Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 159

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Three-Dimensional Analysis of High-Resolution X-Ray Computed Tomography Data with Morpho+

Brabant, Loes, Vlassenbroeck, Jelle, De Witte, Yoni, Cnudde, Veerle, Boone, Matthieu N., Dewanckele, Jan, Van Hoorebeke, Luc · 2011 · Microscopy and Microanalysis

Abstract

Three-dimensional (3D) analysis is an essential tool to obtain quantitative results from 3D datasets. Considerable progress has been made in 3D imaging techniques, resulting in a growing need for more flexible, complete analysis packages containing advanced algorithms. At the Centre for X-ray Tomography of the Ghent University (UGCT), research is being done on the improvement of both hardware and software for high-resolution X-ray computed tomography (CT). UGCT collaborates with research groups from different disciplines, each having specific needs. To meet these requirements the analysis software package, Morpho+, was developed in-house. Morpho+ contains an extensive set of high-performance 3D operations to obtain object segmentation, separation, and parameterization (orientation, maximum opening, equivalent diameter, sphericity, connectivity, etc.), or to extract a 3D geometrical representation (surface mesh or skeleton) for further modeling. These algorithms have a relatively short processing time when analyzing large datasets. Additionally, Morpho+ is equipped with an interactive and intuitive user interface in which the results are visualized. The package allows scientists from various fields to obtain the necessary quantitative results when applying high-resolution X-ray CT as a research tool to the nondestructive investigation of the microstructure of materials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s1431927610094389

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 159

Metadata

Authors
Brabant, L., Vlassenbroeck, J., De Witte, Y., Cnudde, V., Boone, M. N., Dewanckele, J., & Van Hoorebeke, L.
Venue
Microscopy and Microanalysis
Published
2011-01-31
Volume
17
Issue
2
Pages
252-263
ISSN
  • 1431-9276 (ISSN-L)
  • 1435-8115
OpenAlex
W2020465198
Cited by
159
References
1
FWCI
17.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Three-Dimensional Analysis of High-Resolution X-Ray Computed Tomography Data with Morpho+. https://app.cochat.ai/papers/10.1017/s1431927610094389
The paper
Brabant, L., Vlassenbroeck, J., De Witte, Y., Cnudde, V., Boone, M. N., Dewanckele, J., & Van Hoorebeke, L. (2011). Three-Dimensional Analysis of High-Resolution X-Ray Computed Tomography Data with Morpho+. Microscopy and Microanalysis. https://doi.org/10.1017/s1431927610094389

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.