UK Food Standards Agency Workshop Consensus Report: the choice of method for measuring 25-hydroxyvitamin D to estimate vitamin D status for the UK National Diet and Nutrition Survey
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The consensus workshop, organised on behalf of the Food Standards Agency, was convened to recommend the most appropriate and secure method for measuring vitamin D status in the UK. Workshop participants (the Expert Panel) were invited on the basis of expertise in current 25-hydroxyvitamin D (25OHD) assays, or expertise in vitamin D nutrition and metabolism or detailed knowledge and experience in the National Diet and Nutrition Survey (NDNS). A decision support matrix, which set out the particular criteria by which the different options were scored and evaluated, was used to structure the discussion. The Expert Panel agreed that five methods for measuring 25OHD should be evaluated according to eleven criteria, selected on the basis of their relevance to the NDNS. All three of the evaluating subgroups of the Expert Panel produced similar total scores over the eleven criteria for the different methods; they scored LC–MS/MS and HPLC-UV similarly highly, while the scores for the immunoassay methods were lower. The Expert Panel recommended that an LC–MS/MS method should be the preferred method for the NDNS. A detailed specification for the method will be required to ensure comparability between NDNS and the National Health and Nutrition Examination Survey in the US facilitating future comparisons. The Expert Panel also recommended that the method should be carried out in a laboratory with appropriate expertise, competency and history of records of good performance. The method should be standardised against the National Institute of Standards and Technology SRM 972. If the recommended LC–MS/MS is adopted, the Expert Panel indicated that the method should be able to discriminate the C-3 epimer of 25OHD 3, especially if used to measure 25OHD in young infants in the forthcoming Diet and Nutrition Survey of Infants and Young Children, who are known to have high circulating concentrations of the C-3 epimer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rosner, W., Auchus, R. J., Azziz, R., Sluss, P. M., & Raff, H. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-1864 · Cited by 1,176 · cited 1×
“In response to concerns about the validity of some testosterone assays, the Endocrine Society in the United States recently published a position statement, which concluded that direct immunoassays perform poorly at low testosterone concentrations and should be avoided (13) .”
Cited by
Lips, P., Cashman, K. D., Lamberg-Allardt, C., Bischoff-Ferrari, H. A., Obermayer-Pietsch, B., Bianchi, M. L., Stepan, J., El-Hajj Fuleihan, G., & Bouillon, R. (2019) · European Journal of Endocrinology · doi:10.1530/eje-18-0736 · Cited by 662
Self-citationSempos, C. T., Heijboer, A. C., Bikle, D. D., Bollerslev, J., Bouillon, R., Brannon, P. M., DeLuca, H. F., Jones, G., Munns, C. F., Bilezikian, J. P., et al. (2018) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.13652 · Cited by 331
An Update on Vitamin D Metabolism
Saponaro, F., Saba, A., & Zucchi, R. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21186573 · Cited by 308
Optimal Vitamin D Status: A Critical Analysis on the Basis of Evidence-Based Medicine
Bouillon, R., Van Schoor, N. M., Gielen, E., Boonen, S., Mathieu, C., Vanderschueren, D., & Lips, P. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-1195 · Cited by 274
Standardizing vitamin D assays: The way forward
Binkley, N., Sempos, C. T., & (VDSP), F. T. V. D. S. P. (2014) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2252 · Cited by 204
“Those advantages led to the recommendation by others that liquid chromatography with tandem mass spectrometry (LC‐MS/MS) assays be used in national surveys.((32)) However, it must be recognized that mass spectrometry assays require a costly investment and experienced laboratorians to operate them; if not set up and ru…”
Background
Metadata
- Authors
- Hunty, A. D. L., Wallace, A. M., Gibson, S., Viljakainen, H., Lamberg-Allardt, C., & Ashwell, M.
- Venue
- British Journal of Nutrition
- Publisher
- Cambridge University Press (CUP)
- Published
- 2010-08-16
- Volume
- 104
- Issue
- 4
- Pages
- 612-619
- ISSN
- 0007-1145 (ISSN-L)
- 1475-2662
- OpenAlex
- W2111866577
- Cited by
- 121
- References
- 1
- FWCI
- 8.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: UK Food Standards Agency Workshop Consensus Report: the choice of method for measuring 25-hydroxyvitamin D to estimate vitamin D status for the UK National Diet and Nutrition Survey. https://app.cochat.ai/papers/10.1017/s000711451000214x
- The paper
- Hunty, A. D. L., Wallace, A. M., Gibson, S., Viljakainen, H., Lamberg-Allardt, C., & Ashwell, M. (2010). UK Food Standards Agency Workshop Consensus Report: the choice of method for measuring 25-hydroxyvitamin D to estimate vitamin D status for the UK National Diet and Nutrition Survey. British Journal of Nutrition. https://doi.org/10.1017/s000711451000214x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.