The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Modification of Indium Tin Oxide Electrodes with Nucleic Acids: Detection of Attomole Quantities of Immobilized DNA by Electrocatalysis
Abstract
Indium tin oxide electrodes were modified with DNA, and the guanines in the immobilized nucleic acid were used as a substrate for electrocatalytic oxidation by Ru(bpy)3(3+) (bpy = 2,2'-bipyridine). Nucleic acids were deposited onto 12.6-mm2 electrodes from 9:1 DMF/water mixtures buffered with sodium acetate. The DNA appeared to denature in the presence of DMF, leading to adsorption of single-stranded DNA. The nucleic acid was not removed by vigorous washing or heating the electrodes in water, although incubation in phosphate buffer overnight liberated the adsorbed biomolecule. Acquisition of cyclic voltammograms or chronoamperomograms of Ru(bpy)3(2+) at the modified electrodes produced catalytic signals indicative of oxidation of the immobilized guanine by Ru(III). The electrocatalytic current was a linear function of the extent of modification with a slope of 0.5 microA/pmol of adsorbed guanine; integration of the current-time traces gave 2.2+/-0.4 electrons/guanine molecule. Use of long DNA strands therefore gave steep responses in terms of the quantity of adsorbed DNA strand. For example, electrodes modified with a 1497-bp PCR product from the HER-2 gene produced detectable catalytic currents when as little as 550 amol of strand was adsorbed, giving a sensitivity of 44 amol/mm2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Steenken, S., & Jovanovic, S. V. (1997) · Journal of the American Chemical Society · doi:10.1021/ja962255b · Cited by 1,450
Cited by
Fan, C., Plaxco, K. W., & Heeger, A. J. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1633515100 · Cited by 1,043
Molecular Catalysis of Electrochemical Reactions. Mechanistic Aspects
Savéant, J.-M. (2008) · Chemical Reviews · doi:10.1021/cr068079z · Cited by 978
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
The evolution of β-diketone or β-diketophenol ligands and related complexes
Vigato, P. A., Peruzzo, V., & Tamburini, S. (2009) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2008.07.013 · Cited by 329
Facile DNA immobilization on surfaces through a catecholamine polymer
Ham, H. O., Liu, Z., Lau, K. H. A., Lee, H., & Messersmith, P. B. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201005001 · Cited by 189
Metadata
- Authors
- Armistead, P. M., & Thorp, H. H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-07-11
- Volume
- 72
- Issue
- 16
- Pages
- 3764-3770
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2059305877
- Cited by
- 180
- References
- 1
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.