Referral for disease-related visual impairment using retinal photograph-based deep learning: a proof-of-concept, model development study
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
BACKGROUND: In current approaches to vision screening in the community, a simple and efficient process is needed to identify individuals who should be referred to tertiary eye care centres for vision loss related to eye diseases. The emergence of deep learning technology offers new opportunities to revolutionise this clinical referral pathway. We aimed to assess the performance of a newly developed deep learning algorithm for detection of disease-related visual impairment. METHODS: In this proof-of-concept study, using retinal fundus images from 15 175 eyes with complete data related to best-corrected visual acuity or pinhole visual acuity from the Singapore Epidemiology of Eye Diseases Study, we first developed a single-modality deep learning algorithm based on retinal photographs alone for detection of any disease-related visual impairment (defined as eyes from patients with major eye diseases and best-corrected visual acuity of <20/40), and moderate or worse disease-related visual impairment (eyes with disease and best-corrected visual acuity of <20/60). After development of the algorithm, we tested it internally, using a new set of 3803 eyes from the Singapore Epidemiology of Eye Diseases Study. We then tested it externally using three population-based studies (the Beijing Eye study [6239 eyes], Central India Eye and Medical study [6526 eyes], and Blue Mountains Eye Study [2002 eyes]), and two clinical studies (the Chinese University of Hong Kong's Sight Threatening Diabetic Retinopathy study [971 eyes] and the Outram Polyclinic Study [1225 eyes]). The algorithm's performance in each dataset was assessed on the basis of the area under the receiver operating characteristic curve (AUC). FINDINGS: In the internal test dataset, the AUC for detection of any disease-related visual impairment was 94·2% (95% CI 93·0-95·3; sensitivity 90·7% [87·0-93·6]; specificity 86·8% [85·6-87·9]). The AUC for moderate or worse disease-related visual impairment was 93·9% (95% CI 92·2-95·6; sensitivity 94·6% [89·6-97·6]; specificity 81·3% [80·0-82·5]). Across the five external test datasets (16 993 eyes), the algorithm achieved AUCs ranging between 86·6% (83·4-89·7; sensitivity 87·5% [80·7-92·5]; specificity 70·0% [66·7-73·1]) and 93·6% (92·4-94·8; sensitivity 87·8% [84·1-90·9]; specificity 87·1% [86·2-88·0]) for any disease-related visual impairment, and the AUCs for moderate or worse disease-related visual impairment ranged between 85·9% (81·8-90·1; sensitivity 84·7% [73·0-92·8]; specificity 74·4% [71·4-77·2]) and 93·5% (91·7-95·3; sensitivity 90·3% [84·2-94·6]; specificity 84·2% [83·2-85·1]). INTERPRETATION: This proof-of-concept study shows the potential of a single-modality, function-focused tool in identifying visual impairment related to major eye diseases, providing more timely and pinpointed referral of patients with disease-related visual impairment from the community to tertiary eye hospitals. FUNDING: National Medical Research Council, Singapore.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Fleiss, J. L., & Cohen, J. (1973) · Educational and Psychological Measurement · doi:10.1177/001316447303300309 · Cited by 3,354
Collins, G. S., Reitsma, J. B., Altman, D. G., & Moons, K. G. M. (2015) · Annals of Internal Medicine · doi:10.7326/m14-0697 · Cited by 3,267
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Self-citationBourne, R. R. A., Flaxman, S. R., Braithwaite, T., Cicinelli, M. V., Das, A., Jonas, J. B., Keeffe, J., Kempen, J. H., Leasher, J., Limburg, H., et al. (2017) · The Lancet Global Health · doi:10.1016/s2214-109x(17)30293-0 · Cited by 2,213
Self-citationBourne, R., Steinmetz, J. D., Flaxman, S., Briant, P. S., Taylor, H. R., Resnikoff, S., Casson, R. J., Abdoli, A., Abu-Gharbieh, E., Afshin, A., et al. (2021) · The Lancet Global Health · doi:10.1016/s2214-109x(20)30425-3 · Cited by 1,431
Self-citationGuidelines on Diabetic Eye Care
Wong, T. Y., Sun, J., Kawasaki, R., Ruamviboonsuk, P., Gupta, N., Lansingh, V. C., Maia, M., Mathenge, W., Moreker, S., Muqit, M. M. K., et al. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.04.007 · Cited by 839
Self-citationLiu, H., Li, L., Wormstone, I. M., Qiao, C., Zhang, C., Liu, P., Li, S., Wang, H., Mou, D., Pang, R., et al. (2019) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2019.3501 · Cited by 307
Self-citation
Cited by
Benchmarking saliency methods for chest X-ray interpretation
Saporta, A., Gui, X., Agrawal, A., Pareek, A., Truong, S. Q. H., Nguyen, C. D. T., Ngo, V.-D., Seekins, J., Blankenberg, F. G., Ng, A. Y., et al. (2022) · Nature Machine Intelligence · doi:10.1038/s42256-022-00536-x · Cited by 270
“…a convolutional neural network (CNN) in predicting (1) myocardial infarction 16 and hypo-glycemia 17 from electrocardiograms, (2) visual impairment 18 , refractive error 19 and anaemia 20 from retinal photographs, (3) long-term mortality 21 and tuberculosis 22 from chest X-ray (CXR) images and…”
Ruamviboonsuk, P., Tiwari, R., Sayres, R., Nganthavee, V., Hemarat, K., Kongprayoon, A., Raman, R., Levinstein, B., Liu, Y., Schaekermann, M., et al. (2022) · The Lancet Digital Health · doi:10.1016/s2589-7500(22)00017-6 · Cited by 250
Self-citationLarge language models and their impact in ophthalmology
Betzler, B. K., Chen, H., Cheng, C.-Y., Lee, C. S., Ning, G., Song, S. J., Lee, A. Y., Kawasaki, R., van Wijngaarden, P., Grzybowski, A., et al. (2023) · The Lancet Digital Health · doi:10.1016/s2589-7500(23)00201-7 · Cited by 161
Self-citation
Metadata
- Authors
- Tham, Y.-C., Anees, A., Zhang, L., Goh, J. H. L., Rim, T. H., Nusinovici, S., Hamzah, H., Chee, M.-L., Tjio, G., Li, S., Xu, X., Goh, R., Tang, F., Cheung, C. Y.-L., Wang, Y. X., Nangia, V., Jonas, J. B., Gopinath, B., Mitchell, P., Husain, R., Lamoureux, E., Sabanayagam, C., Wang, J. J., Aung, T., Liu, Y., Wong, T. Y., & Cheng, C.-Y.
- Venue
- The Lancet Digital Health
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 3
- Issue
- 1
- Pages
- e29-e40
- ISSN
- 2589-7500 (ISSN-L)
- OpenAlex
- W3117332175
- Cited by
- 47
- References
- 9
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Referral for disease-related visual impairment using retinal photograph-based deep learning: a proof-of-concept, model development study. https://app.cochat.ai/papers/10.1016/s2589-7500(20)30271-5
- The paper
- Tham, Y.-C., Anees, A., Zhang, L., Goh, J. H. L., Rim, T. H., Nusinovici, S., Hamzah, H., Chee, M.-L., Tjio, G., Li, S., Xu, X., Goh, R., Tang, F., Cheung, C. Y.-L., Wang, Y. X., Nangia, V., Jonas, J. B., Gopinath, B., Mitchell, P., . . . Cheng, C.-Y. (2021). Referral for disease-related visual impairment using retinal photograph-based deep learning: a proof-of-concept, model development study. The Lancet Digital Health. https://doi.org/10.1016/s2589-7500(20)30271-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.