Individualising intensive systolic blood pressure reduction in hypertension using computational trial phenomaps and machine learning: a post-hoc analysis of randomised clinical trials
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Background The cardiovascular benefits of intensive systolic blood pressure control vary across clinical populations tested in large randomised clinical trials. We aimed to evaluate the application of machine learning to clinical trials of patients without and with type 2 diabetes to define the personalised cardiovascular benefit of intensive control of systolic blood pressure. Methods In SPRINT, a trial of intensive (systolic blood pressure <120 mm Hg) versus standard (systolic blood pressure <140 mm Hg) systolic blood pressure control in patients without type 2 diabetes, we defined a phenotypic representation of the study population using 59 baseline variables. We extracted personalised treatment effect estimates for the primary outcome, time-to-first major adverse cardiovascular event (MACE; cardiovascular death, myocardial infarction or acute coronary syndrome, stroke, and acute decompensated heart failure), through iterative Cox regression analyses providing average hazard ratio (HR) estimates weighted for the phenotypic distance of each participant from the index patient of each iteration. Next, we trained an extreme gradient boosting algorithm (known as XGBoost) to predict the personalised effect of intensive systolic blood pressure control using features most consistently linked to increased personalised benefit, before evaluating its performance in the ACCORD BP trial of patients with type 2 diabetes randomly assigned to receive intensive versus standard systolic blood pressure control. We stratified patients based on their predicted treatment effect, and key demographic groups (age, sex, cardiovascular disease, and smoking). We assessed the presence of heterogeneity with an interaction test, and assessed the performance of the algorithm in a simulation analysis of SPRINT in the presence or absence of an artificially introduced heterogeneous treatment effect. Findings From SPRINT, we included all 9361 study participants (mean age 67·9 years [SD 9·4], 3332 [35·6%] female) who underwent randomisation to either intensive (n=4678) or standard (n=4683) treatment. The median individualised HR for MACE was 0·63 (IQR 0·53–0·78). An eight-feature tool built for this analysis to predict personalised benefit in SPRINT was externally tested in ACCORD BP (4733 participants (mean age 62·7 years [SD 6·7], 2258 [47·7%] female), wherein it successfully identified individuals with differential benefit from intensive versus standard systolic blood pressure control (adjusted HR for MACE of 0·70 [95% CI 0·55–0·90] in individuals with above-median MACE benefit versus 1·05 [95% CI 0·84–1·32] for below-median predicted benefit; p interaction =0·0184). Subgroup analysis based on age (<65 years: HR 0·89 [95% CI 0·71–1·12]; ≥65 years: 0·85 [0·67–1·09]), sex (male: 0·89 [0·72–1·10]; female: 0·85 [0·65–1·10]), established cardiovascular disease (no: 0·89 [0·70–1·14]; yes: 0·84 [0·67–1·06]), or active smoking (no: 0·85 [0·71–1·02]; yes: 1·01 [0·64–1·60]) did not identify groups with heterogeneity of treatment effect. In a simulation analysis of SPRINT, the proposed algorithm detected groups with heterogeneous treatment effects in the presence, but not absence, of simulated subgroup differences. Interpretation By use of machine learning to define an individual's personalised benefit through phenotypic representations of clinical trials, we created a practical tool for individualising the selection of intensive versus standard systolic blood pressure control in patients without and with type 2 diabetes. Funding National Heart, Lung, and Blood Institute of the US National Institutes of Health.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
From local explanations to global understanding with explainable AI for trees
Lundberg, S. M., Erion, G., Chen, H., DeGrave, A., Prutkin, J. M., Nair, B., Katz, R., Himmelfarb, J., Bansal, N., & Lee, S.-I. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-019-0138-9 · Cited by 10,551
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
XGBoost: A Scalable Tree Boosting System
Chen, T., & Guestrin, C. (2016) · arXiv · doi:10.48550/arxiv.1603.02754 · Cited by 7,104
A Randomized Trial of Intensive versus Standard Blood-Pressure Control
The SPRINT Research Group (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1511939 · Cited by 6,325
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000066 · Cited by 4,347
Effects of intensive blood-pressure control in type 2 diabetes mellitus
(2010) · New England Journal of Medicine · doi:10.1056/nejmoa1001286 · Cited by 3,598
Estimation and Inference of Heterogeneous Treatment Effects using Random Forests
Wager, S., & Athey, S. (2018) · Journal of the American Statistical Association · doi:10.1080/01621459.2017.1319839 · Cited by 2,917
Recursive partitioning for heterogeneous causal effects
Athey, S., & Imbens, G. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1510489113 · Cited by 1,586
Blood Pressure Lowering in Type 2 Diabetes: A Systematic Review and Meta-analysis
Emdin, C. A., Rahimi, K., Neal, B., Callender, T., Perkovic, V., & Patel, A. (2015) · JAMA · doi:10.1001/jama.2014.18574 · Cited by 854
Effect of systolic and diastolic blood pressure on cardiovascular outcomes
Flint, A. C., Conell, C., Ren, X., Banki, N. M., Chan, S. L., Rao, V. A., Melles, R. B., & Bhatt, D. L. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1803180 · Cited by 684
Cited by
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Transforming Cardiovascular Care With Artificial Intelligence: From Discovery to Practice
Khera, R., Oikonomou, E. K., Nadkarni, G. N., Morley, J. R., Wiens, J., Butte, A. J., & Topol, E. J. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2024.05.003 · Cited by 264
Self-citationMachine learning in precision diabetes care and cardiovascular risk prediction
Oikonomou, E. K., & Khera, R. (2023) · Cardiovascular Diabetology · doi:10.1186/s12933-023-01985-3 · Cited by 190
Self-citationMuse, E. D., & Topol, E. J. (2024) · Cell Metabolism · doi:10.1016/j.cmet.2024.02.002 · Cited by 50
Artificial intelligence-enhanced patient evaluation: bridging art and science
Oikonomou, E. K., & Khera, R. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae415 · Cited by 34
Self-citation
Metadata
- Authors
- Oikonomou, E. K., Spatz, E. S., Suchard, M. A., & Khera, R.
- Venue
- The Lancet Digital Health
- Publisher
- Elsevier BV
- Published
- 2022-11
- Volume
- 4
- Issue
- 11
- Pages
- e796-e805
- ISSN
- 2589-7500 (ISSN-L)
- OpenAlex
- W4307840950
- Cited by
- 71
- References
- 12
- FWCI
- 9.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Individualising intensive systolic blood pressure reduction in hypertension using computational trial phenomaps and machine learning: a post-hoc analysis of randomised clinical trials. https://app.cochat.ai/papers/10.1016/s2589-7500(22)00170-4
- The paper
- Oikonomou, E. K., Spatz, E. S., Suchard, M. A., & Khera, R. (2022). Individualising intensive systolic blood pressure reduction in hypertension using computational trial phenomaps and machine learning: a post-hoc analysis of randomised clinical trials. The Lancet Digital Health. https://doi.org/10.1016/s2589-7500(22)00170-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.