CoChat

Testing the Effectiveness of Protocols for Removal of Common Conservation Treatments for Radiocarbon Dating

Open access
Brock, Fiona, Dee, Michael, Hughes, Andrew, Snoeck, Christophe, Staff, Richard, Bronk Ramsey, Christopher · 2018 · Radiocarbon
Cited by 62

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

To achieve a reliable radiocarbon (14 C) date for an object, any contamination that may be of a different age must be removed prior to dating. Samples that have been conserved with treatments such as adhesives, varnishes or consolidants can pose a particular challenge to 14 C dating. At the Oxford Radiocarbon Accelerator Unit (ORAU), common examples of such substances encountered include shellac, the acrylic polymers Paraloid B-67 and B-72, and vinyl acetate-derived polymers (e.g. PVA). Here, a non-carbon-containing absorbent substrate called Chromosorb®was deliberately contaminated with a range of varieties or brands of these conservation treatments, as well as two cellulose nitrate lacquers. A selection of chemical pretreatments was tested for their efficiency at removing them. While the varieties of shellac and Paraloid tested were completely removed with some treatments (water/methanol and acetone/methanol/chloroform sequential washes, respectively), no method was found that was capable of completely removing any of the vinyl acetate-derived materials or the cellulose nitrate lacquers. While Chromosorb is not an exact analog of archaeological wood or bone, for example, this study suggests that it may be possible to remove aged shellac and Paraloid from archaeological specimens with standard organic solvent-acid-base-acid pretreatments, but it may be significantly more difficult to remove vinyl acetate-derived polymers and cellulose nitrate lacquers sufficiently to provide reliable 14 C dates. The four categories of conservation treatment studied demonstrate characteristic FTIR spectra, while highlighting subtle chemical and molecular differences between different varieties of shellac, Paraloid and cellulose nitrate lacquers, and significant differences between the vinyl acetate derivatives.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/rdc.2017.68

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Brock, F., Dee, M., Hughes, A., Snoeck, C., Staff, R., & Bronk Ramsey, C.
Venue
Radiocarbon
Published
2017-08-09
Volume
60
Issue
1
Pages
35-50
ISSN
  • 0033-8222 (ISSN-L)
  • 1945-5755
OpenAlex
W2743660118
Cited by
62
References
1
FWCI
3.71
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.