CoChat

Prediction of lung cancer risk at follow-up screening with low-dose CT: a training and validation study of a deep learning method

Open access
Huang, Peng, Lin, Cheng T, Li, Yuliang, Tammemagi, Martin C, Brock, Malcolm V, Atkar-Khattra, Sukhinder, Xu, Yanxun, Hu, Ping, Mayo, John R, Schmidt, Heidi, Gingras, Michel, Pasian, Sergio, Stewart, Lori, Tsai, Scott, Seely, Jean M, Manos, Daria, Burrowes, Paul, Bhatia, Rick, Tsao, Ming-Sound, Lam, Stephen · 2019 · The Lancet Digital Health
Cited by 148

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background Current lung cancer screening guidelines use either mean diameter, volume, or density of the largest lung nodule on the previous CT scan or appearance of a new nodule to ascertain the timing of the next CT scan. We aimed to develop an accurate screening protocol by estimating the 3-year lung cancer risk after two screening CT scans using deep learning of radiologists' CT readings and other universally available clinical information. Methods A deep learning algorithm (referred to as DeepLR) was developed using data from participants who had received at least two CT screening scans up to 2 years apart in the National Lung Screening Trial (NLST; training cohort). Double-blinded validation was done using data from participants in the Pan-Canadian Early Detection of Lung Cancer (PanCan) study (validation cohort). The primary analysis was to compare accuracy of DeepLR scores to predict lung cancer incidence at 1 year, 2 years, and 3 years with the Lung CT Screening Reporting & Data System (Lung-RADS) and volume doubling time, using time-dependent area under the receiver operating characteristic curve (AUC) analysis. Findings The training cohort consisted of 25 097 participants from NLST and the validation cohort comprised 2294 individuals from PanCan. In the validation cohort, DeepLR showed good discrimination, with 1-year, 2-year, and 3-year time-dependent AUC values for cancer diagnosis of 0·968 (SD 0·013), 0·946 (0·013), and 0·899 (0·017), respectively. Among individuals deemed high risk by DeepLR, 94%, 85%, and 71% of incident and interval lung cancers diagnosed within 1 year, 2 years, and 3 years, respectively, after the second screening CT scan were identified. Furthermore, individuals with high DeepLR scores had a significantly higher risk of mortality (hazard ratio 16·07, 95% CI 10·15–25·44; p<0·0001) among people with high scores on Lung-RADS. Interpretation DeepLR recognises patterns in both temporal and spatial changes and synergy among changes in nodule and non-nodule features. DeepLR scores could be used to accurately guide clinical management after the next scheduled repeat screening CT scan. Funding Allegheny Health Network, Johns Hopkins University, Terry Fox Research Institute, and British Columbia Cancer Foundation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s2589-7500(19)30159-1

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 148

Metadata

Authors
Huang, P., Lin, C. T., Li, Y., Tammemagi, M. C., Brock, M. V., Atkar-Khattra, S., Xu, Y., Hu, P., Mayo, J. R., Schmidt, H., Gingras, M., Pasian, S., Stewart, L., Tsai, S., Seely, J. M., Manos, D., Burrowes, P., Bhatia, R., Tsao, M.-S., & Lam, S.
Venue
The Lancet Digital Health
Publisher
Elsevier BV
Published
2019-11
Volume
1
Issue
7
Pages
e353-e362
ISSN
2589-7500 (ISSN-L)
OpenAlex
W2980626014
Cited by
148
References
5
FWCI
10.05
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prediction of lung cancer risk at follow-up screening with low-dose CT: a training and validation study of a deep learning method. https://app.cochat.ai/papers/10.1016/s2589-7500(19)30159-1
The paper
Huang, P., Lin, C. T., Li, Y., Tammemagi, M. C., Brock, M. V., Atkar-Khattra, S., Xu, Y., Hu, P., Mayo, J. R., Schmidt, H., Gingras, M., Pasian, S., Stewart, L., Tsai, S., Seely, J. M., Manos, D., Burrowes, P., Bhatia, R., Tsao, M.-S., & Lam, S. (2019). Prediction of lung cancer risk at follow-up screening with low-dose CT: a training and validation study of a deep learning method. The Lancet Digital Health. https://doi.org/10.1016/s2589-7500(19)30159-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.