CoChat

Application of Comprehensive Artificial intelligence Retinal Expert (CARE) system: a national real-world evidence study

Open access
Lin, Duoru, Xiong, Jianhao, Liu, Congxin, Zhao, Lanqin, Li, Zhongwen, Yu, Shanshan, Wu, Xiaohang, Ge, Zongyuan, Hu, Xinyue, Wang, Bin, Fu, Meng, Zhao, Xin, Wang, Xin, Zhu, Yi, Chen, Chuan, Li, Tao, Li, Yonghao, Wei, Wenbin, Zhao, Mingwei, Li, Jianqiao, Xu, Fan, Ding, Lin, Tan, Gang, Xiang, Yi, Hu, Yongcheng, Zhang, Ping, Han, Yu, Li, Ji-Peng Olivia, Wei, Lai, Zhu, Pengzhi, Liu, Yizhi, Chen, Weirong, Ting, Daniel S W, Wong, Tien Y, Chen, Yuzhong, Lin, Haotian · 2021 · The Lancet Digital Health
Cited by 144

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Medical artificial intelligence (AI) has entered the clinical implementation phase, although real-world performance of deep-learning systems (DLSs) for screening fundus disease remains unsatisfactory. Our study aimed to train a clinically applicable DLS for fundus diseases using data derived from the real world, and externally test the model using fundus photographs collected prospectively from the settings in which the model would most likely be adopted. METHODS: In this national real-world evidence study, we trained a DLS, the Comprehensive AI Retinal Expert (CARE) system, to identify the 14 most common retinal abnormalities using 207 228 colour fundus photographs derived from 16 clinical settings with different disease distributions. CARE was internally validated using 21 867 photographs and externally tested using 18 136 photographs prospectively collected from 35 real-world settings across China where CARE might be adopted, including eight tertiary hospitals, six community hospitals, and 21 physical examination centres. The performance of CARE was further compared with that of 16 ophthalmologists and tested using datasets with non-Chinese ethnicities and previously unused camera types. This study was registered with ClinicalTrials.gov, NCT04213430, and is currently closed. FINDINGS: The area under the receiver operating characteristic curve (AUC) in the internal validation set was 0·955 (SD 0·046). AUC values in the external test set were 0·965 (0·035) in tertiary hospitals, 0·983 (0·031) in community hospitals, and 0·953 (0·042) in physical examination centres. The performance of CARE was similar to that of ophthalmologists. Large variations in sensitivity were observed among the ophthalmologists in different regions and with varying experience. The system retained strong identification performance when tested using the non-Chinese dataset (AUC 0·960, 95% CI 0·957-0·964 in referable diabetic retinopathy). INTERPRETATION: Our DLS (CARE) showed satisfactory performance for screening multiple retinal abnormalities in real-world settings using prospectively collected fundus photographs, and so could allow the system to be implemented and adopted for clinical care. FUNDING: This study was funded by the National Key R&D Programme of China, the Science and Technology Planning Projects of Guangdong Province, the National Natural Science Foundation of China, the Natural Science Foundation of Guangdong Province, and the Fundamental Research Funds for the Central Universities. TRANSLATION: For the Chinese translation of the abstract see Supplementary Materials section.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s2589-7500(21)00086-8

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 144

Metadata

Authors
Lin, D., Xiong, J., Liu, C., Zhao, L., Li, Z., Yu, S., Wu, X., Ge, Z., Hu, X., Wang, B., Fu, M., Zhao, X., Wang, X., Zhu, Y., Chen, C., Li, T., Li, Y., Wei, W., Zhao, M., Li, J., Xu, F., Ding, L., Tan, G., Xiang, Y., Hu, Y., Zhang, P., Han, Y., Li, J.-P. O., Wei, L., Zhu, P., Liu, Y., Chen, W., Ting, D. S. W., Wong, T. Y., Chen, Y., & Lin, H.
Venue
The Lancet Digital Health
Publisher
Elsevier BV
Published
2021-08
Volume
3
Issue
8
Pages
e486-e495
ISSN
2589-7500 (ISSN-L)
OpenAlex
W3185043567
Cited by
144
References
9
FWCI
11.54
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Application of Comprehensive Artificial intelligence Retinal Expert (CARE) system: a national real-world evidence study. https://app.cochat.ai/papers/10.1016/s2589-7500(21)00086-8
The paper
Lin, D., Xiong, J., Liu, C., Zhao, L., Li, Z., Yu, S., Wu, X., Ge, Z., Hu, X., Wang, B., Fu, M., Zhao, X., Wang, X., Zhu, Y., Chen, C., Li, T., Li, Y., Wei, W., Zhao, M., . . . Lin, H. (2021). Application of Comprehensive Artificial intelligence Retinal Expert (CARE) system: a national real-world evidence study. The Lancet Digital Health. https://doi.org/10.1016/s2589-7500(21)00086-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.