Objectives and technological approach to the development of the multifunctional MANUS upper limb prosthesis
The DOI matches its Crossref record.
Abstract
The design of multifunctional upper limb prosthetics has been investigated in recent years. In 1998, the MANUS consortium was set up on the basis of multidisciplinary skills of the partners in order to provide a global approach to the problem of upper limb prosthetics. In the framework of this approach, the consortium addressed the development of appropriate hand mechanics, the analysis and implementation of control electronics, the development of advanced control strategies and the implementation of broad band command interfaces based on EMG. As a result, the prototype of a multifunctional prosthesis was developed, integrated and clinically evaluated. This paper describes the objectives, technological approach and results of the MANUS prosthesis prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Upper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111
Consumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519
“More recently, Pons et al. (2005) [14], reported on the concerns of individuals with traumatic limb loss specifically.”
BackgroundSensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Myoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
The SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-29 · Cited by 286
Metadata
- Authors
- Pons, J. L., Ceres, R., Rocon, E., Reynaerts, D., Saro, B., Levin, S., & Van Moorleghem, W.
- Venue
- Robotica
- Publisher
- Cambridge University Press (CUP)
- Published
- 2005-04-27
- Volume
- 23
- Issue
- 3
- Pages
- 301-310
- ISSN
- 0263-5747 (ISSN-L)
- 1469-8668
- OpenAlex
- W1992883811
- Cited by
- 33
- References
- 0
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Objectives and technological approach to the development of the multifunctional MANUS upper limb prosthesis. https://app.cochat.ai/papers/10.1017/s0263574704001328
- The paper
- Pons, J. L., Ceres, R., Rocon, E., Reynaerts, D., Saro, B., Levin, S., & Van Moorleghem, W. (2005). Objectives and technological approach to the development of the multifunctional MANUS upper limb prosthesis. Robotica. https://doi.org/10.1017/s0263574704001328
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.