Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 211

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Transcatheter closure as standard treatment for most interatrial defects: experience in 200 patients treated with the Amplatzer ™ Septal Occluder

Berger, Felix, Ewert, Peter, Boöjrnstad, Per G., Dähnert, Ingo, Krings, Gregor, Brilla-Austenat, Ira, Vogel, Michael, Lange, Peter E. · 1999 · Cardiology in the Young

Abstract

To judge whether an Amplatzer™ Septal Occluder can be used as standard therapy instead of surgery for closure of atrial septal defects we report our experiences in 200 patients. Of these patients, 127 had an atrial septal defect with haemodynamically significant left-to-right shunt, 68 patients a persistent oval foramen after presumed paradoxical embolism, and 5 had a fenestration after Fontan-repair. Mean age was 29.8 years (0.8 to 77.7 years). Body weight ranged from 6.9 to 120.0 kg (mean 51.5 kg). After diagnostic cardiac catheterization, and balloon-sizing of the defect, we implanted Amplatzer™ Septal Occluders with stents of 4 to 28 mm diameter. Follow-up studies were obtained after 48hours, and one, six, and twelve months. Transcatheter closure of the atrial septal defect proved successful in all without any relevant residual shunts. In particular, complete closure was achieved in all patients after presumed paradoxical embolism. The mean period of follow-up is 9–5 months, with a range from 0.4 to 23.5 months, giving a total of 1898 patient months. The occlusion rate after three month was 98.1°. A trivial haemodynamically insignificant residual shunt remained in 1.9° of the patients. Fluoroscopy times ranged from 0 to 43.5 minutes, with a median of 8.7 minutes. The excellent results in the short and medium term in children and adults have resulted in using this device routinely at the present time for closure of central atrial septal defects up to a diameter of 28 mm. Final judgement, however, is only possible after long-term follow-up.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s1047951100005369

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 211

Metadata

Authors
Berger, F., Ewert, P., Boöjrnstad, P. G., Dähnert, I., Krings, G., Brilla-Austenat, I., Vogel, M., & Lange, P. E.
Venue
Cardiology in the Young
Published
1999-09
Volume
9
Issue
5
Pages
468-473
ISSN
  • 1047-9511 (ISSN-L)
  • 1467-1107
OpenAlex
W2141217644
Cited by
211
References
2
FWCI
14.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcatheter closure as standard treatment for most interatrial defects: experience in 200 patients treated with the Amplatzer ™ Septal Occluder. https://app.cochat.ai/papers/10.1017/s1047951100005369
The paper
Berger, F., Ewert, P., Boöjrnstad, P. G., Dähnert, I., Krings, G., Brilla-Austenat, I., Vogel, M., & Lange, P. E. (1999). Transcatheter closure as standard treatment for most interatrial defects: experience in 200 patients treated with the Amplatzer ™ Septal Occluder. Cardiology in the Young. https://doi.org/10.1017/s1047951100005369

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.