CoChat

UK Food Standards Agency Workshop Consensus Report: the choice of method for measuring 25-hydroxyvitamin D to estimate vitamin D status for the UK National Diet and Nutrition Survey

Open access
Hunty, Anne de la, Wallace, A. Michael, Gibson, Sigrid, Viljakainen, Heli, Lamberg-Allardt, Christel, Ashwell, Margaret · 2010 · British Journal of Nutrition
Cited by 121

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The consensus workshop, organised on behalf of the Food Standards Agency, was convened to recommend the most appropriate and secure method for measuring vitamin D status in the UK. Workshop participants (the Expert Panel) were invited on the basis of expertise in current 25-hydroxyvitamin D (25OHD) assays, or expertise in vitamin D nutrition and metabolism or detailed knowledge and experience in the National Diet and Nutrition Survey (NDNS). A decision support matrix, which set out the particular criteria by which the different options were scored and evaluated, was used to structure the discussion. The Expert Panel agreed that five methods for measuring 25OHD should be evaluated according to eleven criteria, selected on the basis of their relevance to the NDNS. All three of the evaluating subgroups of the Expert Panel produced similar total scores over the eleven criteria for the different methods; they scored LC–MS/MS and HPLC-UV similarly highly, while the scores for the immunoassay methods were lower. The Expert Panel recommended that an LC–MS/MS method should be the preferred method for the NDNS. A detailed specification for the method will be required to ensure comparability between NDNS and the National Health and Nutrition Examination Survey in the US facilitating future comparisons. The Expert Panel also recommended that the method should be carried out in a laboratory with appropriate expertise, competency and history of records of good performance. The method should be standardised against the National Institute of Standards and Technology SRM 972. If the recommended LC–MS/MS is adopted, the Expert Panel indicated that the method should be able to discriminate the C-3 epimer of 25OHD 3, especially if used to measure 25OHD in young infants in the forthcoming Diet and Nutrition Survey of Infants and Young Children, who are known to have high circulating concentrations of the C-3 epimer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s000711451000214x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 121

Metadata

Authors
Hunty, A. D. L., Wallace, A. M., Gibson, S., Viljakainen, H., Lamberg-Allardt, C., & Ashwell, M.
Venue
British Journal of Nutrition
Published
2010-08-16
Volume
104
Issue
4
Pages
612-619
ISSN
  • 0007-1145 (ISSN-L)
  • 1475-2662
OpenAlex
W2111866577
Cited by
121
References
1
FWCI
8.27
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: UK Food Standards Agency Workshop Consensus Report: the choice of method for measuring 25-hydroxyvitamin D to estimate vitamin D status for the UK National Diet and Nutrition Survey. https://app.cochat.ai/papers/10.1017/s000711451000214x
The paper
Hunty, A. D. L., Wallace, A. M., Gibson, S., Viljakainen, H., Lamberg-Allardt, C., & Ashwell, M. (2010). UK Food Standards Agency Workshop Consensus Report: the choice of method for measuring 25-hydroxyvitamin D to estimate vitamin D status for the UK National Diet and Nutrition Survey. British Journal of Nutrition. https://doi.org/10.1017/s000711451000214x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.