Peristaltic pumping with long wavelengths at low Reynolds number
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Pumping by means of an infinite train of peristaltic waves is investigated under conditions for which the relevant Reynolds number is small enough for inertial effects to be negligible and the wavelength to diameter ratio is large enough for the pressure to be considered uniform over the cross-section. Theoretical results are presented for both plane and axisymmetric geometries, and for amplitude ratios ranging from zero to full occlusion. For a given amplitude ratio, the theoretical pressure rise per wavelength decreases linearly with increasing time-mean flow. An experiment with a quasi-two-dimensional apparatus confirmed the theoretical values. Calculations of the detailed fluid motions reveal that under many conditions of operation the net time-mean flow is the algebraic difference between a forward time-mean flow in the core of the tube and a backward (‘reflux’) time-mean flow near the periphery. The percentage of reflux flow can be very high. This reflux phenomenon is probably of physiologic significance in the functioning of the ureter and the gastro-intestinal system. A second fluid-mechanical peculiarity with physiological implications is that of ‘trapping’: under certain conditions an internally circulating bolus of fluid, lying about the axis, is transported with the wave speed as though it were trapped by the wave.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MAXIMOW, A. A., & BLOOM, W. (1930) · The American Journal of the Medical Sciences · doi:10.1097/00000441-193012000-00020 · Cited by 660
Boundary Layer Theory, Sixth Edition
Schlichting, H., & Shapiro, A. H. (1968) · Journal of Applied Mechanics · doi:10.1115/1.3601336 · Cited by 221
Self-citation
Cited by
Mechanisms to explain the reverse perivascular transport of solutes out of the brain
Schley, D., Carare-Nnadi, R., Please, C. P., Perry, V. H., & Weller, R. O. (2006) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2005.07.005 · Cited by 293
Analysis of Intra-uterine Fluid Motion Induced by Uterine Contractions
Eytan, O. (1999) · Bulletin of Mathematical Biology · doi:10.1006/bulm.1998.0069 · Cited by 248
Modelling the lymphatic system: challenges and opportunities
Margaris, K. N., & Black, R. A. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0751 · Cited by 229
Non-linear peristaltic flow of a fourth grade fluid in an inclined asymmetric channel
Haroun, M. H. (2007) · Computational Materials Science · doi:10.1016/j.commatsci.2006.06.012 · Cited by 178
Electroosmosis-modulated peristaltic transport in microfluidic channels
Bandopadhyay, A., Tripathi, D., & Chakraborty, S. (2016) · Physics of Fluids · doi:10.1063/1.4947115 · Cited by 176
Ebaid, A. (2008) · Physics Letters A · doi:10.1016/j.physleta.2008.04.031 · Cited by 159
Fluid dynamics of cerebrospinal fluid flow in perivascular spaces
Thomas, J. H. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0572 · Cited by 155
Metadata
- Authors
- Shapiro, A. H., Jaffrin, M. Y., & Weinberg, S. L.
- Venue
- Journal of Fluid Mechanics
- Publisher
- Cambridge University Press (CUP)
- Published
- 1969-07-28
- Volume
- 37
- Issue
- 4
- Pages
- 799-825
- ISSN
- 0022-1120 (ISSN-L)
- 1469-7645
- OpenAlex
- W1602803188
- Cited by
- 1,697
- References
- 2
- FWCI
- 10.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.