Seeing or believing in hyperplexed spatial proteomics via antibodies: New and old biases for an image-based technology
Open accessPublished version of a preprint
The DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
Hyperplexed in-situ targeted proteomics via antibody immunodetection (i.e., >15 markers) is changing how we classify cells and tissues. Differently from other high-dimensional single-cell assays (flow cytometry, single-cell RNA sequencing), the human eye is a necessary component in multiple procedural steps: image segmentation, signal thresholding, antibody validation, and iconographic rendering. Established methods complement the human image evaluation, but may carry undisclosed biases in such a new context, therefore we re-evaluate all the steps in hyperplexed proteomics. We found that the human eye can discriminate less than 64 out of 256 gray levels and has limitations in discriminating luminance levels in conventional histology images. Furthermore, only images containing visible signals are selected and eye-guided digital thresholding separates signal from noise. BRAQUE, a hyperplexed proteomic tool, can extract, in a marker-agnostic fashion, granular information from markers which have a very low signal-to-noise ratio and therefore are not visualized by traditional visual rendering. By analyzing a public human lymph node dataset, we also found unpredicted staining results by validated antibodies, which highlight the need to upgrade the definition of antibody specificity in hyperplexed immunostaining. Spatially hyperplexed methods upgrade and supplant traditional image-based analysis of tissue immunostaining, beyond the human eye contribution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This increasing dimensionality in digital images further stimulates the development of advanced tools for image analyses and data extraction that go beyond what the experimenter’s eye, which is perhaps unconsciously biased but surely biologically limited, may see [345].”
From Inflammation and immunity in liver homeostasis and disease: a nexus of hepatocytes, nonparenchymal cells and immune cells (2025) · doi:10.1038/s41423-025-01313-7 · cites this paper as [345]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiji: an open-source platform for biological-image analysis
Schindelin, J., Arganda-Carreras, I., Frise, E., Kaynig, V., Longair, M., Pietzsch, T., Preibisch, S., Rueden, C., Saalfeld, S., Schmid, B., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2019 · Cited by 66,890 · cited 1×
“After the stainings were acquired, digital slide images (.ndpi) were imported as uncompressed .tiff with ImageJ (ImageJ, RRID:SCR_003070).”
MethodQuPath: Open source software for digital pathology image analysis
Bankhead, P., Loughrey, M. B., Fernández, J. A., Dombrowski, Y., McArt, D. G., Dunne, P. D., McQuaid, S., Gray, R. T., Murray, L. J., Coleman, H. G., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-17204-5 · Cited by 8,908 · cited 1×
“Image analysis IHC / IF staining quantitation Adobe Photoshop 2023 (San Jose, CA) (RRID:SCR_014199) and Adobe Illustrator(RRID:SCR_010279) were used for figure layouts.”
Quantification of histochemical staining by color deconvolution.
Ruifrok, A. C. C., & Johnston, D. A. (2001) · PubMed · Cited by 2,568
Single-cell RNA-seq reveals new types of human blood dendritic cells, monocytes, and progenitors
Villani, A.-C., Satija, R., Reynolds, G., Sarkizova, S., Shekhar, K., Fletcher, J., Griesbeck, M., Butler, A., Zheng, S., Lazo, S., et al. (2017) · Science · doi:10.1126/science.aah4573 · Cited by 2,413
Cellpose 2.0: how to train your own model
Pachitariu, M., & Stringer, C. (2022) · Nature Methods · doi:10.1038/s41592-022-01663-4 · Cited by 1,581 · cited 1×
“Image analysis IHC / IF staining quantitation Adobe Photoshop 2023 (San Jose, CA) (RRID:SCR_014199) and Adobe Illustrator(RRID:SCR_010279) were used for figure layouts.”
Amir, E.-A. D., Davis, K. L., Tadmor, M. D., Simonds, E. F., Levine, J. H., Bendall, S. C., Shenfeld, D. K., Krishnaswamy, S., Nolan, G. P., & Pe'er, D. (2013) · Nature Biotechnology · doi:10.1038/nbt.2594 · Cited by 1,550 · cited 1×
“Note that DRAAPs can identify cells not only based on present, but also on absent markers [66].”
BackgroundSchürch, C. M., Bhate, S. S., Barlow, G. L., Phillips, D. J., Noti, L., Zlobec, I., Chu, P., Black, S., Demeter, J., McIlwain, D. R., et al. (2020) · Cell · doi:10.1016/j.cell.2020.07.005 · Cited by 1,064
Best practices for single-cell analysis across modalities
Heumos, L., Schaar, A. C., Lance, C., Litinetskaya, A., Drost, F., Zappia, L., Lücken, M. D., Strobl, D. C., Henao, J., Curion, F., et al. (2023) · Nature Reviews Genetics · doi:10.1038/s41576-023-00586-w · Cited by 1,051 · cited 1×
“(11,12) Analogously to FCM and scRNAseq, human visual image assessment is minimal or nil for these processes, despite the ground truth data which are tissue images.”
BackgroundExponential scaling of single-cell RNA-seq in the past decade
Svensson, V., Vento-Tormo, R., & Teichmann, S. A. (2018) · Nature Protocols · doi:10.1038/nprot.2017.149 · Cited by 1,034 · cited 1×
“Bioinformatic pipelines developed to deal with high-dimensional datasets such as single-cell RNA sequencing or multiparameter flow cytometry have been adapted to analogous types of data derived from tissue, and co-exist with conventional image analysis tools and human eye-guided image evaluation.”
MethodImmunolocalization of keratin polypeptides in human epidermis using monoclonal antibodies
Woodcock-Mitchell, J. (1982) · The Journal of Cell Biology · doi:10.1083/jcb.95.2.580 · Cited by 761 · cited 1×
“…expressed in thin dendrites of fibroblastic reticular cells (FRC), and we found that commonly used thresholding algorithms to quantify IF immunostains fail to account for positive pixels at the low end of the spectrum, despite being visible to the human eye after image rendering (Figure 5).”
BackgroundMapping the human DC lineage through the integration of high-dimensional techniques
See, P., Dutertre, C.-A., Chen, J., Günther, P., McGovern, N., Irac, S. E., Gunawan, M., Beyer, M., Händler, K., Duan, K., et al. (2017) · Science · doi:10.1126/science.aag3009 · Cited by 574
Deep Visual Proteomics defines single-cell identity and heterogeneity
Mund, A., Coscia, F., Kriston, A., Hollandi, R., Kovács, F., Brunner, A.-D., Migh, E., Schweizer, L., Santos, A., Bzorek, M., et al. (2022) · Nature Biotechnology · doi:10.1038/s41587-022-01302-5 · Cited by 562
Computational flow cytometry: helping to make sense of high-dimensional immunology data
Saeys, Y., Van Gassen, S., & Lambrecht, B. N. (2016) · Nature Reviews Immunology · doi:10.1038/nri.2016.56 · Cited by 467 · cited 1×
“Manual gating (i.e., the application of a threshold/barrier discriminating two sets of variables) is considered the main source of data variability and inconsistency in FCM, (8,42,43) but has never been addressed in tissue staining.”
BackgroundInterpreting flow cytometry data: a guide for the perplexed
Herzenberg, L. A., Tung, J., Moore, W. A., Herzenberg, L. A., & Parks, D. R. (2006) · Nature Immunology · doi:10.1038/ni0706-681 · Cited by 464 · cited 1×
“(6) An acceleration of the evolution of the technique was brought by the use of metal-conjugated antibodies and mass spectrometry for detection (Cytometry by time of flight; CYTOF), in lieu of photodetectors and photomultipliers.”
MethodAeffner, F., Zarella, M. D., Buchbinder, N., Bui, M. M., Goodman, M. R., Hartman, D. J., Lujan, G. M., Molani, M. A., Parwani, A. V., Lillard, K., et al. (2019) · Journal of Pathology Informatics · doi:10.4103/jpi.jpi_82_18 · Cited by 403 · cited 1×
“We also found that the granular analytical power of recent bioinformatic pipelines can extract information from images which defy human eye perception and deliver information unattainable with existing image analysis tools for single-stain images.”
BackgroundTaube, J. M., Akturk, G., Angelo, M., Engle, E. L., Gnjatic, S., Greenbaum, S., Greenwald, N. F., Hedvat, C. V., Hollmann, T. J., Juco, J., et al. (2020) · Journal for ImmunoTherapy of Cancer · doi:10.1136/jitc-2019-000155 · Cited by 283
Monitoring T cell–dendritic cell interactions in vivo by intercellular enzymatic labelling
Pasqual, G., Chudnovskiy, A., Tas, J. M. J., Agudelo, M., Schweitzer, L. D., Cui, A., Hacohen, N., & Victora, G. D. (2018) · Nature · doi:10.1038/nature25442 · Cited by 270
Hewitt, S. M., Baskin, D. G., Frevert, C. W., Stahl, W. L., & Rosa-Molinar, E. (2014) · Journal of Histochemistry & Cytochemistry · doi:10.1369/0022155414545224 · Cited by 234
The end of gating? An introduction to automated analysis of high dimensional cytometry data
Mair, F., Hartmann, F. J., Mrdjen, D., Tosevski, V., Krieg, C., & Becher, B. (2016) · European Journal of Immunology · doi:10.1002/eji.201545774 · Cited by 234 · cited 3×
“Manual gating (i.e., the application of a threshold/barrier discriminating two sets of variables) is considered the main source of data variability and inconsistency in FCM, (8,42,43) but has never been addressed in tissue staining.”
BackgroundCytoskeletal components of lymphoid organs
Franke, W. W., & Moll, R. (1987) · Differentiation · doi:10.1111/j.1432-0436.1987.tb00189.x · Cited by 229
Clarke, Z. A., Andrews, T. S., Atif, J., Pouyabahar, D., Innes, B. T., MacParland, S. A., & Bader, G. D. (2021) · Nature Protocols · doi:10.1038/s41596-021-00534-0 · Cited by 226 · cited 1×
“(11,12) Analogously to FCM and scRNAseq, human visual image assessment is minimal or nil for these processes, despite the ground truth data which are tissue images.”
BackgroundFluorochrome-labeled Tyramides: Use in Immunocytochemistry and Fluorescence In Situ Hybridization
Gijlswijk, R. P. M. V., Zijlmans, H. J. M. A. A., Wiegant, J., Bobrow, M. N., Erickson, T. J., Adler, K. E., Tanke, H. J., & Raap, A. K. (1997) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215549704500305 · Cited by 203 · cited 1×
“…(~7-10 biomarkers) are increasingly diffuse, partly owing to the popularity of a signal-enhanced technique (Tyramide Signal Amplification or TSA [9]), however, the Image analysis (IA) required for this type of staining does not differ from what is customarily used for single stain images in IHC…”
Analysis of multispectral imaging with the AstroPath platform informs efficacy of PD-1 blockade
Berry, S., Giraldo, N. A., Green, B. F., Cottrell, T. R., Stein, J. E., Engle, E. L., Xu, H., Ogurtsova, A., Roberts, C., Wang, D., et al. (2021) · Science · doi:10.1126/science.aba2609 · Cited by 199 · cited 1×
“As previously published by others, (34,35) TSA was not superior, compared to DAB, and as good as double indirect IF (20) for some fluorochromes (Figure 4).”
Discriminating gene expression profiles of memory B cell subpopulations
Ehrhardt, G. R. A., Hijikata, A., Kitamura, H., Ohara, O., Wang, J.-Y., & Cooper, M. D. (2008) · The Journal of Experimental Medicine · doi:10.1084/jem.20072682 · Cited by 198 · cited 1×
“The staining pattern of in-house CK staining of the lymph node reproduced what was obtained from the CODEX dataset, including the follicular B cell staining (Figure 7b).”
The Gold Standard Paradox in Digital Image Analysis: Manual Versus Automated Scoring as Ground Truth
Aeffner, F., Wilson, K., Martin, N. T., Black, J. C., Hendriks, C. L. L., Bolon, B., Rudmann, D. G., Gianani, R., Koegler, S. R., Krueger, J., et al. (2017) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2016-0386-ra · Cited by 190 · cited 2×
“The type of images of this test (homogeneously tinted squares surrounded by a thick border) are not the type of images encountered in medicine or biology and may be also prone to hallucinations [33].”
BackgroundNuclear and cytoplasmic AID in extrafollicular and germinal center B cells
Cattoretti, G., Büttner, M., Shaknovich, R., Kremmer, E., Alobeid, B., & Niedobitek, G. (2006) · Blood · doi:10.1182/blood-2005-10-4170 · Cited by 174 · cited 1×
“The staining pattern of in-house CK staining of the lymph node reproduced what was obtained from the CODEX dataset, including the follicular B cell staining (Figure 7b).”
MethodSelf-citationLi, C. Y., Ziesmer, S. C., & Lazcano-Villareal, O. (1987) · Journal of Histochemistry & Cytochemistry · doi:10.1177/35.12.2824601 · Cited by 171
Multiplex Staining by Sequential Immunostaining and Antibody Removal on Routine Tissue Sections
Bolognesi, M. M., Manzoni, M., Scalia, C. R., Zannella, S., Bosisio, F. M., Faretta, M., & Cattoretti, G. (2017) · Journal of Histochemistry & Cytochemistry · doi:10.1369/0022155417719419 · Cited by 168 · cited 7×
“Sections to be processed for TSA were dewaxed, antigen retrieval was performed as mentioned, endogenous peroxidase was blocked, incubated with the primary Ab overnight and processed as per the manufacturer ’ s instruction for Alexa Fluor ™ 647 Tyramide (cat.”
BackgroundMethodInfluentialSelf-citationIncreasing the Number of Gray Shades in Medical Display Systems—How Much is Enough?
Kimpe, T., & Tuytschaever, T. (2007) · Journal of Digital Imaging · doi:10.1007/s10278-006-1052-3 · Cited by 161 · cited 1×
“Published research shows that humans can distinguish about 870 different shades of gray, (31) data which are contradicted by Kreit et al., (32) who sets the gray level discrimination in humans at about 30 shades.”
BackgroundIntegrated Cross-Species Analysis Identifies a Conserved Transitional Dendritic Cell Population
Leylek, R., Alcántara-Hernández, M., Lanzar, Z., Lüdtke, A., Perez, O. A., Reizis, B., & Idoyaga, J. (2019) · Cell Reports · doi:10.1016/j.celrep.2019.11.042 · Cited by 153 · cited 1×
“…of certain biomarkers which have never been reproduced by in situ staining; one example is CD5, shown by RNA and protein on conventional dendritic cells type 2 (cDC2) by high dimensional analysis (51 – 57) but not on tissue with in situ IF (Wood et al. (58) and manuscript in preparation).”
BackgroundStrategies for Accurate Cell Type Identification in CODEX Multiplexed Imaging Data
Hickey, J. W., Tan, Y., Nolan, G. P., & Goltsev, Y. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.727626 · Cited by 136 · cited 2×
“(29) Fourth, unlike Principal Component Analysis (PCA) which requires at least 2 dimensions, other DRAAPs do not have a minimum number of dimensions to identify meaningful relationships among the data; however, the higher the number of dimensions/parameters provided, the better the discriminative…”
BackgroundMethodYin, X., Yu, H., Jin, X., Li, J., Guo, H., Shi, Q., Yin, Z., Xu, Y., Wang, X., Liu, R., et al. (2017) · The Journal of Immunology · doi:10.4049/jimmunol.1600193 · Cited by 132
Illuminating RNA biology through imaging
Le, P., Ahmed, N., & Yeo, G. W.-M. (2022) · Nature Cell Biology · doi:10.1038/s41556-022-00933-9 · Cited by 129
Ljosa, V., & Carpenter, A. E. (2009) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000603 · Cited by 122 · cited 1×
“IA tools development (13) has accompanied the production of images all along.”
BackgroundThe anatomy of single cell mass cytometry data
Olsen, L. R., Leipold, M. D., Pedersen, C. B., & Maecker, H. T. (2018) · Cytometry Part A · doi:10.1002/cyto.a.23621 · Cited by 116
Zhang, W., Li, I., Reticker-Flynn, N. E., Good, Z., Chang, S., Samusik, N., Saumyaa, S., Li, Y., Zhou, X., Liang, R., et al. (2022) · Nature Methods · doi:10.1038/s41592-022-01498-z · Cited by 108 · cited 1×
“(29,30) In BRAQUE ’ s preprocessing a mixture of normal distributions is fitted for each of the log-transformed markers, and then each normal component of the mixture is shrunk toward its mean to help further steps counter this continuity and lack of clear separation.”
BackgroundEnhanced validation of antibodies for research applications
Edfors, F., Hober, A., Linderbäck, K., Maddalo, G., Azimi, A., Sivertsson, Å., Tegel, H., Hober, S., Szigyarto, C. A.-K., Fagerberg, L., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-06642-y · Cited by 104
Phillips, D., Schürch, C. M., Khodadoust, M. S., Kim, Y. H., Nolan, G. P., & Jiang, S. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.687673 · Cited by 104 · cited 1×
“The staining pattern of in-house CK staining of the lymph node reproduced what was obtained from the CODEX dataset, including the follicular B cell staining (Figure 7b).”
Highly multiplexed tissue imaging using repeated oligonucleotide exchange reaction
Kennedy‐Darling, J., Bhate, S. S., Hickey, J. W., Black, S., Barlow, G. L., Vazquez, G., Venkataraaman, V. G., Samusik, N., Goltsev, Y., Schürch, C. M., et al. (2021) · European Journal of Immunology · doi:10.1002/eji.202048891 · Cited by 103 · cited 1×
“(36) In the panel, a widely used “ pan keratin ” antibody cocktail, AE1 and AE3 (37) was used.”
MethodCellSighter: a neural network to classify cells in highly multiplexed images
Amitay, Y., Bussi, Y., Feinstein, B., Bagon, S., Milo, I., & Keren, L. (2023) · Nature Communications · doi:10.1038/s41467-023-40066-7 · Cited by 101 · cited 1×
“We also found that the granular analytical power of recent bioinformatic pipelines can extract information from images which defy human eye perception and deliver information unattainable with existing image analysis tools for single-stain images.”
BackgroundBiological versus electronic adaptive coloration: how can one inform the other?
Kreit, E., Mäthger, L. M., Hanlon, R. T., Dennis, P. B., Naik, R. R., Forsythe, E., & Heikenfeld, J. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2012.0601 · Cited by 100 · cited 2×
“From these experiments, we conclude that the discriminative power of the human eye for details along a 8 bit luminance scale is significantly reduced, compared to the available range.”
Algorithmic Tools for Mining High-Dimensional Cytometry Data
Chester, C., & Maecker, H. T. (2015) · The Journal of Immunology · doi:10.4049/jimmunol.1500633 · Cited by 96 · cited 1×
“The staining pattern of in-house CK staining of the lymph node reproduced what was obtained from the CODEX dataset, including the follicular B cell staining (Figure 7b).”
MethodSulczewski, F. B., Maqueda‐Alfaro, R. A., Alcántara‐Hernández, M., Perez, O. A., Saravanan, S., Yun, T. J., Seong, D., Hornero, R. A., Raquer-McKay, H. M., Esteva, E., et al. (2023) · Nature Immunology · doi:10.1038/s41590-023-01545-7 · Cited by 95 · cited 1×
“…of certain biomarkers which have never been reproduced by in situ staining; one example is CD5, shown by RNA and protein on conventional dendritic cells type 2 (cDC2) by high dimensional analysis (51 – 57) but not on tissue with in situ IF (Wood et al. (58) and manuscript in preparation).”
BackgroundAn updated guide for the perplexed: cytometry in the high-dimensional era
Liechti, T., Weber, L. M., Ashhurst, T. M., Stanley, N., Prlic, M., Gassen, S. V., & Mair, F. (2021) · Nature Immunology · doi:10.1038/s41590-021-01006-z · Cited by 95
Automated assignment of cell identity from single-cell multiplexed imaging and proteomic data
Geuenich, M. J., Hou, J., Sunyun, L., Ayub, S., Jackson, H. W., & Campbell, K. R. (2021) · Cell Systems · doi:10.1016/j.cels.2021.08.012 · Cited by 86
On the objectivity, reliability, and validity of deep learning enabled bioimage analyses
Segebarth, D., Griebel, M., Stein, N., von Collenberg, C. R., Martin, C., Fiedler, D., Comeras, L. B., Sah, A., Schoeffler, V., Lüffe, T., et al. (2020) · eLife · doi:10.7554/elife.59780 · Cited by 60 · cited 1×
“Manual gating (i.e. the application of a threshold/barrier discriminating two sets of variables) is considered the main source of data variability and inconsistency in FCM [8, 42, 43], but has never been addressed in tissue staining.”
BackgroundStoltzfus, C. R., Sivakumar, R., Kunz, L., Olin, B. E., Menietti, E., Speziale, D., Adelfio, R., Bacac, M., Colombetti, S., Perro, M., et al. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.726492 · Cited by 57
Towards foundation models of biological image segmentation
Ma, J., & Wang, B. (2023) · Nature Methods · doi:10.1038/s41592-023-01885-0 · Cited by 57 · cited 1×
“(15) However multiplex staining data are intrinsically so complex that deep learning-assisted IA has an increasing role in multiple steps, such as image segmentation, (16) data normalization, and cell classification.”
BackgroundComparative analysis of dimension reduction methods for cytometry by time-of-flight data
Wang, K., Yang, Y., Wu, F., Song, B., Wang, X., & Wang, T. (2023) · Nature Communications · doi:10.1038/s41467-023-37478-w · Cited by 53 · cited 2×
“Manual gating (i.e., the application of a threshold/barrier discriminating two sets of variables) is considered the main source of data variability and inconsistency in FCM, (8,42,43) but has never been addressed in tissue staining.”
BackgroundSmart microscopes of the future
Carpenter, A. E., Cimini, B. A., & Eliceiri, K. W. (2023) · Nature Methods · doi:10.1038/s41592-023-01912-0 · Cited by 46 · cited 1×
“(18) We sought to reevaluate the individual components leading to single-cell classification via hyperplexed stains, and in particular the role, when present, of a human visual assessment of images in processes such as assay sensitivity, antibody validation, signal thresholding, and gating and cell…”
BackgroundMultiple Iteractive Labeling by Antibody Neodeposition (MILAN)
Cattoretti, G., Cattoretti, G., Bosisio, F. M., Marcelis, L., & Bolognesi, M. M. (2018) · Protocol Exchange · doi:10.1038/protex.2018.106 · Cited by 39 · cited 1×
“…primary antibodies were applied overnight, washed in 50mM Tris-HCl buffer (pH 7.5) containing 0.01% Tween-20 (Merck) and 100 mM sucrose (TBS-Ts) [22], counterstained with a horseradish peroxidase–conjugated polymer (Vector Laboratories, Burlingame, CA, USA), washed, developed in DAB (Agilent,…”
MethodInfluentialSelf-citationAntibodies are forever: a study using 12–26‐year‐old expired antibodies
Argentieri, M. C., Pilla, D., Vanzati, A., Lonardi, S., Facchetti, F., Doglioni, C., Parravicini, C., & Cattoretti, G. (2013) · Histopathology · doi:10.1111/his.12225 · Cited by 36 · cited 1×
“We applied to the HubMap dataset BRAQUE, (19) a dimensionality reduction algorithms-based analytical pipeline (DRAAP) designed for the spatial Ab-based proteomic data in multiplex, which do not requires pre-definition of positive signal thresholds.”
Self-citationJarosch, S., Köhlen, J., Sarker, R. S. J., Steiger, K., Janssen, K., Christians, A., Hennig, C., Holler, E., D’Ippolito, E., & Busch, D. H. (2021) · Cell Reports Methods · doi:10.1016/j.crmeth.2021.100104 · Cited by 35
Girard, M., Law, J. C., Edilova, M. I., & Watts, T. H. (2020) · Science Immunology · doi:10.1126/sciimmunol.abe0347 · Cited by 32
2020 BioImage Analysis Survey: Community experiences and needs for the future
Jamali, N., Dobson, E. T. A., Eliceiri, K. W., Carpenter, A. E., & Cimini, B. A. (2021) · Biological Imaging · doi:10.1017/s2633903x21000039 · Cited by 30 · cited 1×
“Interestingly, one of the main concern of scientists using IA is to identify nuclei in sections [14], something Surgical Pathologists do effortlessly every day.”
BackgroundLinden, M. D., & Zarbo, R. J. (2001) · Applied immunohistochemistry & molecular morphology · doi:10.1097/00129039-200112000-00002 · Cited by 29 · cited 1×
“(38) The presence of a panCK reagent in the dataset made a comparison of the detection power possible between single-stains and hyperplexed images, by enumerating the positive cell types.”
Next-Generation Pathology by Multiplexed Immunohistochemistry
Smet, F. D., Antoranz, A., & Bosisio, F. M. (2020) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2020.09.009 · Cited by 29 · cited 1×
“We found that the human eye has a reduced discriminative power for grayscale and luminance levels compared to the 8-bit available spectrum, affecting positive signal recognition above the noise.”
The Adaptive and Innate Immune Cell Landscape of Uterine Leiomyosarcomas
Manzoni, M., Bolognesi, M. M., Antoranz, A., Mancari, R., Carinelli, S. G., Faretta, M., Bosisio, F. M., & Cattoretti, G. (2020) · Scientific Reports · doi:10.1038/s41598-020-57627-1 · Cited by 27
Self-citationQuantitation of oncogene products by computer-assisted image analysis and flow cytometry.
Czerniak, B. A., Herz, F., Wersto, R. P., Alster, P., Puszkin, E., Schwarz, E., & Koss, L. G. (1990) · Journal of Histochemistry & Cytochemistry · doi:10.1177/38.4.1969431 · Cited by 25 · cited 1×
“(15) However multiplex staining data are intrinsically so complex that deep learning-assisted IA has an increasing role in multiple steps, such as image segmentation, (16) data normalization, and cell classification.”
BackgroundCD5 monoclonal antibodies react with human peripheral blood dendritic cells.
Wood, G. S., & Freudenthal, P. S. (1992) · PubMed · Cited by 22
Multiple Iterative Labeling by Antibody Neodeposition (MILAN)Preprint
Cattoretti, G., Bosisio, F. M., Marcelis, L., et al. (2019) · Research Square · doi:10.21203/rs.2.1646/v4 · Cited by 20
Self-citationSynthetic Antigen Gels as Practical Controls for Standardized and Quantitative Immunohistochemistry
Hötzel, K. J., Havnar, C. A., Ngu, H., Rost, S., Liu, S. D., Rangell, L. K., & Peale, F. V., Jr. (2019) · Journal of Histochemistry & Cytochemistry · doi:10.1369/0022155419832002 · Cited by 13 · cited 1×
“As previously published by others, (34,35) TSA was not superior, compared to DAB, and as good as double indirect IF (20) for some fluorochromes (Figure 4).”
BackgroundWillenbrock, K., Renné, C., Rottenkolber, M., Klapper, W., Dreyling, M. H., Engelhard, M., Küppers, R., Hansmann, M., & Jungnickel, B. (2009) · Histopathology · doi:10.1111/j.1365-2559.2009.03241.x · Cited by 10 · cited 1×
“Another example is AID, the enzyme required in the nucleus to perform DNA alterations, which for some time has been detected only in the cytoplasm (59) and still not detected (60) in the presence of the RNA message.”
BackgroundFuria, L., Pelicci, S., Perillo, F., Bolognesi, M. M., Pelicci, P. G., Facciotti, F., Cattoretti, G., & Faretta, M. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.960734 · Cited by 10 · cited 1×
“By optimizing the staining conditions (41) and enhancing the image contrast, numerous AE3+ cells co-localize with a LMW KRTstaining (Figure 7c), in addition to other stained cells.”
BackgroundSelf-citationKang, Z., Szabo, A., Farago, T., Pérez‐Villatoro, F., Junquera, A., Saundarya, S., Launonen, I.-M. P., Anttila, E., Casado, J., Elias, K. M., et al. (2025) · Bioinformatics · doi:10.1093/bioinformatics/btaf082 · Cited by 9 · cited 1×
“Notices about the limitation of an eye-guided approach in high-dimensional studies have just begun to appear in the specialized literature [63, 64].”
BackgroundAntibodies Validated for Routinely Processed Tissues Stain Frozen Sections Unpredictably
Bolognesi, M. M., Mascadri, F., Perego, R., Bombelli, S., Bosisio, F. M., & Cattoretti, G. (2021) · BioTechniques · doi:10.2144/btn-2020-0149 · Cited by 7 · cited 2×
“The staining pattern of in-house CK staining of the lymph node reproduced what was obtained from the CODEX dataset, including the follicular B cell staining (Figure 7b).”
Self-citationMascadri, F., Bolognesi, M. M., Pilla, D., & Cattoretti, G. (2021) · Journal of Histochemistry & Cytochemistry · doi:10.1369/00221554211047287 · Cited by 7 · cited 1×
“The Alexa Fluor ™ 647 signal was acquired with a 650/13 nm excitation filter, a 694/44 nm emission filter, and a dichroic FF655-Di01 filter (24) and could be combined with other fluorochrome combinations except the ones emitting in the 530 – 570 nm range, where the TSA-Alexa FluorTM 647 product…”
MethodSelf-citationBRAQUE: Bayesian Reduction for Amplified Quantization in UMAP Embedding
Dall’Olio, L., Bolognesi, M. M., Borghesi, S., Cattoretti, G., & Castellani, G. (2023) · Entropy · doi:10.3390/e25020354 · Cited by 6 · cited 3×
“The staining pattern of in-house CK staining of the lymph node reproduced what was obtained from the CODEX dataset, including the follicular B cell staining (Figure 7b).”
Self-citationKang, Z., Szabo, A., Farago, T., et al. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.03.13.584767 · Cited by 6
Background-free Detection of Mouse Antibodies on Mouse Tissue by Anti-isotype Secondary Antibodies
Mascadri, F., Ciccimarra, R., Bolognesi, M. M., Stellari, F. F., Ravanetti, F., & Cattoretti, G. (2021) · Journal of Histochemistry & Cytochemistry · doi:10.1369/00221554211033239 · Cited by 4 · cited 1×
“Serial LN sections were immunostained for the AE1 – AE3 pre-made cocktail in a Omnis automated immunostainer (Agilent, Santa Clara, CA) with routine same-day protocols.”
Self-citationHolman, D., Rubin, S. J. S., Ferenc, M., Holman, E. A., Koron, A. N., Daniel, R., Boland, B. S., Nolan, G. P., Chang, J. T., & Rogalla, S. (2024) · Scientific Reports · doi:10.1038/s41598-024-68397-5 · Cited by 3
Cited by
(2025) · doi:10.1038/s41423-025-01313-7 · Cited by 97
“This increasing dimensionality in digital images further stimulates the development of advanced tools for image analyses and data extraction that go beyond what the experimenter ’ s eye, which is perhaps unconsciously biased but surely biologically limited, may see [345].”
Spatial transcriptomics: challenges and future directions in musculoskeletal diseases
Santos, K. D., Rockel, J. S., & Kapoor, M. (2025) · Current Opinion in Rheumatology · doi:10.1097/bor.0000000000001140 · Cited by 10
Bolognesi, M. M., Dall’Olio, L., Mandelli, G. E., Lorenzi, L., Bosisio, F. M., Haberman, A. M., Bhagat, G., Borghesi, S., Faretta, M., Castellani, G., et al. (2026) · PLOS One · doi:10.1371/journal.pone.0346693 · Cited by 2
“Lastly, BRAQUE scores as statistically relevant values not appreciable by signal thresholding and/or visual assessment [105].”
InfluentialSelf-citationBolognesi, M. M., Dall’Olio, L., Mandelli, G. E., Lorenzi, L., Bosisio, F. M., Haberman, A. M., Bhagat, G., Borghesi, S., Faretta, M., Castellani, G., et al. (2025) · doi:10.1101/2025.10.19.683341 · Cited by 2
Self-citation
Metadata
- Authors
- Bolognesi, M. M., Dall’Olio, L., Maerten, A., Borghesi, S., Castellani, G., & Cattoretti, G.
- Affiliations
- Institute of Molecular Bioimaging and Physiology (IT)
- Istituto delle Scienze Neurologiche di Bologna (IT)
- Vrije Universiteit Brussel (BE)
- University of Milano-Bicocca (IT)
- University of Bologna (IT)
- Corresponding author
- Cattoretti, Giorgio
- ORCID
- Venue
- Biological Imaging
- Publisher
- Cambridge University Press (CUP)
- Published
- 2024
- Volume
- 4
- Pages
- e10-e10
- ISSN
- 2633-903X (ISSN-L)
- PMC
- PMC11503829
- OpenAlex
- W4403694216
- Semantic Scholar
- 32141151dd12d741f175c89854e7370186ca7000
- Cited by
- 3
- References
- 70
- Citations by year
- 2026: 1 · 2025: 2
- FWCI
- 0.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Biological Imaging (publishedVersion, cc-by)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- Associazione Italiana per la Ricerca sul Cancro
- Regione Lombardia (2014–2020)
- European Regional Development Fund (2014-2020’)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Single-cell and spatial transcriptomics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- visual perception, image segmentation, signal thresholding, antibody validation, antibody specificity, Braque, signal-to-noise ratio, lymph nodes, histological image analysis, visual bias
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.