K., Lee, J. K., Doubeni, C. A., Zauber, A. G., de Boer, J., Fireman, B. H., Schottinger, J. E., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1309086 · Cited by 2,270
Consistency and inconsistency in network meta-analysis: concepts and models for multi-arm studies
Higgins, J. P. T., Jackson, D., Barrett, J. K., Lu, G., Ades, A. E., & White, I. R. (2012) · Research Synthesis Methods · doi:10.1002/jrsm.1044 · Cited by 2,098
Salanti, G. (2012) · Research Synthesis Methods · doi:10.1002/jrsm.1037 · Cited by 1,729
Simultaneous comparison of multiple treatments: Combining direct and indirect evidence.
Caldwell, D. M., Ades, A. E., & Higgins, J. P. T. (2005) · BMJ · doi:10.1136/bmj.331.7521.897 · Cited by 1,600
Evaluating the quality of evidence from a network meta-analysis
Salanti, G., Del Giovane, C., Chaimani, A., Caldwell, D. M., & Higgins, J. P. T. (2014) · PLoS ONE · doi:10.1371/journal.pone.0099682 · Cited by 1,402
Wang, P., Berzin, T. M., Glissen Brown, J. R., Bharadwaj, S., Becq, A., Xiao, X., Liu, P., Li, L., Song, Y., Zhang, D., et al. (2019) · Gut · doi:10.1136/gutjnl-2018-317500 · Cited by 865
Turner, R. M., Davey, J., Clarke, M. J., Thompson, S. G., & Higgins, J. P. (2012) · International Journal of Epidemiology · doi:10.1093/ije/dys041 · Cited by 837
Zhao, S., Wang, S., Pan, P., Xia, T., Chang, X., Yang, X., Guo, L., Meng, Q., Yang, F., Qian, W., et al. (2019) · Gastroenterology · doi:10.1053/j.gastro.2019.01.260 · Cited by 660
Efficacy of real-time computer-aided detection of colorectal neoplasia in a randomized trial
Repici, A., Badalamenti, M., Maselli, R., Correale, L., Radaelli, F., Rondonotti, E., Ferrara, E., Spadaccini, M., Alkandari, A., Fugazza, A., et al. (2020) · Gastroenterology · doi:10.1053/j.gastro.2020.04.062 · Cited by 646
Self-citationEvaluation of inconsistency in networks of interventions
Veroniki, A. A., Vasiliadis, H. S., Higgins, J. P., & Salanti, G. (2013) · International Journal of Epidemiology · doi:10.1093/ije/dys222 · Cited by 576
Hassan, C., Spadaccini, M., Iannone, A., Maselli, R., Jovani, M., Chandrasekar, V. T., Antonelli, G., Yu, H., Areia, M., Dinis-Ribeiro, M., et al. (2021) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.06.059 · Cited by 529
Self-citationWang, P., Liu, X., Berzin, T. M., Glissen Brown, J. R., Liu, P., Zhou, C., Lei, L., Li, L., Guo, Z., Lei, S., et al. (2020) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(19)30411-x · Cited by 415
Gong, D., Wu, L., Zhang, J., Mu, G., Shen, L., Liu, J., Wang, Z., Zhou, W., An, P., Huang, X., et al. (2020) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(19)30413-3 · Cited by 393
Su, J.-R., Li, Z., Shao, X.-J., Ji, C.-R., Ji, R., Zhou, R.-C., Li, G.-C., Liu, G.-Q., He, Y.-S., Zuo, X.-L., et al. (2020) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2019.08.026 · Cited by 286
Study on detection rate of polyps and adenomas in artificial-intelligence-aided colonoscopy
Huang, J., Liu, W.-N., Zhang, Y.-Y., Bian, X.-Q., Wang, L.-J., Yang, Q., & Zhang, X.-D. (2020) · Saudi Journal of Gastroenterology · doi:10.4103/sjg.sjg_377_19 · Cited by 179
Computer-aided detection-assisted colonoscopy: classification and relevance of false positives
Hassan, C., Badalamenti, M., Maselli, R., Correale, L., Iannone, A., Radaelli, F., Rondonotti, E., Ferrara, E., Spadaccini, M., Alkandari, A., et al. (2020) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.06.021 · Cited by 81
Self-citation
Cited by
Hassan, C., Spadaccini, M., Mori, Y., Foroutan, F., Facciorusso, A., Gkolfakis, P., Tziatzios, G., Triantafyllou, K., Antonelli, G., Khalaf, K., et al. (2023) · Annals of Internal Medicine · doi:10.7326/m22-3678 · Cited by 216
Current AI technologies in cancer diagnostics and treatment
Tiwari, A., Mishra, S., & Kuo, T.-R. (2025) · Molecular Cancer · doi:10.1186/s12943-025-02369-9 · Cited by 207
Methods for clinical evaluation of artificial intelligence algorithms for medical diagnosis
Park, S. H., Han, K., Jang, H. Y., Park, J. E., Lee, J.-G., Kim, D. W., & Choi, J. (2023) · Radiology · doi:10.1148/radiol.220182 · Cited by 163
Gimeno-García, A. Z., Hernández Negrin, D., Hernández, A., Nicolás-Pérez, D., Rodríguez, E., Montesdeoca, C., Alarcon, O., Romero, R., Baute Dorta, J. L., Cedrés, Y., et al. (2023) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2022.09.029 · Cited by 78
Iacucci, M., Santacroce, G., Zammarchi, I., Maeda, Y., Del Amor, R., Meseguer, P., Kolawole, B. B., Chaudhari, U., Di Sabatino, A., Danese, S., et al. (2024) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(24)00053-0 · Cited by 73
Metadata
- Authors
- Spadaccini, M., Iannone, A., Maselli, R., Badalamenti, M., Desai, M., Chandrasekar, V. T., Patel, H. K., Fugazza, A., Pellegatta, G., Galtieri, P. A., Lollo, G., Carrara, S., Anderloni, A., Rex, D. K., Savevski, V., Wallace, M. B., Bhandari, P., Roesch, T., Gralnek, I. M., Sharma, P., Hassan, C., & Repici, A.
- Venue
- The Lancet Gastroenterology & Hepatology
- Publisher
- Elsevier BV
- Published
- 2021-10
- Volume
- 6
- Issue
- 10
- Pages
- 793-802
- ISSN
- 2468-1156 (ISSN-L)
- 2468-1253
- OpenAlex
- W3190315597
- Cited by
- 124
- References
- 20
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.