Rapid Quantification of Bone Collagen Content by ATR-FTIR Spectroscopy
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Expensive and time-consuming preparation procedures for radiocarbon and stable isotope analyses can be conducted on archaeological bone samples even if no collagen is preserved. Such unsuccessful preparation can lead to the partial destruction of valuable archaeological material. Establishing a rapid prescreening method for evaluating the amount of bone collagen while minimizing the impact of sampling constitutes a challenge for the preservation of archaeological collections. This study proposes and discusses a new methodology to detect and quantify collagen content in archaeological bone samples by attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. A total of 42 Pleistocene to modern bone samples were selected according to their nitrogen content measured using an elemental analyzer. Comparison of collagen content estimation using ATR-FTIR and mass spectrometry reveals that some of the studied samples are contaminated by a nitrogen source coming from the burial environment. Two different FTIR calibration approaches were tested on the uncontaminated samples: peak-to-peak ratio and multivariate regression (PLS). The two approaches yield similar results with a good correlation of ATR-FTIR analyses and N wt% from 0.7 to 4wt% (R ²=0.97–0.99; standard error of estimation ±0.22 to 0.25wt%). While collagen content remains difficult to detect in poorly preserved bones (less than ~3wt%), ATR-FTIR analysis can be a fast alternative for sample screening to optimize the sampling strategy and avoid partial destruction of valuable samples that do not contain enough collagen for further analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The survival of organic matter in bone: a review
Collins, M. J., Nielsen–Marsh, C. M., Hiller, J., Smith, C. I., Roberts, J. P., Prigodich, R. V., Wess, T. J., Csapò, J., Millard, A. R., & Turner–Walker, G. (2002) · Archaeometry · doi:10.1111/1475-4754.t01-1-00071 · Cited by 615 · cited 2×
“…(3) Then, considering that a modern bone contain around 22wt% of collagen and consequently 4wt% of nitrogen (Stafford et al. 1988; van Klinken 1999; Collins et al. 2002), the wt% of collagen remaining in archaeological bone can be calculated by ATR-FTIR using Equation 4 with a standard error of…”
MethodYizhaq, M., Mintz, G., Cohen, I., Khalaily, H., Weiner, S., & Boaretto, E. (2005) · Radiocarbon · doi:10.1017/s003382220001969x · Cited by 129 · cited 2×
“No traces of nitrates and ammonium were identified on archaeological samples spectra as well as before or after NaOH treatment (main absorption peaks around, respectively, 1380 and 1430 cm–1; Busigny et al. 2003; Yizhaq et al. 2005).”
BackgroundMethod
Cited by
Pothier Bouchard, G., Mentzer, S. M., Riel-Salvatore, J., Hodgkins, J., Miller, C. E., Negrino, F., Wogelius, R., & Buckley, M. (2019) · Journal of Archaeological Science: Reports · doi:10.1016/j.jasrep.2019.05.027 · Cited by 18
Macroscopic electrostatic effects in ATR-FTIR spectra of modern and archeological bones
Aufort, J., Lebon, M., Gallet, X., Ségalen, L., Gervais, C., Brouder, C., & Balan, E. (2018) · American Mineralogist · doi:10.2138/am-2018-6320ccbyncnd · Cited by 16
“Three archaeological animal bone and a modern ox bone samples (Table 1), previously investigated using ATR-FTIR spectroscopy by Lebon et al. (2016), were chosen for their various states of collagen preservation as well as a modern tooth enamel sample previously investigated by Yi et al. (2014).”
BackgroundMethodInfluentialSelf-citationBurguet-Coca, A., Del Valle, H., Expósito, I., Herrejón-Lagunilla, Á., Buitkute, E., Cabanes, D., Cáceres, I., Carrancho, Á., & Villalaín, J. J. (2022) · Interdisciplinary Contributions to Archaeology · doi:10.1007/978-3-031-12278-1_5 · Cited by 7
Taphonomy and diagenesis of submerged bone: An experimental approach
Guareschi, E. E., Nicholls, P. K., Tobe, S. S., & Magni, P. A. (2025) · Forensic Science International · doi:10.1016/j.forsciint.2025.112416 · Cited by 6
Metadata
- Authors
- Lebon, M., Reiche, I., Gallet, X., Bellot-Gurlet, L., & Zazzo, A.
- Venue
- Radiocarbon
- Publisher
- Cambridge University Press (CUP)
- Published
- 2016-01-05
- Volume
- 58
- Issue
- 1
- Pages
- 131-145
- ISSN
- 0033-8222 (ISSN-L)
- 1945-5755
- OpenAlex
- W2225662731
- Cited by
- 137
- References
- 2
- FWCI
- 8.84
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid Quantification of Bone Collagen Content by ATR-FTIR Spectroscopy. https://app.cochat.ai/papers/10.1017/rdc.2015.11
- The paper
- Lebon, M., Reiche, I., Gallet, X., Bellot-Gurlet, L., & Zazzo, A. (2016). Rapid Quantification of Bone Collagen Content by ATR-FTIR Spectroscopy. Radiocarbon. https://doi.org/10.1017/rdc.2015.11
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.