Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 358

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Artificial intelligence for breast cancer detection in screening mammography in Sweden: a prospective, population-based, paired-reader, non-inferiority study

Open access
Dembrower, Karin, Crippa, Alessio, Colón, Eugenia, Eklund, Martin, Strand, Fredrik·2023·The Lancet Digital Health

Abstract

BACKGROUND: Artificial intelligence (AI) as an independent reader of screening mammograms has shown promise, but there are few prospective studies. Our aim was to conduct a prospective clinical trial to examine how AI affects cancer detection and false positive findings in a real-world setting. METHODS: ScreenTrustCAD was a prospective, population-based, paired-reader, non-inferiority study done at the Capio Sankt Göran Hospital in Stockholm, Sweden. Consecutive women without breast implants aged 40-74 years participating in population-based screening in the geographical uptake area of the study hospital were included. The primary outcome was screen-detected breast cancer within 3 months of mammography, and the primary analysis was to assess non-inferiority (non-inferiority margin of 0·15 relative reduction in breast cancer diagnoses) of double reading by one radiologist plus AI compared with standard-of-care double reading by two radiologists. We also assessed single reading by AI alone and triple reading by two radiologists plus AI compared with standard-of-care double reading by two radiologists. This study is registered with ClinicalTrials.gov, NCT04778670. FINDINGS: From April 1, 2021, to June 9, 2022, 58 344 women aged 40-74 years underwent regular mammography screening, of whom 55 581 were included in the study. 269 (0·5%) women were diagnosed with screen-detected breast cancer based on an initial positive read: double reading by one radiologist plus AI was non-inferior for cancer detection compared with double reading by two radiologists (261 [0·5%] vs 250 [0·4%] detected cases; relative proportion 1·04 [95% CI 1·00-1·09]). Single reading by AI (246 [0·4%] vs 250 [0·4%] detected cases; relative proportion 0·98 [0·93-1·04]) and triple reading by two radiologists plus AI (269 [0·5%] vs 250 [0·4%] detected cases; relative proportion 1·08 [1·04-1·11]) were also non-inferior to double reading by two radiologists. INTERPRETATION: Replacing one radiologist with AI for independent reading of screening mammograms resulted in a 4% higher non-inferior cancer detection rate compared with radiologist double reading. Our study suggests that AI in the study setting has potential for controlled implementation, which would include risk management and real-world follow-up of performance. FUNDING: Swedish Research Council, Swedish Cancer Society, Region Stockholm, and Lunit.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s2589-7500(23)00153-x

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 358

Metadata

Authors
Dembrower, K., Crippa, A., Colón, E., Eklund, M., & Strand, F.
Venue
The Lancet Digital Health
Publisher
Elsevier BV
Published
2023-10
Volume
5
Issue
10
Pages
e703-e711
ISSN
2589-7500 (ISSN-L)
OpenAlex
W4386533578
Cited by
358
References
18
FWCI
31.54
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial intelligence for breast cancer detection in screening mammography in Sweden: a prospective, population-based, paired-reader, non-inferiority study. https://app.cochat.ai/papers/10.1016/s2589-7500(23)00153-x
The paper
Dembrower, K., Crippa, A., Colón, E., Eklund, M., & Strand, F. (2023). Artificial intelligence for breast cancer detection in screening mammography in Sweden: a prospective, population-based, paired-reader, non-inferiority study. The Lancet Digital Health. https://doi.org/10.1016/s2589-7500(23)00153-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.