The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index; 31 of the 50 sources its claims cite were checked for support.
Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis
Open accessAbstract
Background and Objectives: Difficult venous access (DVA) affects 10–26% of hospitalized patients and up to 60% in high-risk populations, leading to increased patient discomfort, delayed diagnosis, and substantial healthcare costs estimated at $4.7 billion annually in the United States. This meta-analysis aimed to systematically evaluate the effectiveness, safety, and implementation considerations of traditional and emerging strategies for obtaining blood samples in patients with DVA. Materials and Methods: We conducted a comprehensive systematic review and meta-analysis following PRISMA guidelines. We searched MEDLINE, Embase, CINAHL, and Cochrane databases from January 2016 to December 2023. Inclusion criteria encompassed randomized controlled trials, systematic reviews, and observational studies examining DVA interventions in adult and pediatric populations. Primary outcomes included first-attempt success rates, overall success rates, and complication rates. Statistical analysis used random-effects models with risk ratios and 95% confidence intervals. Results: Forty-seven studies involving 12,847 patients met the inclusion criteria. Technology-assisted approaches demonstrated superior outcomes compared to traditional techniques. Ultrasound guidance showed the highest effectiveness with a first-attempt success increase of 42% (RR 1.42, 95% CI 1.26–1.58, p < 0.001), followed by near-infrared visualization with a 28% increase (RR 1.28, 95% CI 1.14–1.42, p < 0.001). Population-specific approaches yielded significant benefits, including the use of scalp veins for infants and external jugular approaches for extreme DVA cases. Cost-effectiveness analysis revealed that ultrasound guidance achieved break-even within 8–14 months in high-volume centers. Conclusions: A systematic, stepwise approach integrating appropriate technology and techniques significantly improves success rates while reducing patient discomfort and healthcare costs. Healthcare institutions should implement comprehensive DVA protocols with adequate training, equipment access, and quality monitoring. The proposed algorithm achieved a 93% overall success rate in validation studies, representing a substantial improvement over traditional approaches.
Overview
CoChat Summary
TL;DR
This systematic review and meta-analysis of 47 studies (12,847 patients) found that technology-assisted and population-specific strategies improve difficult venous access (DVA) blood sampling, with ultrasound guidance showing the largest first-attempt benefit (RR 1.42) and a proposed stepwise algorithm achieving 93% overall success in validation. It also reports cost savings and implementation factors such as champion-based adoption and simulation training.
Key findings
- Ultrasound-guided venipuncture improved first-attempt success (RR 1.42, 95% CI 1.26–1.58, p < 0.001; NNT 3.2), overall success (RR 1.54, 95% CI 1.40–1.70, p < 0.001; NNT 2.1), reduced complications (RR 0.41, 95% CI 0.33–0.52, p < 0.001), reduced pain by 2.4 VAS points (95% CI 1.8–3.0), and reduced procedure time by 2.2 min (95% CI 1.4–3.0).
- Near-infrared visualization improved first-attempt success (RR 1.28, 95% CI 1.14–1.42, p < 0.001; NNT 4.7), reduced procedure time by 1.8 min (95% CI 0.8–2.8), and showed larger effects in pediatric patients (RR 1.45) than adults (RR 1.18), with benefit in obese patients (RR 1.34) but limited effectiveness with dark skin pigmentation or veins >4 mm deep.
- Population-specific approaches: infant scalp venipuncture had 89% vs 62% first-attempt success (RR 1.43, 95% CI 1.28–1.60, p < 0.001) and lower FLACC pain scores (mean difference −2.1, 95% CI −2.8 to −1.4); external jugular access had 76% first-attempt success (95% CI 71–81%) and 94% overall success (95% CI 91–97%), with 4.2% minor and 0.1% serious complications; forearm venipuncture in elderly patients had 68% vs 51% success (RR 1.33, 95% CI 1.18–1.50).
- Economic and implementation findings: traditional DVA draws averaged $47 per successful draw vs $31–$38 for technology-assisted approaches; a 300-bed hospital could save $285,000–$420,000 annually, with implementation costs of $25,000–$75,000 recovered in 6–18 months. Champion-based implementation had higher adoption (OR 3.2, 95% CI 2.1–4.8), simulation training achieved 87% skill retention at six months vs 54% for didactic training, and the validated stepwise algorithm achieved 93% overall success, reduced mean attempts from 3.2 to 1.4, reduced complications by 67%, and saved 4.3 min per DVA patient.
Methods
- PRISMA-guided systematic review and meta-analysis searching MEDLINE, Embase, CINAHL, and Cochrane Central Register of Controlled Trials, plus manual reference screening and trial registries; inclusion covered randomized controlled trials, systematic reviews, and prospective observational studies published from January 2016 to June 2025 (abstract states January 2016 to December 2023) examining DVA blood sampling strategies in adult and pediatric patients.
- Two independent reviewers screened titles/abstracts and full texts, extracted data with a standardized form, and resolved disagreements by discussion or a third reviewer; quality was assessed with Cochrane RoB 2, Newcastle–Ottawa Scale, and AMSTAR 2.
- Random-effects meta-analyses were performed in Review Manager 5.4 and R, with heterogeneity assessed by I² and subgroup/sensitivity analyses; economic analysis incorporated direct and indirect costs converted to 2023 US dollars. The review included 47 studies, with 41 providing data for quantitative meta-analysis.
Limitations
- The paper states that the meta-analysis could not quantitatively assess learning curves or how success varies by operator experience, and that long-term outcomes such as repeated access success, complication recurrence, and impact on patient throughput and staff efficiency were limited.
- The paper also states that inability to blind interventions in many studies introduced potential performance bias, and that more detailed long-term analysis is needed to fully capture return on investment.
- Evident from the text: the search period is inconsistent between the abstract (January 2016–December 2023) and methods (January 2016–June 2025); quality assessment describes 28 RCTs and 12 prospective cohort studies but does not report quality results for the 5 systematic reviews and 2 quasi-randomized trials included among the 47 studies.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
5 Valid · 19 Not valid · 11 Not checked · 48 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“Seven studies involving 1245 infants [24,25] evaluated scalp vein access compared to peripheral limb venipuncture.”
§ Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis > 3. Results > 3.3. Technology-Assisted Traditional Venipuncture
What the sources say
- Not matchedcites [24] Cho, C., Koser, B.W., and Das, J.M. (2025, December 16). Scalp Vein Catheterization, StatPearls [Internet], Available online: https://www.ncbi.nlm.nih.gov/books/NBK565911/.
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Disputedcites [25] Wei, 2020, A clinical rule for the difficulty prediction on scalp intravenous access in infants, Sci. Rep. sourceExperimental — accuracy not yet measured
The Results (Study characteristics; page unavailable) describe one study enrolling 658 infants, not seven studies involving 1,245 infants. The Discussion mentions limb veins as an option if scalp access fails, but does not report a comparison with limb venipuncture. (LLM, conf=0.87)
Checked by a reasoning model — may be wrong.
plainn = 1,245- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“The results demonstrated remarkable effectiveness with a first-attempt success rate of 89% compared to 62% for peripheral attempts (RR 1.43, 95% CI 1.28–1.60, p < 0.001) [25,26].”
§ Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis > 3. Results > 3.3. Technology-Assisted Traditional Venipuncture
What the sources say
- Disputedcites [25] Wei, 2020, A clinical rule for the difficulty prediction on scalp intravenous access in infants, Sci. Rep. sourceExperimental — accuracy not yet measured
The Discussion reports a 79.8% first-attempt success rate for scalp intravenous access in infants, contrary to the claimed 89%. The Results (Study characteristics; Table 1, page not provided) report 525 successes among 658 scalp attempts; they do not report a 62% peripheral-attempt comparator or the stated RR and confidence interval. (LLM, conf=0.90)
Checked by a reasoning model — may be wrong.
- Disputedcites [26] Zhou, 2025, Effects of Cold and Vibration on Venipuncture Pain Management in Children Aged 2-7 Years Old: Randomized Controlled Trial, JMIR Pediatr. Parent. sourceExperimental — accuracy not yet measured
The Methods (Participants; no page provided) describe children aged 2–7 years, not infants, and the study compares cold and vibration conditions rather than scalp and peripheral access. The Results (Demographic Information, Table 1; no page provided) report first-attempt success rates of 94.6%–100% across those groups, not 89% versus 62%; they do not report the claimed RR, confidence interval, or p-value. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
boostedstates an associationn = 1,245 ·- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
Some cited sources support this claim and some don’t — read each source’s verdict below.
In the paper
“First-attempt success rates improved by 28% (RR 1.28, 95% CI 1.14–1.42, p < 0.001) [15,22,23], with a number needed to treat of 4.7.”
§ Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis > 3. Results > 3.3. Technology-Assisted Traditional Venipuncture
What the sources say
- Partly supportedcites [15] Pan, C.-T., Francisco, M.D., Yen, C.-K., Wang, S.-Y., and Shiue, Y.-L. (2019). Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy. Sensors, 19. sourceExperimental — accuracy not yet measured
Section 4.4 reports higher first-attempt success with a vein finder than with standard care in a prototype test, and Section 3.2 reports first-attempt results from another study. Neither section reports a pooled 28% improvement, RR 1.28, the stated confidence interval or p-value, or a number needed to treat of 4.7. Page numbers were not available in our copy. (LLM, conf=0.88)
- Could not verifycites [22] Ju, 2023, Retrospective analysis of the feasibility and safety of external jugular vein cannulation in surgical patients, Anesth. Pain Med. sourceExperimental — accuracy not yet measured
The Discussion (page unavailable) says the authors could not investigate the success rate of external jugular vein cannulation. Searches for near-infrared visualization and the reported RR and confidence interval found no passage comparing first-attempt success with traditional venipuncture. (LLM, conf=0.78)
- Disputedcites [23] Akarca, 2022, Comparison of standard technique, ultrasonography, and near-infrared light in difficult peripheral vascular access: A randomized controlled trial, Prehospital Disaster Med. sourceExperimental — accuracy not yet measured
The Abstract reports first-attempt success of 58.9% with near-infrared light versus 62.2% with the standard method, with no significant difference (P = .648). The Discussion explicitly says the study did not find near-infrared light superior to the standard method in adults with difficult vascular access, contrary to the claimed 28% improvement. (LLM, conf=0.95)
Checked by a reasoning model — may be wrong.
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“Eight studies with 986 adult patients [11] examined external jugular venipuncture in extreme DVA cases.”
§ Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis > 3. Results > 3.3. Technology-Assisted Traditional Venipuncture
What the sources say
- Disputedcites [11] Christensen, 2022, Arterial and venous blood sampling is equally applicable for coagulation and fibrinolysis analyses, Clin. Chem. Lab. Med. sourceExperimental — accuracy not yet measured
The Abstract describes one comparative cohort study of 100 patients, not eight studies involving 986 patients. The Blood sampling section specifies antecubital venipuncture and radial-artery cannulation, rather than external jugular venipuncture in extreme DVA cases. (LLM, conf=0.90)
Checked by a reasoning model — may be wrong.
plainn = 986- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“Eighteen studies involving 3924 patients [13,14,15] evaluated ultrasound-guided venipuncture compared to traditional techniques.”
§ Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis > 3. Results > 3.3. Technology-Assisted Traditional Venipuncture
What the sources say
- Could not verifycites [13] Gala, 2024, The economic burden of difficult intravenous access in the emergency department from a United States’ provider perspective, J. Res. Nurs. sourceExperimental — accuracy not yet measured
The Abstract (page unavailable) describes an economic decision-tree model using parameters from a targeted literature review, not an evaluation of 18 studies involving 3,924 patients. Searches for the study and patient counts and for an ultrasound-guided versus traditional venipuncture comparison found no passage stating the claim. (LLM, conf=0.75)
- Not checked — no full text of the sourcecites [14] Koike, 2025, Impact of the Warm Compress Method Conducted by Nurses Before Venipuncture on Blood Nitric Oxide Concentration, J. Infus. Nurs. source
- Could not verifycites [15] Pan, C.-T., Francisco, M.D., Yen, C.-K., Wang, S.-Y., and Shiue, Y.-L. (2019). Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy. Sensors, 19. sourceExperimental — accuracy not yet measured
Section 3.2 compares near-infrared vein finders with conventional visualization or palpation, and Section 4.4 discusses 21 prototype studies. Searches for ultrasound-guided venipuncture, 18 studies, and 3,924 patients found no passage in our copy reporting the claimed comparison or totals. (LLM, conf=0.74)
plainn = 3,924- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
52 more claims · 9 with their cited sources checked
Create a free account to see all 83 claims and every source verdict.
- Probably not a substantial claim. 11
- It may state two separate claims as one. 15
- Borderline: one of the tests for a substantial claim is unclear. 1
- The quote only partly states this claim. 2
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis > Abstract
“We searched MEDLINE, Embase, CINAHL, and Cochrane databases from January 2016 to December 2023.”
§ Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis > 2. Materials and Methods > 2.3. Eligibility Criteria
“Inclusion Criteria: Randomized controlled trials, systematic reviews, and prospective observational studies published from January 2016 to June 2025.”
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis > 3. Results > 3.3. Technology-Assisted Traditional Venipuncture
“The overall success rates demonstrated even more impressive results (RR 1.54, 95% CI 1.40–1.70, p < 0.001) [13,14,15], with a number needed to treat of 2.1.”
§ Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis > 3. Results > 3.3. Technology-Assisted Traditional Venipuncture
“The overall success rates demonstrated even more impressive results (RR 1.54, 95% CI 1.40–1.70, p < 0.001) [13,14,15], with a number needed to treat of 2.1.”
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis > 3. Results > 3.3. Technology-Assisted Traditional Venipuncture
“First-attempt success rates showed a dramatic improvement with ultrasound guidance (RR 1.42, 95% CI 1.26–1.58, p < 0.001) [13,14,15], corresponding to a number needed to treat of 3.2 patients.”
§ Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis > 3. Results > 3.3. Technology-Assisted Traditional Venipuncture
“The absolute risk difference was 31% (95% CI 24–38%), indicating that for every 100 DVA patients, ultrasound guidance would result in 31 additional successful first attempts.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis > 3. Results > 3.3. Technology-Assisted Traditional Venipuncture
“the subsequent Section 3.4 addresses population-specific anatomical and physiological considerations that may require alternative access sites or specialized approaches.”
§ Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis > 3. Results > 3.4. Economic Impact Analysis
“### 3.4. Economic Impact Analysis”
Citations
Cites
Infusion Therapy Standards of Practice, 8th Edition
Gorski, L. A., Hadaway, L., Hagle, M. E., Broadhurst, D., Clare, S., Kleidon, T., Meyer, B. M., Nickel, B., Rowley, S., Sharpe, E., et al. (2021) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000396 · Cited by 1,032 · cited 1×
“Regarding whether all patients should receive ultrasound-guided venipuncture, our analysis supports a risk-stratified approach rather than universal implementation [28].”
International evidence-based recommendations on ultrasound-guided vascular access
Lamperti, M., Bodenham, A. R., Pittiruti, M., Blaivas, M., Augoustides, J. G., Elbarbary, M., Pirotte, T., Karakitsos, D., LeDonne, J., Doniger, S., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2597-x · Cited by 834 · cited 1×
“…access; (3) high-stakes situations where multiple attempts would be particularly detrimental (e.g., chemotherapy patients, pediatric populations, patients with bleeding disorders); and (4) settings where reducing procedure time and improving first-attempt success are critical priorities [29].”
Birnie, K. A., Noel, M., Chambers, C. T., Uman, L. S., & Parker, J. A. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005179.pub4 · Cited by 755
Reducing pain during vaccine injections: clinical practice guideline
Taddio, A., McMurtry, C. M., Shah, V., Riddell, R. P., Chambers, C. T., Noel, M., MacDonald, N. E., Rogers, J., Bucci, L. M., Mousmanis, P., et al. (2015) · Canadian Medical Association Journal · doi:10.1503/cmaj.150391 · Cited by 290 · cited 1×
“Patient discomfort was evaluated across the included studies using validated assessment instruments including the Visual Analog Scale (VAS) for pain (0–10), the Numeric Rating Scale (NRS), and procedure-specific anxiety measures [19,20].”
Ultrasound guidance for difficult peripheral venous access: Systematic review and meta-analysis
Egan, G., Healy, D., O'Neill, H., Clarke-Moloney, M., Grace, P. A., & Walsh, S. R. (2013) · Emergency Medicine Journal · doi:10.1136/emermed-2012-201652 · Cited by 222 · cited 1×
“Meta-analysis of pain scores demonstrated a mean reduction of 2.4 points on VASs (95% CI 1.8–3.0, p 0.001) with ultrasound guidance compared to traditional techniques [21].”
InfluentialUltrasound-guided peripheral venous access: A meta-analysis and systematic review
Stolz, L. A., Stolz, U., Howe, C., Farrell, I. J., & Adhikari, S. (2015) · The Journal of Vascular Access · doi:10.5301/jva.5000346 · Cited by 189 · cited 1×
“Study quality was assessed using the Cochrane Risk of Bias tool (RoB 2) [6] for randomized controlled trials, the Newcastle–Ottawa Scale [7] for observational studies, and AMSTAR 2 [12] for systematic reviews.”
van Loon, F. H. J., van Hooff, L. W. E., de Boer, H. D., Koopman, S. S. H. A., Buise, M. P., Korsten, H. H. M., Dierick-van Daele, A. T. M., & Bouwman, A. R. A. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8020144 · Cited by 157
Bahl, A., Pandurangadu, A. V., Tucker, J., & Bagan, M. (2016) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2016.06.098 · Cited by 146 · cited 1×
“%) specifically enrolled patients meeting DVA criteria, while 4 studies included mixed populations with subgroup analyses for DVA patients, allowing for the direct assessment of ultrasound efficacy in this target population [16,17].”
A clinical pathway for the management of difficult venous access
Sou, V., McManus, C., Mifflin, N., Frost, S. A., Ale, J., & Alexandrou, E. (2017) · BMC Nursing · doi:10.1186/s12912-017-0261-z · Cited by 137 · cited 1×
“%) also included access to deeper veins (1.5–3.0 cm depth) when superficial options were exhausted, with ultrasound proving particularly advantageous for deeper vessel visualization [18].”
Influentialvan Loon (2016) · doi:10.1097/md.0000000000003428 · Cited by 124
Research works printed but not linked: 1
- Cho, C., Koser, B.W., and Das, J.M. (2025, December 16). Scalp Vein Catheterization, StatPearls [Internet], Available online: https://www.ncbi.nlm.nih.gov/books/NBK565911/.
Cited by
Ekinci, A. (2026) · Journal of Health Sciences and Medicine · doi:10.32322/jhsm.1932008
Metadata
- Authors
- Mussa, B., Passarella, G., Marchese, M., & Defrancisco, B.
- Affiliations
- University of Turin (IT)
- Corresponding author
- Mussa, Baudolino
- ORCID
- Mussa, Baudolino
- Venue
- Medicina
- Publisher
- MDPI AG
- Published
- 2026-03-23
- Volume
- 62
- Issue
- 3
- Pages
- 604
- ISSN
- 1010-660X (ISSN-L)
- 1648-9144
- PMC
- PMC13027773
- OpenAlex
- W7140109477
- Cited by
- 2
- References
- 30
- Citations by year
- 2026: 2
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Medicina (publishedVersion, cc-by)
- Preprints.org (acceptedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Institutional Research Information System University of Turin (University of Turin) (submittedVersion, other-oa)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- difficult venous access, blood sampling, ultrasound-guided venipuncture, first-attempt success rate, external jugular vein, cost-effectiveness, patient discomfort
- MeSH terms
- Blood Specimen Collection, Humans, Phlebotomy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-09-30, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-09-30 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis. https://app.cochat.ai/papers/10.3390/medicina62030604
- The paper
- Mussa, B., Passarella, G., Marchese, M., & Defrancisco, B. (2026). Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis. Medicina. https://doi.org/10.3390/medicina62030604
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.