AMS 14C Sample Preparation at the KCCAMS/UCI Facility: Status Report and Performance of Small Samples
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We present an overview of accelerator mass spectrometry (AMS) radiocarbon sample preparation and measurements, describing the technical upgrades that now allow us to routinely obtain 0.2–0.3% precision for 1-mg carbon samples. A precision of ∼1% on samples with 100 μg of carbon can also be achieved. We have also developed graphitization techniques and AMS procedures for ultra-small samples (down to 0.002 mg of carbon). Detailed time series are presented for large and small aliquots of standards such as NIST OX-I and OX-II; FIRI-C and -D; IAEA-C6, -C7 and -C8; and 14 C-free samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Southon, J., Santos, G., Druffel-Rodriguez, K., Druffel, E., Trumbore, S., Xu, X., Griffin, S., Ali, S., & Mazon, M. (2004) · Radiocarbon · doi:10.1017/s0033822200039333 · Cited by 142 · cited 2×
“…of 2003 in the number of times the Mg(ClO4)2 was reused before it was discarded (Santos et al. 2004), plus several improvements to the ion-source initiated in December of 2003 (Southon and Santos 2004a,b, 2007; Southon et al. 2005) contributed to the improvement in precision (Figures 1 and 2).”
BackgroundMethodSelf-citation
Cited by
Kramer, C., Trumbore, S., Fröberg, M., Cisneros Dozal, L. M., Zhang, D., Xu, X., Santos, G. M., & Hanson, P. J. (2010) · Soil Biology and Biochemistry · doi:10.1016/j.soilbio.2010.02.021 · Cited by 138
“The correction we apply is size dependent and based on Santos et al. (2007), since a constant addition of microgram quantities of C will be a large proportion of the total for very small (several microgram) samples.”
BackgroundMethodInfluentialSelf-citationBlank Assessment for Ultra-Small Radiocarbon Samples: Chemical Extraction and Separation Versus AMS
Santos, G. M., Southon, J. R., Drenzek, N. J., Ziolkowski, L. A., Druffel, E., Xu, X., Zhang, D., Trumbore, S., Eglinton, T. I., & Hughen, K. A. (2010) · Radiocarbon · doi:10.1017/s0033822200046415 · Cited by 103
Self-citationThe Phytolith14C Puzzle: A Tale of Background Determinations and Accuracy Tests
Santos, G. M., Alexandre, A., Coe, H. H. G., Reyerson, P. E., Southon, J. R., & De Carvalho, C. N. (2010) · Radiocarbon · doi:10.1017/s0033822200045070 · Cited by 71
“These corrections are about 10 times higher than the corrections necessary for our 14C AMS target preparation alone (Santos et al. 2007a,b).”
BackgroundMethodSelf-citationNoronha, A. L., Johnson, K. R., Southon, J. R., Hu, C., Ruan, J., & McCabe-Glynn, S. (2015) · Quaternary Science Reviews · doi:10.1016/j.quascirev.2015.05.021 · Cited by 57
“After conversion to CO2, calcite samples were converted to graphite via iron catalyzed hydrogen reduction following standard protocols as described in Santos et al. (2007).”
MethodSelf-citationSeifert, A.-G., Trumbore, S., Xu, X., Zhang, D., Kothe, E., & Gleixner, G. (2011) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2011.02.037 · Cited by 34
Self-citation
Metadata
- Authors
- Santos, G. M., Moore, R. B., Southon, J. R., Griffin, S., Hinger, E., & Zhang, D.
- Venue
- Radiocarbon
- Publisher
- Cambridge University Press (CUP)
- Published
- 2007
- Volume
- 49
- Issue
- 2
- Pages
- 255-269
- ISSN
- 0033-8222 (ISSN-L)
- 1945-5755
- OpenAlex
- W1929920236
- Cited by
- 136
- References
- 1
- FWCI
- 4.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: AMS 14C Sample Preparation at the KCCAMS/UCI Facility: Status Report and Performance of Small Samples. https://app.cochat.ai/papers/10.1017/s0033822200042181
- The paper
- Santos, G. M., Moore, R. B., Southon, J. R., Griffin, S., Hinger, E., & Zhang, D. (2007). AMS 14C Sample Preparation at the KCCAMS/UCI Facility: Status Report and Performance of Small Samples. Radiocarbon. https://doi.org/10.1017/s0033822200042181
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.