The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
External Evaluation of 3 Commercial Artificial Intelligence Algorithms for Independent Assessment of Screening Mammograms
Open accessAbstract
Importance: A computer algorithm that performs at or above the level of radiologists in mammography screening assessment could improve the effectiveness of breast cancer screening. Objective: To perform an external evaluation of 3 commercially available artificial intelligence (AI) computer-aided detection algorithms as independent mammography readers and to assess the screening performance when combined with radiologists. Design, Setting, and Participants: This retrospective case-control study was based on a double-reader population-based mammography screening cohort of women screened at an academic hospital in Stockholm, Sweden, from 2008 to 2015. The study included 8805 women aged 40 to 74 years who underwent mammography screening and who did not have implants or prior breast cancer. The study sample included 739 women who were diagnosed as having breast cancer (positive) and a random sample of 8066 healthy controls (negative for breast cancer). Main Outcomes and Measures: Positive follow-up findings were determined by pathology-verified diagnosis at screening or within 12 months thereafter. Negative follow-up findings were determined by a 2-year cancer-free follow-up. Three AI computer-aided detection algorithms (AI-1, AI-2, and AI-3), sourced from different vendors, yielded a continuous score for the suspicion of cancer in each mammography examination. For a decision of normal or abnormal, the cut point was defined by the mean specificity of the first-reader radiologists (96.6%). Results: The median age of study participants was 60 years (interquartile range, 50-66 years) for 739 women who received a diagnosis of breast cancer and 54 years (interquartile range, 47-63 years) for 8066 healthy controls. The cases positive for cancer comprised 618 (84%) screen detected and 121 (16%) clinically detected within 12 months of the screening examination. The area under the receiver operating curve for cancer detection was 0.956 (95% CI, 0.948-0.965) for AI-1, 0.922 (95% CI, 0.910-0.934) for AI-2, and 0.920 (95% CI, 0.909-0.931) for AI-3. At the specificity of the radiologists, the sensitivities were 81.9% for AI-1, 67.0% for AI-2, 67.4% for AI-3, 77.4% for first-reader radiologist, and 80.1% for second-reader radiologist. Combining AI-1 with first-reader radiologists achieved 88.6% sensitivity at 93.0% specificity (abnormal defined by either of the 2 making an abnormal assessment). No other examined combination of AI algorithms and radiologists surpassed this sensitivity level. Conclusions and Relevance: To our knowledge, this study is the first independent evaluation of several AI computer-aided detection algorithms for screening mammography. The results of this study indicated that a commercially available AI computer-aided detection algorithm can assess screening mammograms with a sufficient diagnostic performance to be further evaluated as an independent reader in prospective clinical trials. Combining the first readers with the best algorithm identified more cases positive for cancer than combining the first readers with second readers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Mammographic Density and the Risk and Detection of Breast Cancer
Boyd, N. F., Guo, H., Martin, L. J., Sun, L., Stone, J., Fishell, E., Jong, R. A., Hislop, G., Chiarelli, A., Minkin, S., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa062790 · Cited by 2,478
Screening, T. I. U. P. O. B. C., Marmot, M. G., Altman, D. G., Cameron, D. A., Dewar, J. A., Thompson, S. G., & Wilcox, M. (2013) · British Journal of Cancer · doi:10.1038/bjc.2013.177 · Cited by 1,069
Rodriguez-Ruiz, A., Lång, K., Gubern-Merida, A., Broeders, M., Gennaro, G., Clauser, P., Helbich, T. H., Chevalier, M., Tan, T., Mertelmeier, T., et al. (2019) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djy222 · Cited by 692
Deep Neural Networks Improve Radiologists’ Performance in Breast Cancer Screening
Wu, N., Phang, J., Park, J., Shen, Y., Huang, Z., Zorin, M., Jastrzebski, S., Fevry, T., Katsnelson, J., Kim, E., et al. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2945514 · Cited by 689
Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678
IEEE Transactions on Medical Imaging
(2025) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.42 · Cited by 670
Lehman, C. D., Arao, R. F., Sprague, B. L., Lee, J. M., Buist, D. S. M., Kerlikowske, K., Henderson, L. M., Onega, T., Tosteson, A. N. A., Rauscher, G. H., et al. (2017) · Radiology · doi:10.1148/radiol.2016161174 · Cited by 665
Detection of Breast Cancer with Mammography: Effect of an Artificial Intelligence Support System
Rodríguez-Ruiz, A., Krupinski, E., Mordang, J.-J., Schilling, K., Heywang-Köbrunner, S. H., Sechopoulos, I., & Mann, R. M. (2019) · Radiology · doi:10.1148/radiol.2018181371 · Cited by 602
Kim, H.-E., Kim, H. H., Han, B.-K., Kim, K. H., Han, K., Nam, H., Lee, E. H., & Kim, E.-K. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30003-0 · Cited by 525
Cited by
Lång, K., Josefsson, V., Larsson, A.-M., Larsson, S., Högberg, C., Sartor, H., Hofvind, S., Andersson, I., & Rosso, A. (2023) · The Lancet Oncology · doi:10.1016/s1470-2045(23)00298-x · Cited by 598
Artificial intelligence for clinical oncology
Kann, B. H., Hosny, A., & Aerts, H. J. W. L. (2021) · Cancer Cell · doi:10.1016/j.ccell.2021.04.002 · Cited by 370
Dembrower, K., Crippa, A., Colón, E., Eklund, M., & Strand, F. (2023) · The Lancet Digital Health · doi:10.1016/s2589-7500(23)00153-x · Cited by 358
Self-citationFreeman, K., Geppert, J., Stinton, C., Todkill, D., Johnson, S., Clarke, A., & Taylor-Phillips, S. (2021) · BMJ · doi:10.1136/bmj.n1872 · Cited by 338
Machine learning in clinical decision making
Adlung, L., Cohen, Y., Mor, U., & Elinav, E. (2021) · Med · doi:10.1016/j.medj.2021.04.006 · Cited by 282
Metadata
- Authors
- Salim, M., Wåhlin, E., Dembrower, K., Azavedo, E., Foukakis, T., Liu, Y., Smith, K., Eklund, M., & Strand, F.
- Venue
- JAMA Oncology
- Publisher
- American Medical Association (AMA)
- Published
- 2020-10-01
- Volume
- 6
- Issue
- 10
- Pages
- 1581
- ISSN
- 2374-2437 (ISSN-L)
- OpenAlex
- W3080906432
- Cited by
- 288
- References
- 21
- FWCI
- 14.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: External Evaluation of 3 Commercial Artificial Intelligence Algorithms for Independent Assessment of Screening Mammograms. https://app.cochat.ai/papers/10.1001/jamaoncol.2020.3321
- The paper
- Salim, M., Wåhlin, E., Dembrower, K., Azavedo, E., Foukakis, T., Liu, Y., Smith, K., Eklund, M., & Strand, F. (2020). External Evaluation of 3 Commercial Artificial Intelligence Algorithms for Independent Assessment of Screening Mammograms. JAMA Oncology. https://doi.org/10.1001/jamaoncol.2020.3321
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.