Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 360

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

An artificial intelligence algorithm for prostate cancer diagnosis in whole slide images of core needle biopsies: a blinded clinical validation and deployment study

Open access
Pantanowitz, Liron, Quiroga-Garza, Gabriela M, Bien, Lilach, Heled, Ronen, Laifenfeld, Daphna, Linhart, Chaim, Sandbank, Judith, Albrecht Shach, Anat, Shalev, Varda, Vecsler, Manuela, Michelow, Pamela, Hazelhurst, Scott, Dhir, Rajiv·2020·The Lancet Digital Health

Abstract

BACKGROUND: There is high demand to develop computer-assisted diagnostic tools to evaluate prostate core needle biopsies (CNBs), but little clinical validation and a lack of clinical deployment of such tools. We report here on a blinded clinical validation study and deployment of an artificial intelligence (AI)-based algorithm in a pathology laboratory for routine clinical use to aid prostate diagnosis. METHODS: An AI-based algorithm was developed using haematoxylin and eosin (H&E)-stained slides of prostate CNBs digitised with a Philips scanner, which were divided into training (1 357 480 image patches from 549 H&E-stained slides) and internal test (2501 H&E-stained slides) datasets. The algorithm provided slide-level scores for probability of cancer, Gleason score 7-10 (vs Gleason score 6 or atypical small acinar proliferation [ASAP]), Gleason pattern 5, and perineural invasion and calculation of cancer percentage present in CNB material. The algorithm was subsequently validated on an external dataset of 100 consecutive cases (1627 H&E-stained slides) digitised on an Aperio AT2 scanner. In addition, the AI tool was implemented in a pathology laboratory within routine clinical workflow as a second read system to review all prostate CNBs. Algorithm performance was assessed with area under the receiver operating characteristic curve (AUC), specificity, and sensitivity, as well as Pearson's correlation coefficient (Pearson's r) for cancer percentage. FINDINGS: The algorithm achieved an AUC of 0·997 (95% CI 0·995 to 0·998) for cancer detection in the internal test set and 0·991 (0·979 to 1·00) in the external validation set. The AUC for distinguishing between a low-grade (Gleason score 6 or ASAP) and high-grade (Gleason score 7-10) cancer diagnosis was 0·941 (0·905 to 0·977) and the AUC for detecting Gleason pattern 5 was 0·971 (0·943 to 0·998) in the external validation set. Cancer percentage calculated by pathologists and the algorithm showed good agreement (r=0·882, 95% CI 0·834 to 0·915; p<0·0001) with a mean bias of -4·14% (-6·36 to -1·91). The algorithm achieved an AUC of 0·957 (0·930 to 0·985) for perineural invasion. In routine practice, the algorithm was used to assess 11 429 H&E-stained slides pertaining to 941 cases leading to 90 Gleason score 7-10 alerts and 560 cancer alerts. 51 (9%) cancer alerts led to additional cuts or stains being ordered, two (4%) of which led to a third opinion request. We report on the first case of missed cancer that was detected by the algorithm. INTERPRETATION: This study reports the successful development, external clinical validation, and deployment in clinical practice of an AI-based algorithm to accurately detect, grade, and evaluate clinically relevant findings in digitised slides of prostate CNBs. FUNDING: Ibex Medical Analytics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s2589-7500(20)30159-x

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 360

Metadata

Authors
Pantanowitz, L., Quiroga-Garza, G. M., Bien, L., Heled, R., Laifenfeld, D., Linhart, C., Sandbank, J., Albrecht Shach, A., Shalev, V., Vecsler, M., Michelow, P., Hazelhurst, S., & Dhir, R.
Venue
The Lancet Digital Health
Publisher
Elsevier BV
Published
2020-08
Volume
2
Issue
8
Pages
e407-e416
ISSN
2589-7500 (ISSN-L)
OpenAlex
W3045168954
Cited by
360
References
25
FWCI
15.53
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An artificial intelligence algorithm for prostate cancer diagnosis in whole slide images of core needle biopsies: a blinded clinical validation and deployment study. https://app.cochat.ai/papers/10.1016/s2589-7500(20)30159-x
The paper
Pantanowitz, L., Quiroga-Garza, G. M., Bien, L., Heled, R., Laifenfeld, D., Linhart, C., Sandbank, J., Albrecht Shach, A., Shalev, V., Vecsler, M., Michelow, P., Hazelhurst, S., & Dhir, R. (2020). An artificial intelligence algorithm for prostate cancer diagnosis in whole slide images of core needle biopsies: a blinded clinical validation and deployment study. The Lancet Digital Health. https://doi.org/10.1016/s2589-7500(20)30159-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.