CoChat

Bicuspid aortic valve outcomes

Open access
Rodrigues, Inês, Agapito, Ana F., de Sousa, Lídia, Oliveira, José A., Branco, Luísa M., Galrinho, Ana, Abreu, João, Timóteo, Ana T., Rosa, Sílvia A., Ferreira, Rui C. · 2017 · Cardiology in the Young
Cited by 47

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background: Bicuspid aortic valve is the most common CHD. Its association with early valvular dysfunction, endocarditis, thoracic aorta dilatation, and aortic dissection is well established. Objective: The aim of this study was to assess the incidence and predictors of cardiac events in adults with bicuspid aortic valve. Methods: We carried out a retrospective analysis of cardiac outcomes in ambulatory adults with bicuspid aortic valve followed-up in a tertiary hospital centre. Outcomes were defined as follows: interventional – intervention on the aortic valve or thoracic aorta; medical – death, aortic dissection, aortic valve endocarditis, congestive heart failure, arrhythmias, or ischaemic heart disease requiring hospital admission; and a composite end point of both. Kaplan–Meier curves were generated to determine event rates, and predictors of cardiac events were determined by multivariate analysis. Results: A total of 227 patients were followed-up over 13±9 years; 29% of patients developed severe aortic valve dysfunction and 12.3% reached ascending thoracic aorta dimensions above 45 mm. At least one cardiac outcome occurred in 38.8% of patients, with an incidence rate at 20 years of follow-up of 47±4%; 33% of patients were submitted to an aortic valve or thoracic aorta intervention. Survival 20 years after diagnosis was 94±2%. Independent predictors of the composite end point were baseline moderate–severe aortic valve dysfunction (hazard ratio, 3.19; 95% confidence interval, 1.35–7.54; p<0.01) and aortic valve leaflets calcification (hazard ratio, 4.72; 95% confidence interval, 1.91–11.64; p<0.005). Conclusions: In this study of bicuspid aortic valve, the long-term survival was excellent but with occurrence of frequent cardiovascular events. Baseline aortic valve calcification and dysfunction were the only independent predictors of events.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s1047951116002560

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 47

Metadata

Authors
Rodrigues, I., Agapito, A. F., de Sousa, L., Oliveira, J. A., Branco, L. M., Galrinho, A., Abreu, J., Timóteo, A. T., Rosa, S. A., & Ferreira, R. C.
Venue
Cardiology in the Young
Published
2016-12-12
Volume
27
Issue
3
Pages
518-529
ISSN
  • 1047-9511 (ISSN-L)
  • 1467-1107
OpenAlex
W2565728807
Cited by
47
References
4
FWCI
2.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bicuspid aortic valve outcomes. https://app.cochat.ai/papers/10.1017/s1047951116002560
The paper
Rodrigues, I., Agapito, A. F., de Sousa, L., Oliveira, J. A., Branco, L. M., Galrinho, A., Abreu, J., Timóteo, A. T., Rosa, S. A., & Ferreira, R. C. (2017). Bicuspid aortic valve outcomes. Cardiology in the Young. https://doi.org/10.1017/s1047951116002560

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.