An Improved Mean Atomic Number Background Correction for Quantitative Microanalysis
The DOI matches its Crossref record.
Abstract
Quantitative EPMA (electron probe microanalysis) intensity measurements require an accurate correction for the X-ray continuum (or background) created by the Bremsstrahlung effect from the primary electron beam. This X-ray continuum, as measured on a wavelength-dispersive spectrometer at any particular wavelength, is primarily a function of the mean atomic number of the material being analyzed. One can calibrate the dependence of the continuum on mean atomic number by measuring and curve fitting the X-ray intensities at the analytical peak in pure elements, oxides, and binary compound standards that do not contain any of the analyte or any interfering elements and use that calibration to calculate the X-ray background correction. For unknown samples, the mean atomic number is determined from the elemental concentrations calculated by the ZAF or φ(ρz) matrix correction, and the fit regression coefficients are used iteratively to calculate the actual background correction. Over a large range of mean atomic number we find that the dependence of the continuum intensity on mean atomic number is well described by a second-order polynomial fit. In the case of low-energy X-ray lines (<1 to 2 keV), this fit is significantly improved by correcting the X-ray continuum intensities for absorption. For major and most minor element analyses, the improved mean atomic number background correction procedure presented in this paper is accurate and robust for a wide variety of samples. Empirical mean atomic number background data are presented for a typical 10-element silicate and a 15-element sulfide analytical set up that demonstrate the validity of the technique as well as some potential limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kuehn, S. C., Froese, D. G., & Shane, P. A. R. (2011) · Quaternary International · doi:10.1016/j.quaint.2011.08.022 · Cited by 276
Jercinovic, M. J. (2005) · American Mineralogist · doi:10.2138/am.2005.1422 · Cited by 240
Quantitative compositional mapping of mineral phases by electron probe micro-analyser
Lanari, P., Vho, A., Bovay, T., Airaghi, L., & Centrella, S. (2019) · Geological Society, London, Special Publications · doi:10.1144/sp478.4 · Cited by 216
“The MAN algorithm for instance allows the background value to be predicted from the mean atomic number of the specimen (Donovan & Tingle 2003; Chouinard & Donovan 2015; Wark & Donovan 2017), significantly reducing the total acquisition time.”
Śliwiński, M. G., Kitajima, K., Spicuzza, M. J., Orland, I. J., Ishida, A., Fournelle, J. H., & Valley, J. W. (2018) · Geostandards and Geoanalytical Research · doi:10.1111/ggr.12194 · Cited by 37
Scibiorski, E., Jourdan, F., Mezger, K., Tohver, E., & Vollstaedt, H. (2021) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2021.09.017 · Cited by 24
Metadata
- Authors
- Donovan, J. J., & Tingle, T. N.
- Venue
- Microscopy and Microanalysis
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-02
- Volume
- 2
- Issue
- 1
- Pages
- 1-7
- ISSN
- 1431-9276 (ISSN-L)
- 1435-8115
- OpenAlex
- W2064819586
- Cited by
- 255
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.