Abstract
BACKGROUND: Recent studies have shown that using no-touch disinfection technologies (ie, ultraviolet light [UVL] or hydrogen peroxide vapor [HPV] systems) can limit the transmission of nosocomial pathogens and prevent healthcare-associated infections (HAIs). To investigate these findings further, we performed a systematic literature review and meta-analysis on the impact of no-touch disinfection methods to decrease HAIs. METHODS: We searched PubMed, CINAHL, CDSR, DARE and EMBASE through April 2017 for studies evaluating no-touch disinfection technology and the nosocomial infection rates for Clostridium difficile, methicillin-resistant Staphylococcus aureus(MRSA), vancomycin-resistant enterococci (VRE), and other multidrug-resistant organisms (MDROs). We employed random-effect models to obtain pooled risk ratio (pRR) estimates. Heterogeneity was evaluated with I 2 estimation and the Cochran Q statistic. Pooled risk ratios for C. difficile, MRSA, VRE, and MDRO were assessed separately. RESULTS: In total, 20 studies were included in the final review: 13 studies using UVL systems and 7 studies using HPV systems. When the results of the UVL studies were pooled, statistically significant reduction ins C. difficile infection (CDI) (pRR, 0.64; 95% confidence interval [CI], 0.49–0.84) and VRE infection rates (pRR, 0.42; 95% CI, 0.28–0.65) were observed. No differences were found in rates of MRSA or gram-negative multidrug-resistant pathogens. CONCLUSIONS: Ultraviolet light no-touch disinfection technology may be effective in preventing CDI and VRE infection. Infect Control Hosp Epidemiol 2018;39:20–31
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multistate point-prevalence survey of health care-associated infections
Magill, S. S., Edwards, J. R., Bamberg, W., Beldavs, Z. G., Dumyati, G., Kainer, M. A., Lynfield, R., Maloney, M., McAllister-Hollod, L., Nadle, J., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1306801 · Cited by 3,931
Cosgrove, S. E. (2006) · Clinical Infectious Diseases · doi:10.1086/499406 · Cited by 1,271 · cited 1×
“difficile and VRE cases are nonreimbursable and cost $14,000 per case on average.(35,46,47) We believe that no-touch methods (UVL and HPV systems) augment traditional cleaning but cannot replace it.”
Background
Cited by
Effectiveness of 222-nm ultraviolet light on disinfecting SARS-CoV-2 surface contamination
Kitagawa, H., Nomura, T., Nazmul, T., Omori, K., Shigemoto, N., Sakaguchi, T., & Ohge, H. (2021) · American Journal of Infection Control · doi:10.1016/j.ajic.2020.08.022 · Cited by 296
Casini, B., Tuvo, B., Cristina, M. L., Spagnolo, A. M., Totaro, M., Baggiani, A., & Privitera, G. P. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16193572 · Cited by 185
“Their high turnover, incorrect disinfectant contact times, and over-dilution of disinfectant solutions are negative factors for successful cleaning [32].”
BackgroundSartelli, M., Di Bella, S., McFarland, L. V., Khanna, S., Furuya-Kanamori, L., Abuzeid, N., Abu-Zidan, F. M., Ansaloni, L., Augustin, G., Bala, M., et al. (2019) · World Journal of Emergency Surgery · doi:10.1186/s13017-019-0228-3 · Cited by 159
Nurses’ View towards the Use of Robotic during Pandemic COVID-19 in Indonesia: A Qualitative Study
Taryudi, T., Lindayani, L., Purnama, H., & Mutiar, A. (2022) · Open Access Macedonian Journal of Medical Sciences · doi:10.3889/oamjms.2022.7645 · Cited by 18
“As a result, efforts to deploy robotics for COVID-19 must be focused on improving and gaining higher equipment and increasing safety [22], [23].”
Background
Metadata
- Authors
- Marra, A. R., Schweizer, M. L., & Edmond, M. B.
- Venue
- Infection Control & Hospital Epidemiology
- Publisher
- Cambridge University Press (CUP)
- Published
- 2017-11-16
- Volume
- 39
- Issue
- 1
- Pages
- 20-31
- ISSN
- 0899-823X (ISSN-L)
- 1559-6834
- OpenAlex
- W2769116131
- Cited by
- 118
- References
- 2
- FWCI
- 2.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: No-Touch Disinfection Methods to Decrease Multidrug-Resistant Organism Infections: A Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1017/ice.2017.226
- The paper
- Marra, A. R., Schweizer, M. L., & Edmond, M. B. (2018). No-Touch Disinfection Methods to Decrease Multidrug-Resistant Organism Infections: A Systematic Review and Meta-analysis. Infection Control & Hospital Epidemiology. https://doi.org/10.1017/ice.2017.226
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.