Three-Dimensional Analysis of High-Resolution X-Ray Computed Tomography Data with Morpho+
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Three-dimensional (3D) analysis is an essential tool to obtain quantitative results from 3D datasets. Considerable progress has been made in 3D imaging techniques, resulting in a growing need for more flexible, complete analysis packages containing advanced algorithms. At the Centre for X-ray Tomography of the Ghent University (UGCT), research is being done on the improvement of both hardware and software for high-resolution X-ray computed tomography (CT). UGCT collaborates with research groups from different disciplines, each having specific needs. To meet these requirements the analysis software package, Morpho+, was developed in-house. Morpho+ contains an extensive set of high-performance 3D operations to obtain object segmentation, separation, and parameterization (orientation, maximum opening, equivalent diameter, sphericity, connectivity, etc.), or to extract a 3D geometrical representation (surface mesh or skeleton) for further modeling. These algorithms have a relatively short processing time when analyzing large datasets. Additionally, Morpho+ is equipped with an interactive and intuitive user interface in which the results are visualized. The package allows scientists from various fields to obtain the necessary quantitative results when applying high-resolution X-ray CT as a research tool to the nondestructive investigation of the microstructure of materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398 · cited 1×
“This interval can be manually selected or calculated automatically by using Otsu’s method ~ Otsu, 1979 !”
MethodThe Fractal Geometry of Nature
Mandelbrot, B. B., & Wheeler, J. A. (1983) · American Journal of Physics · doi:10.1119/1.13295 · Cited by 21,832
Bilateral Filtering for Gray and Color Images
Tomasi, C., & Manduchi, R. (2002) · Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271) · doi:10.1109/iccv.1998.710815 · Cited by 8,177
The Fractal Geometry of Nature
Mandelbrot, B. B., & Longley, P. (1982) · CERN Document Server (European Organization for Nuclear Research) · Cited by 7,293
Watersheds in digital spaces: an efficient algorithm based on immersion simulations
Vincent, L., & Soille, P. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.87344 · Cited by 5,649 · cited 1×
“To perform this segmentation, a Watershed-based separation procedure is used, for which the already calculated distance transform is used as input ~ Vincent & Soille, 1991 !”
MethodThe Art of Computer Programming. Volume 1: Fundamental Algorithms.
Odeh, R. E., & Knuth, D. E. (1969) · Journal of the American Statistical Association · doi:10.2307/2283757 · Cited by 2,525 · cited 1×
“In Morpho (cid:2) , a series of algorithms to detect the connected components is used ~ Rosenfeld & Pfaltz, 1966; Knuth, 1997 !”
BackgroundSoille, P. (1999) · Springer eBooks · doi:10.1007/978-3-662-03939-7 · Cited by 1,977
A new method for the model‐independent assessment of thickness in three‐dimensional images
Hildebrand, T., & Rüegsegger, P. (1997) · Journal of Microscopy · doi:10.1046/j.1365-2818.1997.1340694.x · Cited by 1,818 · cited 1×
“The maximal spheres method ~ Hildebrand & Rüegsegger, 1997 ! is most commonly used.”
MethodSequential Operations in Digital Picture Processing
Rosenfeld, A., & Pfaltz, J. L. (1966) · Journal of the ACM · doi:10.1145/321356.321357 · Cited by 1,675 · cited 1×
“In Morpho (cid:2) , a series of algorithms to detect the connected components is used ~ Rosenfeld & Pfaltz, 1966; Knuth, 1997 !”
BackgroundCurve-Skeleton Properties, Applications, and Algorithms
Cornea, N. D., Silver, D., & Min, P. (2007) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2007.1002 · Cited by 484 · cited 1×
“Various skeletonization algorithms exist with varying complexity ~ Cornea et al., 2007 !”
BackgroundSoftware tools for quantification of X-ray microtomography at the UGCT
Vlassenbroeck, J., Dierick, M., Masschaele, B., Cnudde, V., Van Hoorebeke, L., & Jacobs, P. (2007) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2007.05.073 · Cited by 380 · cited 2×
“, including the design and construction of scanners, the data acquisition, and the reconstruction with the in-house developed software package Octopus ~ Vlassenbroeck et al., 2007 !”
MethodSelf-citationKetcham, R. A. (2005) · Geosphere · doi:10.1130/ges00001.1 · Cited by 362
UGCT: New X-ray radiography and tomography facility
Masschaele, B. C., Cnudde, V., Dierick, M., Jacobs, P., Van Hoorebeke, L., & Vlassenbroeck, J. (2007) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2007.05.099 · Cited by 204
Self-citationPlant structure visualization by high-resolution X-ray computed tomography
Dhondt, S., Vanhaeren, H., Van Loo, D., Cnudde, V., & Inzé, D. (2010) · Trends in Plant Science · doi:10.1016/j.tplants.2010.05.002 · Cited by 185 · cited 1×
“, biotechnology ~ Savina et al., 2007; Dhondt et al., 2010 !”
BackgroundSelf-citationPore3D: A software library for quantitative analysis of porous media
Brun, F., Mancini, L., Kasae, P., Favretto, S., Dreossi, D., & Tromba, G. (2010) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2010.02.063 · Cited by 159 · cited 1×
“, Pore3D ~ Brun et al., 2010 !”
Savina, I. N., Cnudde, V., D'hollander, S., Hoorebeke, L. V., Mattìasson, B., Galaev, I. Y., & Prez, F. D. (2007) · Soft Matter · doi:10.1039/b706654f · Cited by 138 · cited 1×
“, biotechnology ~ Savina et al., 2007; Dhondt et al., 2010 !”
BackgroundSelf-citationSleutel, S., Cnudde, V., Masschaele, B., Vlassenbroeck, J., Dierick, M., Hoorebeke, L. V., Jacobs, P., & Neve, S. D. (2008) · Computers & Geosciences · doi:10.1016/j.cageo.2007.10.006 · Cited by 112 · cited 1×
“, soil science ~ Sleutel et al., 2008; Pirlet et al., 2010 !”
BackgroundSelf-citationPIRLET, H., WEHRMANN, L. M., BRUNNER, B., FRANK, N., DEWANCKELE, J., VAN ROOIJ, D., FOUBERT, A., SWENNEN, R., NAUDTS, L., BOONE, M., et al. (2010) · Sedimentology · doi:10.1111/j.1365-3091.2009.01119.x · Cited by 90 · cited 1×
“, soil science ~ Sleutel et al., 2008; Pirlet et al., 2010 !”
BackgroundSelf-citationSpeijer, R. P., Loo, D. V., Masschaele, B., Vlassenbroeck, J., Cnudde, V., & Jacobs, P. J. S. (2008) · Geosphere · doi:10.1130/ges00176.1 · Cited by 78 · cited 1×
“Morpho (cid:2) is used in geology ~ Speijer et al., 2008; Cnudde et al., 2009; Dewanckele et al., 2009; Foubert & Henriet, 2009 !”
MethodSelf-citationThree-Dimensional X-Ray Imaging and Analysis of Fungi on and in Wood
den Bulcke, J. V., Boone, M., Acker, J. V., & Hoorebeke, L. V. (2009) · Microscopy and Microanalysis · doi:10.1017/s1431927609990419 · Cited by 70 · cited 2×
“The Scots pine wood sample was used in the scope of research concerning the effect of exposure of wood to fungi ~ Van den Bulcke et al., 2009 b !”
BackgroundMethodSelf-citation
Cited by
Cnudde, V., & Boone, M. N. (2013) · Earth-Science Reviews · doi:10.1016/j.earscirev.2013.04.003 · Cited by 1,572
Self-citationMaire, E., & Withers, P. J. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000023 · Cited by 1,374
Bultreys, T., De Boever, W., & Cnudde, V. (2016) · Earth-Science Reviews · doi:10.1016/j.earscirev.2016.02.001 · Cited by 474
Self-citationComparison of different approaches for self-healing concrete in a large-scale lab test
Van Tittelboom, K., Wang, J., Araújo, M., Snoeck, D., Gruyaert, E., Debbaut, B., Derluyn, H., Cnudde, V., Tsangouri, E., Van Hemelrijck, D., et al. (2016) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2015.12.186 · Cited by 226
Self-citationX-ray microtomography in biology
Mizutani, R., & Suzuki, Y. (2012) · Micron · doi:10.1016/j.micron.2011.10.002 · Cited by 217
Metadata
- Authors
- Brabant, L., Vlassenbroeck, J., De Witte, Y., Cnudde, V., Boone, M. N., Dewanckele, J., & Van Hoorebeke, L.
- Venue
- Microscopy and Microanalysis
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-01-31
- Volume
- 17
- Issue
- 2
- Pages
- 252-263
- ISSN
- 1431-9276 (ISSN-L)
- 1435-8115
- OpenAlex
- W2020465198
- Cited by
- 159
- References
- 20
- FWCI
- 17.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.