CoChat

The Globe Thermometer in Studies of Heating and Ventilation

Open access
Bedford, T., Warner, C. G. · 1934 · Epidemiology and Infection
Cited by 127

The DOI matches its Crossref record.

Abstract

The effects of radiation and convection on the globe thermometer have been studied. Equations have been obtained, and alignment charts constructed, for the calculation of mean radiation intensity and of equivalent temperature from readings of the globe thermometer, air temperature and air velocity. The accuracy of these methods has been tested on observations made under industrial conditions. Taking direct thermopile observations as the standard, the mean radiation intensity values calculated from globe thermometer readings had an average error of 1·2 B.Th.U. per sq. ft. per hour. With eupatheoscope readings as standard, equivalent temperature estimates had a mean error of 1·2°. It is concluded that, while globe thermometer readings alone are unreliable as indications of the effects of the thermal environment, valuable results can be obtained by using the instrument along with an ordinary thermometer and a silvered kata-thermometer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s0022172400043242

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 127

Metadata

Authors
Bedford, T., & Warner, C. G.
Venue
Epidemiology and Infection
Published
1934-12
Volume
34
Issue
4
Pages
458-473
ISSN
  • 0950-2688 (ISSN-L)
  • 1469-4409
OpenAlex
W2127964622
Cited by
127
References
0
FWCI
0.00
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Globe Thermometer in Studies of Heating and Ventilation. https://app.cochat.ai/papers/10.1017/s0022172400043242
The paper
Bedford, T., & Warner, C. G. (1934). The Globe Thermometer in Studies of Heating and Ventilation. Epidemiology and Infection. https://doi.org/10.1017/s0022172400043242

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.