X-ray dark-field chest imaging for detection and quantification of emphysema in patients with chronic obstructive pulmonary disease: a diagnostic accuracy study
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Background Although advanced medical imaging technologies give detailed diagnostic information, a low-dose, fast, and inexpensive option for early detection of respiratory diseases and follow-ups is still lacking. The novel method of x-ray dark-field chest imaging might fill this gap but has not yet been studied in living humans. Enabling the assessment of microstructural changes in lung parenchyma, this technique presents a more sensitive alternative to conventional chest x-rays, and yet requires only a fraction of the dose applied in CT. We studied the application of this technique to assess pulmonary emphysema in patients with chronic obstructive pulmonary disease (COPD). Methods In this diagnostic accuracy study, we designed and built a novel dark-field chest x-ray system (Technical University of Munich, Munich, Germany)—which is also capable of simultaneously acquiring a conventional thorax radiograph (7 s, 0·035 mSv effective dose). Patients who had undergone a medically indicated chest CT were recruited from the department of Radiology and Pneumology of our site (Klinikum rechts der Isar, Technical University of Munich, Munich, Germany). Patients with pulmonary pathologies, or conditions other than COPD, that might influence lung parenchyma were excluded. For patients with different disease stages of pulmonary emphysema, x-ray dark-field images and CT images were acquired and visually assessed by five readers. Pulmonary function tests (spirometry and body plethysmography) were performed for every patient and for a subgroup of patients the measurement of diffusion capacity was performed. Individual patient datasets were statistically evaluated using correlation testing, rank-based analysis of variance, and pair-wise post-hoc comparison. Findings Between October, 2018 and December, 2019 we enrolled 77 patients. Compared with CT-based parameters (quantitative emphysema ρ=–0·27, p=0·089 and visual emphysema ρ=–0·45, p=0·0028), the dark-field signal (ρ=0·62, p<0·0001) yields a stronger correlation with lung diffusion capacity in the evaluated cohort. Emphysema assessment based on dark-field chest x-ray features yields consistent conclusions with findings from visual CT image interpretation and shows improved diagnostic performance than conventional clinical tests characterising emphysema. Pair-wise comparison of corresponding test parameters between adjacent visual emphysema severity groups (CT-based, reference standard) showed higher effect sizes. The mean effect size over the group comparisons (absent–trace, trace–mild, mild–moderate, and moderate–confluent or advanced destructive visual emphysema grades) for the COPD assessment test score is 0·21, for forced expiratory volume in 1 s (FEV 1 )/functional vital capacity is 0·25, for FEV 1 % of predicted is 0·23, for residual volume % of predicted is 0·24, for CT emphysema index is 0·35, for dark-field signal homogeneity within lungs is 0·38, for dark-field signal texture within lungs is 0·38, and for dark-field-based emphysema severity is 0·42. Interpretation X-ray dark-field chest imaging allows the diagnosis of pulmonary emphysema in patients with COPD because this technique provides relevant information representing the structural condition of lung parenchyma. This technique might offer a low radiation dose alternative to CT in COPD and potentially other lung disorders. Funding European Research Council, Deutsche Forschungsgemeinschaft, Royal Philips, and Karlsruhe Nano Micro Facility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vestbo, J., Hurd, S. S., Agustí, A. G., Jones, P. W., Vogelmeier, C., Anzueto, A., Barnes, P. J., Fabbri, L. M., Martinez, F. J., Nishimura, M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201204-0596pp · Cited by 15,983
Global Initiative for Chronic Obstructive Lung Disease (GOLD)
Rahman, M. M., & Siddiqui, M. M. R. (2017) · Anwer Khan Modern Medical College Journal · doi:10.3329/akmmcj.v7i1.31596 · Cited by 3,106
Standardisation of the measurement of lung volumes
Wanger, J., Clausen, J. L., Coates, A., Pedersen, O. F., Brusasco, V., Burgos, F., Casaburi, R., Crapo, R., Enright, P., van der Grinten, C. P. M., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035005 · Cited by 2,768
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
Pfeiffer, F., Weitkamp, T., Bunk, O., & David, C. (2006) · Nature Physics · doi:10.1038/nphys265 · Cited by 1,855
Self-citationHard-X-ray dark-field imaging using a grating interferometer
Pfeiffer, F., Bech, M., Bunk, O., Kraft, P., Eikenberry, E. F., Brönnimann, C., Grünzweig, C., & Dávid, C. (2008) · Nature Materials · doi:10.1038/nmat2096 · Cited by 1,228
Self-citationLynch, D. A., Austin, J. H. M., Hogg, J. C., Grenier, P. A., Kauczor, H.-U., Bankier, A. A., Barr, R. G., Colby, T. V., Galvin, J. R., Gevenois, P. A., et al. (2015) · Radiology · doi:10.1148/radiol.2015141579 · Cited by 658
Self-citationClinical and Radiologic Disease in Smokers With Normal Spirometry
Regan, E. A., Lynch, D. A., Curran-Everett, D., Curtis, J. L., Austin, J. H. M., Grenier, P. A., Kauczor, H.-U., Bailey, W. C., DeMeo, D. L., Casaburi, R. H., et al. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.2735 · Cited by 465
Self-citationLarke, F. J., Kruger, R. L., Cagnon, C. H., Flynn, M. J., McNitt‐Gray, M. F., Wu, X., Judy, P. F., & CODY, D. D. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.6533 · Cited by 259
CT-based Visual Classification of Emphysema: Association with Mortality in the COPDGene Study
Lynch, D. A., Moore, C. M., Wilson, C., Nevrekar, D., Jennermann, T., Humphries, S. M., Austin, J. H. M., Grenier, P. A., Kauczor, H.-U., Han, M. K., et al. (2018) · Radiology · doi:10.1148/radiol.2018172294 · Cited by 217
Self-citationMartinez, C. H., Mannino, D. M., Jaimes, F. A., Curtis, J. L., Han, M. K., Hansel, N. N., & Diaz, A. A. (2015) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201506-388oc · Cited by 214
Inverse geometry for grating-based x-ray phase-contrast imaging
Donath, T., Chabior, M., Pfeiffer, F., Bunk, O., Reznikova, E. F., Mohr, J., Hempel, E., Popescu, Ş., Hoheisel, M., Schuster, M., et al. (2009) · Journal of Applied Physics · doi:10.1063/1.3208052 · Cited by 186
Self-citationInhibition of LTβR signalling activates WNT-induced regeneration in lung
Conlon, T. M., John-Schuster, G., Heide, D., Pfister, D., Lehmann, M., Hu, Y., Ertüz, Z., Lopez, M. A., Ansari, M., Strunz, M., et al. (2020) · Nature · doi:10.1038/s41586-020-2882-8 · Cited by 179
In-vivo dark-field and phase-contrast x-ray imaging
Bech, M., Tapfer, A., Velroyen, A., Yaroshenko, A., Pauwels, B., Hostens, J., Bruyndonckx, P., Sasov, A., & Pfeiffer, F. (2013) · Scientific Reports · doi:10.1038/srep03209 · Cited by 176
Self-citationMeasurement of lung volumes by plethysmography
Coates, A., Peslin, R., Rodenstein, D., & Stocks, J. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10061415 · Cited by 174
Diagnosis and early detection of COPD using spirometry.
Johns, D. P., Walters, J. A., & Walters, E. H. (2014) · PubMed · doi:10.3978/j.issn.2072-1439.2014.08.18 · Cited by 169
Labaki, W. W., Martínez, C. H., Martínez, F. J., Galbán, C. J., Ross, B. D., Washko, G. R., Barr, R. G., Regan, E. A., Coxson, H. O., Hoffman, E. A., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201703-0451pp · Cited by 167
Effects of CT Section Thickness and Reconstruction Kernel on Emphysema Quantification
Gierada, D. S., Bierhals, A. J., Choong, C. K. C., Bartel, S. T., Ritter, J. H., Das, N. A., Hong, C., Pilgram, T. K., Bae, K. T., Whiting, B. R., et al. (2009) · Academic Radiology · doi:10.1016/j.acra.2009.08.007 · Cited by 159
Yaroshenko, A., Meinel, F. G., Bech, M., Tapfer, A., Velroyen, A., Schleede, S., Auweter, S., Bohla, A., Yildirim, A. Ö., Nikolaou, K., et al. (2013) · Radiology · doi:10.1148/radiology.13122413 · Cited by 119
Self-citationX-ray dark-field imaging of the human lung—A feasibility study on a deceased body
Willer, K., Fingerle, A. A., Gromann, L. B., Marco, F. D., Herzen, J., Achterhold, K., Gleich, B., Muenzel, D., Scherer, K., Renz, M., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0204565 · Cited by 103
Self-citationIn-vivo X-ray Dark-Field Chest Radiography of a Pig
Gromann, L. B., Marco, F. D., Willer, K., Noël, P. B., Scherer, K., Renger, B. C., Gleich, B., Achterhold, K., Fingerle, A. A., Muenzel, D., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-05101-w · Cited by 101
Self-citationGrating interferometer based scanning setup for hard x-ray phase contrast imaging
Kottler, C., Pfeiffer, F., Bunk, O., Grünzweig, C., & Dávid, C. (2007) · Review of Scientific Instruments · doi:10.1063/1.2723064 · Cited by 97
Self-citationImproved In vivo Assessment of Pulmonary Fibrosis in Mice using X-Ray Dark-Field Radiography
Yaroshenko, A., Hellbach, K., Yildirim, A. Ö., Conlon, T. M., Fernandez, I. E., Bech, M., Velroyen, A., Meinel, F. G., Auweter, S., Reiser, M., et al. (2015) · Scientific Reports · doi:10.1038/srep17492 · Cited by 95
Self-citationX-ray Dark-field Radiography - In-Vivo Diagnosis of Lung Cancer in Mice
Scherer, K., Yaroshenko, A., Bölükbas, D. A., Gromann, L. B., Hellbach, K., Meinel, F. G., Braunagel, M., von Berg, J., Eickelberg, O., Reiser, M. F., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-00489-x · Cited by 92
Self-citationSlit‐scanning differential x‐ray phase‐contrast mammography: Proof‐of‐concept experimental studies
Koehler, T., Daerr, H., Martens, G., Kühn, N., Löscher, S., van Stevendaal, U., & Roessl, E. (2015) · Medical Physics · doi:10.1118/1.4914420 · Cited by 85
Self-citationBeam hardening effects in grating‐based x‐ray phase‐contrast imaging
Chabior, M., Donath, T., Dávid, C., Bunk, O., Schuster, M., Schroer, C. G., & Pfeiffer, F. (2011) · Medical Physics · doi:10.1118/1.3553408 · Cited by 72
Self-citationImproved Diagnosis of Pulmonary Emphysema Using In Vivo Dark-Field Radiography
Meinel, F. G., Yaroshenko, A., Hellbach, K., Bech, M., Müller, M., Velroyen, A., Bamberg, F., Eickelberg, O., Nikolaou, K., Reiser, M. F., et al. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000067 · Cited by 67
Self-citationLarge field-of-view tiled grating structures for X-ray phase-contrast imaging
Schröter, T. J., Koch, F., Meyer, P., Kunka, D., Meiser, J., Willer, K., Gromann, L. B., Marco, F. D., Herzen, J., Noël, P. B., et al. (2017) · Review of Scientific Instruments · doi:10.1063/1.4973632 · Cited by 54
Self-citationYaroshenko, A., Pritzke, T., Koschlig, M., Kamgari, N., Willer, K., Gromann, L. B., Auweter, S., Hellbach, K., Reiser, M. F., Eickelberg, O., et al. (2016) · Scientific Reports · doi:10.1038/srep24269 · Cited by 52
Self-citationFacilitated Diagnosis of Pneumothoraces in Newborn Mice Using X-ray Dark-Field Radiography
Hellbach, K., Yaroshenko, A., Willer, K., Pritzke, T., Baumann, A. B., Hesse, N., Auweter, S., Reiser, M. F., Eickelberg, O., Pfeiffer, F., et al. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000285 · Cited by 48
Self-citationOh, A. S., Strand, M. J., Pratte, K., Regan, E. A., Humphries, S. M., Crapo, J. D., Lynch, D. A., & For the Genetic Epidemiology of COPDGene Investigators (2020) · Radiology · doi:10.1148/radiol.2020192429 · Cited by 47
Optimization of tube voltage in X-ray dark-field chest radiography
Sauter, A. P., Andrejewski, J., Marco, F. D., Willer, K., Gromann, L. B., Noichl, W., Kriner, F., Fischer, F., Braun, C., Koehler, T., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-45256-2 · Cited by 33
Self-citationFingerle, A. A., Marco, F. D., Andrejewski, J., Willer, K., Gromann, L. B., Noichl, W., Kriner, F., Fischer, F., Braun, C., Maack, H.-I., et al. (2019) · European Radiology Experimental · doi:10.1186/s41747-019-0104-7 · Cited by 22
Self-citationMarco, F. D., Willer, K., Gromann, L. B., Andrejewski, J., Hellbach, K., Bähr, A., Dmochewitz, M., Koehler, T., Maack, H.-I., Pfeiffer, F., et al. (2019) · PLoS ONE · doi:10.1371/journal.pone.0217858 · Cited by 16
Self-citationCOUNTERPOINT: Should Chest CT Be Part of Routine Clinical Care for COPD? No
Han, M. K. (2018) · CHEST Journal · doi:10.1016/j.chest.2018.08.1057 · Cited by 6
POINT: Should Chest CT Be Part of Routine Clinical Care for COPD? Yes
Washko, G. R. (2018) · CHEST Journal · doi:10.1016/j.chest.2018.08.1053 · Cited by 4
Metadata
- Authors
- Willer, K., Fingerle, A. A., Noichl, W., De Marco, F., Frank, M., Urban, T., Schick, R., Gustschin, A., Gleich, B., Herzen, J., Koehler, T., Yaroshenko, A., Pralow, T., Zimmermann, G. S., Renger, B., Sauter, A. P., Pfeiffer, D., Makowski, M. R., Rummeny, E. J., Grenier, P. A., & Pfeiffer, F.
- Venue
- The Lancet Digital Health
- Publisher
- Elsevier BV
- Published
- 2021-11
- Volume
- 3
- Issue
- 11
- Pages
- e733-e744
- ISSN
- 2589-7500 (ISSN-L)
- OpenAlex
- W3207985869
- Cited by
- 171
- References
- 36
- FWCI
- 20.38
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.