The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrochemical interrogation of conformational changes as a reagentless method for the sequence-specific detection of DNA
Open accessAbstract
We report a strategy for the reagentless transduction of DNA hybridization into a readily detectable electrochemical signal by means of a conformational change analogous to the optical molecular beacon approach. The strategy involves an electroactive, ferrocene-tagged DNA stem–loop structure that self-assembles onto a gold electrode by means of facile gold-thiol chemistry. Hybridization induces a large conformational change in this surface-confined DNA structure, which in turn significantly alters the electron-transfer tunneling distance between the electrode and the redoxable label. The resulting change in electron transfer efficiency is readily measured by cyclic voltammetry at target DNA concentrations as low as 10 pM. In contrast to existing optical approaches, an electrochemical DNA (E-DNA) sensor built on this strategy can detect femtomoles of target DNA without employing cumbersome and expensive optics, light sources, or photodetectors. In contrast to previously reported electrochemical approaches, the E-DNA sensor achieves this impressive sensitivity without the use of exogenous reagents and without sacrificing selectivity or reusability. The E-DNA sensor thus offers the promise of convenient, reusable detection of picomolar DNA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The importance of being unfolded
Plaxco, K. W., & Groβ, M. (1997) · Nature · doi:10.1038/386657a0 · Cited by 121
Self-citation
Cited by
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
A gold nanoparticle-based chronocoulometric DNA sensor for amplified detection of DNA
Zhang, J., Song, S., Wang, L., Pan, D., & Fan, C. (2007) · Nature Protocols · doi:10.1038/nprot.2007.419 · Cited by 473
Self-citationNucleic Acid Biosensors: Recent Advances and Perspectives
Du, Y., & Dong, S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04190 · Cited by 429
Kelley, S. O., Mirkin, C. A., Walt, D. R., Ismagilov, R. F., Toner, M., & Sargent, E. H. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.261 · Cited by 398
Triplex DNA Nanostructures: From Basic Properties to Applications
Hu, Y., Cecconello, A., Idili, A., Ricci, F., & Willner, I. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201701868 · Cited by 336
Metadata
- Authors
- Fan, C., Plaxco, K. W., & Heeger, A. J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2003-07-16
- Volume
- 100
- Issue
- 16
- Pages
- 9134-9137
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2035868441
- Cited by
- 1,043
- References
- 1
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical interrogation of conformational changes as a reagentless method for the sequence-specific detection of DNA. https://app.cochat.ai/papers/10.1073/pnas.1633515100
- The paper
- Fan, C., Plaxco, K. W., & Heeger, A. J. (2003). Electrochemical interrogation of conformational changes as a reagentless method for the sequence-specific detection of DNA. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1633515100
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.