Protein Concentration and Enzyme Digestion on Microbeads for MALDI-TOF Peptide Mass Mapping of Proteins from Dilute Solutions
The DOI matches its Crossref record.
Abstract
A method for generating peptide mass maps from dilute protein samples is presented. The method involves the concentration of proteins from aqueous solution by adsorption onto reversed-phase polymeric microbeads. These beads are then washed extensively to remove contaminants, after which the bound proteins are digested with trypsin. Analysis of the digestion products is performed by MALDI-TOF mass spectrometry following direct deposition of the beads on a MALDI target, along with the matrix solution. The procedure is demonstrated using solutions of cytochrome c, lysozyme, and bovine serum albumin. The results of these digests are compared to trypsin digestions of the protein samples without sample preconcentration. Comparative results are also presented for protein solutions contaminated with 2 M NaCl, 2 M urea, or sodium dodecyl sulfate at concentrations up to 0.02%. These results reveal that, with the microbead preconcentration procedure, peptide mass maps can routinely be generated from highly contaminated samples with a protein concentration of only 100 nM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sample preparation and digestion for proteomic analyses using spin filters
Manza, L. L., Stamer, S. L., Ham, A. L., Codreanu, S. G., & Liebler, D. C. (2005) · PROTEOMICS · doi:10.1002/pmic.200401063 · Cited by 382
Yu, Y.-Q., Gilar, M., Lee, P. J., Bouvier, E. S. P., & Gebler, J. C. (2003) · Analytical Chemistry · doi:10.1021/ac0346196 · Cited by 313
High-Affinity Capture of Proteins by Diamond Nanoparticles for Mass Spectrometric Analysis
Kong, X. L., Huang, L. C. L., Hsu, C.-M., Chen, W.-H., Han, C.-C., & Chang, H.-C. (2005) · Analytical Chemistry · doi:10.1021/ac048971a · Cited by 265
New Mass-Spectrometry-Compatible Degradable Surfactant for Tissue Proteomics
Chang, Y.-H., Gregorich, Z. R., Chen, A. J., Hwang, L., Guner, H., Yu, D., Zhang, J., & Ge, Y. (2015) · Journal of Proteome Research · doi:10.1021/pr5012679 · Cited by 80
The benefits (and misfortunes) of SDS in top-down proteomics
Kachuk, C., & Doucette, A. A. (2018) · Journal of Proteomics · doi:10.1016/j.jprot.2017.03.002 · Cited by 39
Self-citation
Metadata
- Authors
- Doucette, A., Craft, D., & Li, L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-06-17
- Volume
- 72
- Issue
- 14
- Pages
- 3355-3362
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1969847041
- Cited by
- 84
- References
- 0
- FWCI
- 2.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Protein Concentration and Enzyme Digestion on Microbeads for MALDI-TOF Peptide Mass Mapping of Proteins from Dilute Solutions. https://app.cochat.ai/papers/10.1021/ac000176j
- The paper
- Doucette, A., Craft, D., & Li, L. (2000). Protein Concentration and Enzyme Digestion on Microbeads for MALDI-TOF Peptide Mass Mapping of Proteins from Dilute Solutions. Analytical Chemistry. https://doi.org/10.1021/ac000176j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.