Single particle electron cryomicroscopy: trends, issues and future perspective
Open accessThe DOI matches its Crossref record; 106 of the 106 references it cites were found in a registry or an index.
Abstract
There has been enormous progress during the last few years in the determination of three-dimensional biological structures by single particle electron cryomicroscopy (cryoEM), allowing maps to be obtained with higher resolution and from fewer images than required previously. This is due principally to the introduction of a new type of direct electron detector that has 2- to 3-fold higher detective quantum efficiency than available previously, and to the improvement of the computational algorithms for image processing. In spite of the great strides that have been made, quantitative analysis shows that there are still significant gains to be made provided that the problems associated with image degradation can be solved, possibly by minimising beam-induced specimen movement and charge build up during imaging. If this can be achieved, it should be possible to obtain near atomic resolution structures of smaller single particles, using fewer images and resolving more conformational states than at present, thus realising the full potential of the method. The recent popularity of cryoEM for molecular structure determination also highlights the need for lower cost microscopes, so we encourage development of an inexpensive, 100 keV electron cryomicroscope with a high-brightness field emission gun to make the method accessible to individual groups or institutions that cannot afford the investment and running costs of a state-of-the-art 300 keV installation. A key requisite for successful high-resolution structure determination by cryoEM includes interpretation of images and optimising the biochemistry and grid preparation to obtain nicely distributed macromolecules of interest. We thus include in this review a gallery of cryoEM micrographs that shows illustrative examples of single particle images of large and small macromolecular complexes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RELION: Implementation of a Bayesian approach to cryo-EM structure determination
Scheres, S. H. W. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.09.006 · Cited by 5,446 · cited 3×
“Later work with 3D classification in RELION on the same dataset of images, showed the additional presence of about 10% of particles that contained only the large subunit (Scheres, 2012).”
MethodEMAN2: An extensible image processing suite for electron microscopy
Tang, G., Peng, L., Baldwin, P. R., Mann, D. S., Jiang, W., Rees, I., & Ludtke, S. J. (2007) · Journal of Structural Biology · doi:10.1016/j.jsb.2006.05.009 · Cited by 2,994 · cited 2×
“EMAN (Ludtke et al. 1999; Tang et al. 2007) and Frealign (Grigorieff, 1998, 2007) were developed later with explicit treatment of the CTF that would be required to reach high resolution.”
BackgroundMethodModel for the structure of bacteriorhodopsin based on high-resolution electron cryo-microscopy
Henderson, R., Baldwin, J. M., Ceska, T. A., Zemlin, F., Beckmann, E., & Downing, K. H. (1990) · Journal of Molecular Biology · doi:10.1016/s0022-2836(05)80271-2 · Cited by 2,980 · cited 2×
“A 3D structure of bacteriorhodopsin at 3.5 Å was obtained by averaging images containing 5 million molecules recorded using film as the detector (Henderson et al. 1990).”
MethodInfluentialSelf-citationRosenthal, P. B., & Henderson, R. (2003) · Journal of Molecular Biology · doi:10.1016/j.jmb.2003.07.013 · Cited by 2,416 · cited 1×
“Later Rosenthal & Henderson (2003) argued that, since the X-ray protein crystallography community had agreed upon a figure-of-merit of 0.5 as a threshold criterion of structure factor quality, equivalent to a phase error of 60°, the EM community should adopt the same criterion, which Fig.”
BackgroundInfluentialSelf-citationEMAN: Semiautomated Software for High-Resolution Single-Particle Reconstructions
Ludtke, S. J., Baldwin, P. R., & Chiu, W. (1999) · Journal of Structural Biology · doi:10.1006/jsbi.1999.4174 · Cited by 2,391 · cited 5×
“EMAN had a similar GUI from the beginning, which makes these two systems very popular.”
BackgroundMethodInfluentialCryo-electron microscopy of vitrified specimens
Dubochet, J., Adrian, M., Chang, J.-J., Homo, J.-C., Lepault, J., McDowall, A. W., & Schultz, P. (1988) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500004297 · Cited by 2,389 · cited 2×
“Dubochet et al. (1988) showed that beautiful images of a whole series of structures from ferritin to adenovirus could be recorded after rapidly freezing EM grids on which thin suspensions of the structures in normal aqueous buffer had been made by application of a small drop followed by blotting…”
BackgroundMethodInfluentialThree-dimensional model of purple membrane obtained by electron microscopy
Henderson, R., & Unwin, P. N. T. (1975) · Nature · doi:10.1038/257028a0 · Cited by 2,282 · cited 1×
“Unwin & Henderson determined the 3D structure of bacteriorhodopsin to 7 Å resolution by averaging data from images of unstained 2D crystals of bacteriorhodopsin (purple membrane) at room temperature (Unwin & Henderson, 1975; Henderson & Unwin, 1975).”
BackgroundSelf-citationStructure of the αβ tubulin dimer by electron crystallography
Nogales, E., Wolf, S. G., & Downing, K. H. (1998) · Nature · doi:10.1038/34465 · Cited by 2,076 · cited 1×
“Similar numbers were needed to determine the structure for 2D crystals of light-harvesting complex (LHC) II (Kuhlbrandt et al. 1994) and αβ-tubulin zinc sheets (Nogales et al. 1998).”
BackgroundAtomic model of plant light-harvesting complex by electron crystallography
Kühlbrandt, W., Wang, D. N., & Fujiyoshi, Y. (1994) · Nature · doi:10.1038/367614a0 · Cited by 1,905 · cited 1×
“Similar numbers were needed to determine the structure for 2D crystals of light-harvesting complex (LHC) II (Kuhlbrandt et al. 1994) and αβ-tubulin zinc sheets (Nogales et al. 1998).”
BackgroundLi, X., Mooney, P., Zheng, S., Booth, C. R., Braunfeld, M. B., Gubbens, S., Agard, D. A., & Cheng, Y. (2013) · Nature Methods · doi:10.1038/nmeth.2472 · Cited by 1,818
Cited by
Unravelling biological macromolecules with cryo-electron microscopy
Fernandez-Leiro, R., & Scheres, S. H. W. (2016) · Nature · doi:10.1038/nature19948 · Cited by 413
Impact of GPCR Structures on Drug Discovery
Congreve, M., de Graaf, C., Swain, N. A., & Tate, C. G. (2020) · Cell · doi:10.1016/j.cell.2020.03.003 · Cited by 375
Challenges and opportunities in cryo-EM single-particle analysis
Lyumkis, D. (2019) · Journal of Biological Chemistry · doi:10.1074/jbc.rev118.005602 · Cited by 356
Protein Design: From the Aspect of Water Solubility and Stability
Qing, R., Hao, S., Smorodina, E., Jin, D., Zalevsky, A., & Zhang, S. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00757 · Cited by 312
Cryo-EM structure of the adenosine A2A receptor coupled to an engineered heterotrimeric G protein
García-Nafría, J., Lee, Y., Bai, X., Carpenter, B., & Tate, C. G. (2018) · eLife · doi:10.7554/elife.35946 · Cited by 253
Protein assemblies ejected directly from native membranes yield complexes for mass spectrometry
Chorev, D. S., Baker, L. A., Wu, D., Beilsten-Edmands, V., Rouse, S. L., Zeev-Ben-Mordehai, T., Jiko, C., Samsudin, F., Gerle, C., Khalid, S., et al. (2018) · Science · doi:10.1126/science.aau0976 · Cited by 191
Better, Faster, Cheaper: Recent Advances in Cryo–Electron Microscopy
Chua, E. Y. D., Mendez, J. H., Rapp, M., Ilca, S. L., Tan, Y. Z., Maruthi, K., Kuang, H., Zimanyi, C. M., Cheng, A., Eng, E. T., et al. (2022) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-032620-110705 · Cited by 159
Targeting GPCRs and Their Signaling as a Therapeutic Option in Melanoma
Raymond, J. H., Aktary, Z., Larue, L., & Delmas, V. (2022) · Cancers · doi:10.3390/cancers14030706 · Cited by 20
Factors affecting macromolecule orientations in thin films formed in cryo-EM
Yadav, S., & Vinothkumar, K. R. (2024) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798324005229 · Cited by 7
Self-citationFactors affecting macromolecule orientations in thin films formed in cryo-EM
(2023) · doi:10.1101/2023.11.06.565913 · Cited by 7
Metadata
- Authors
- Vinothkumar, K. R., & Henderson, R.
- Venue
- Quarterly Reviews of Biophysics
- Publisher
- Cambridge University Press (CUP)
- Published
- 2016
- Volume
- 49
- Pages
- e13-e13
- ISSN
- 0033-5835 (ISSN-L)
- 1469-8994
- OpenAlex
- W2498179566
- Cited by
- 206
- References
- 106
- FWCI
- 1.99
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.