Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 302

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Convection in a compressible fluid with infinite Prandtl number

Jarvis, Gary T., Mckenzie, Dan P.·1980·Journal of Fluid Mechanics

Abstract

An approximate set of equations is derived for a compressible liquid of infinite Prandtl number. These are referred to as the anelastic-liquid equations. The approximation requires the product of absolute temperature and volume coefficient of thermal expansion to be small compared to one. A single parameter defined as the ratio of the depth of the convecting layer,d, to the temperature scale height of the liquid,HT, governs the importance of the non-Boussinesq effects of compressibility, viscous dissipation, variable adiabatic temperature gradients and non-hydrostatic pressure gradients. When d/HT[Lt ] 1 the Boussinesq equations result, but when d/HT is O(1) the non-Boussinesq terms become important. Using a time-dependent numerical model, the anelastic-liquid equations are solved in two dimensions and a systematic investigation of compressible convection is presented in which d/HT is varied from 0·1 to 1·5. Both marginal stability and finite-amplitude convection are studied. For d/HT[les ] 1·0 the effect of density variations is primarily geometric; descending parcels of liquid contract and ascending parcels expand, resulting in an increase in vorticity with depth. When d/HT> 1·0 the density stratification significantly stabilizes the lower regions of the marginal state solutions. At all values of d/HT[ges ] 0·25, an adiabatic temperature gradient proportional to temperature has a noticeable stabilizing effect on the lower regions. For d/HT[ges ] 0·5, marginal solutions are completely stabilized at the bottom of the layer and penetrative convection occurs for a finite range of supercritical Rayleigh numbers. In the finite-amplitude solutions adiabatic heating and cooling produces an isentropic central region. Viscous dissipation acts to redistribute buoyancy sources and intense frictional heating influences flow solutions locally in a time-dependent manner. The ratio of the total viscous heating in the convecting system, ϕ, to the heat flux across the upper surface,Fu, has an upper limit equal to d/HT. This limit is achieved at high Rayleigh numbers, when heating is entirely from below, and, for sufficiently large values of d/HT, Φ/Fuis greater than 1·00.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s002211208000225x

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 302

Metadata

Authors
Jarvis, G. T., & Mckenzie, D. P.
Venue
Journal of Fluid Mechanics
Published
1980-02-13
Volume
96
Issue
3
Pages
515-583
ISSN
  • 0022-1120 (ISSN-L)
  • 1469-7645
OpenAlex
W2115914348
Cited by
302
References
31
FWCI
7.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Convection in a compressible fluid with infinite Prandtl number. https://app.cochat.ai/papers/10.1017/s002211208000225x
The paper
Jarvis, G. T., & Mckenzie, D. P. (1980). Convection in a compressible fluid with infinite Prandtl number. Journal of Fluid Mechanics. https://doi.org/10.1017/s002211208000225x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.